Cargando…

The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty

OBJECTIVES: Bone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulat...

Descripción completa

Detalles Bibliográficos
Autores principales: Cowie, R. M., Aiken, S. S., Cooper, J. J., Jennings, L. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6397326/
https://www.ncbi.nlm.nih.gov/pubmed/30915212
http://dx.doi.org/10.1302/2046-3758.82.BJR-2018-0146.R1
_version_ 1783399409195679744
author Cowie, R. M.
Aiken, S. S.
Cooper, J. J.
Jennings, L. M.
author_facet Cowie, R. M.
Aiken, S. S.
Cooper, J. J.
Jennings, L. M.
author_sort Cowie, R. M.
collection PubMed
description OBJECTIVES: Bone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulation. METHODS: A total of 18 fixed-bearing U2 total knee arthroplasty system implants (United Orthopedic Corp., Hsinchu, Taiwan) were used. Implants challenged with CS-BVF were compared with new implants (negative controls) and those intentionally scratched with a diamond stylus (positive controls) representative of severe surface damage (n = 6 for each experimental group). Three million cycles (MC) of experimental simulation were carried out to simulate a walking gait cycle. Wear of the ultra-high-molecular-weight polyethylene (UHMWPE) tibial inserts was measured gravimetrically, and damage to articulating surfaces was assessed using profilometry. RESULTS: There was no significant difference (p  >  0.05) between the wear rate of implants challenged with CS-BVF (3.3 mm(3)/MC (95% confidence interval (CI) 1.8 to 4.8)) and the wear rate of those not challenged (2.8 mm(3)/MC (95% CI 1.3 to 4.3)). However, scratching the cobalt-chrome (CoCr) significantly (p < 0.001) increased the wear rate (20.6 mm(3)/MC (95% CI 15.5 to 25.7)). The mean surface roughness of implants challenged with CS-BVF was equivalent to negative controls both after damage simulation (p = 0.98) and at the conclusion of the study (p = 0.28). CONCLUSION: When used close to articulating surfaces, a low-hardness, high-purity CS-BVF had no influence on wear. When trapped between the articulating surfaces of a total knee arthroplasty, CS-BVF did not scratch the surface of CoCr femoral components, nor did it increase the wear of UHMWPE tibial inserts compared with undamaged negative controls. Cite this article: R. M. Cowie, S. S. Aiken, J. J. Cooper, L. M. Jennings. The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty. Bone Joint Res 2019;8:65–72. DOI: 10.1302/2046-3758.82.BJR-2018-0146.R1.
format Online
Article
Text
id pubmed-6397326
institution National Center for Biotechnology Information
language English
publishDate 2019
record_format MEDLINE/PubMed
spelling pubmed-63973262019-03-26 The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty Cowie, R. M. Aiken, S. S. Cooper, J. J. Jennings, L. M. Bone Joint Res Knee OBJECTIVES: Bone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulation. METHODS: A total of 18 fixed-bearing U2 total knee arthroplasty system implants (United Orthopedic Corp., Hsinchu, Taiwan) were used. Implants challenged with CS-BVF were compared with new implants (negative controls) and those intentionally scratched with a diamond stylus (positive controls) representative of severe surface damage (n = 6 for each experimental group). Three million cycles (MC) of experimental simulation were carried out to simulate a walking gait cycle. Wear of the ultra-high-molecular-weight polyethylene (UHMWPE) tibial inserts was measured gravimetrically, and damage to articulating surfaces was assessed using profilometry. RESULTS: There was no significant difference (p  >  0.05) between the wear rate of implants challenged with CS-BVF (3.3 mm(3)/MC (95% confidence interval (CI) 1.8 to 4.8)) and the wear rate of those not challenged (2.8 mm(3)/MC (95% CI 1.3 to 4.3)). However, scratching the cobalt-chrome (CoCr) significantly (p < 0.001) increased the wear rate (20.6 mm(3)/MC (95% CI 15.5 to 25.7)). The mean surface roughness of implants challenged with CS-BVF was equivalent to negative controls both after damage simulation (p = 0.98) and at the conclusion of the study (p = 0.28). CONCLUSION: When used close to articulating surfaces, a low-hardness, high-purity CS-BVF had no influence on wear. When trapped between the articulating surfaces of a total knee arthroplasty, CS-BVF did not scratch the surface of CoCr femoral components, nor did it increase the wear of UHMWPE tibial inserts compared with undamaged negative controls. Cite this article: R. M. Cowie, S. S. Aiken, J. J. Cooper, L. M. Jennings. The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty. Bone Joint Res 2019;8:65–72. DOI: 10.1302/2046-3758.82.BJR-2018-0146.R1. 2019-03-02 /pmc/articles/PMC6397326/ /pubmed/30915212 http://dx.doi.org/10.1302/2046-3758.82.BJR-2018-0146.R1 Text en © 2019 Author(s) et al. This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC-BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.
spellingShingle Knee
Cowie, R. M.
Aiken, S. S.
Cooper, J. J.
Jennings, L. M.
The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty
title The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty
title_full The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty
title_fullStr The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty
title_full_unstemmed The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty
title_short The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty
title_sort influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6397326/
https://www.ncbi.nlm.nih.gov/pubmed/30915212
http://dx.doi.org/10.1302/2046-3758.82.BJR-2018-0146.R1
work_keys_str_mv AT cowierm theinfluenceofacalciumsulphatebonevoidfilleronthethirdbodydamageandpolyethylenewearoftotalkneearthroplasty
AT aikenss theinfluenceofacalciumsulphatebonevoidfilleronthethirdbodydamageandpolyethylenewearoftotalkneearthroplasty
AT cooperjj theinfluenceofacalciumsulphatebonevoidfilleronthethirdbodydamageandpolyethylenewearoftotalkneearthroplasty
AT jenningslm theinfluenceofacalciumsulphatebonevoidfilleronthethirdbodydamageandpolyethylenewearoftotalkneearthroplasty
AT cowierm influenceofacalciumsulphatebonevoidfilleronthethirdbodydamageandpolyethylenewearoftotalkneearthroplasty
AT aikenss influenceofacalciumsulphatebonevoidfilleronthethirdbodydamageandpolyethylenewearoftotalkneearthroplasty
AT cooperjj influenceofacalciumsulphatebonevoidfilleronthethirdbodydamageandpolyethylenewearoftotalkneearthroplasty
AT jenningslm influenceofacalciumsulphatebonevoidfilleronthethirdbodydamageandpolyethylenewearoftotalkneearthroplasty