Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient

OBJECTIVE: To describe a very unique case of two Descemet stripping automated endothelial keratoplasty (DSAEK) surgeries performed in both eyes of the same patient with an extremely different graft thickness and overall corneal thickness but with the same corrected distance visual acuity (CDVA) 2 ye...

Descripción completa

Detalles Bibliográficos
Autores principales: Spadea, Leopoldo, Tonti, Emanuele, Napolitano, Rita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6398396/
https://www.ncbi.nlm.nih.gov/pubmed/30881147
http://dx.doi.org/10.2147/IMCRJ.S192650
_version_ 1783399573856714752
author Spadea, Leopoldo
Tonti, Emanuele
Napolitano, Rita
author_facet Spadea, Leopoldo
Tonti, Emanuele
Napolitano, Rita
author_sort Spadea, Leopoldo
collection PubMed
description OBJECTIVE: To describe a very unique case of two Descemet stripping automated endothelial keratoplasty (DSAEK) surgeries performed in both eyes of the same patient with an extremely different graft thickness and overall corneal thickness but with the same corrected distance visual acuity (CDVA) 2 years after surgery. CASE PRESENTATION: A 75-year-old woman with bilateral bullous keratopathy (BK) was submitted to DSAEK surgeries in both eyes, first in right and after 6 months in left eye. CDVA was 20/160 in the right eye and 20/63 in the left eye. Corneal thickness evaluated by anterior segment optical coherence tomography was 569 µm in the right eye and 560 µm in the left eye. The root mean square (RMS) was 2.1 in the right and left eyes. Endothelial cell densities were not detectable in both eyes. The estimated precut donor graft thickness from eye bank was 250 and 40 µm in the right and in the left graft, respectively. Two years after surgery CDVA was 20/25 in both eyes. Corneal thickness was 633 µm with a lenticule thickness of 206 µm in the right eye and 439 µm with a lenticule thickness of 48 µm in the left eye. The RMS was 1.7 in the right eye and 1.4 in the left eye. Endothelial cell density was 2.272 cells/mm(2) in the right and 2.154 cells/mm(2) in the left eye. CONCLUSION: DSAEK was safe and effective in the treatment of BK. In our report, the visual outcome resulted to be poorly related either to donor graft thickness or to postoperative corneal thickness.
format Online
Article
Text
id pubmed-6398396
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-63983962019-03-16 Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient Spadea, Leopoldo Tonti, Emanuele Napolitano, Rita Int Med Case Rep J Case Report OBJECTIVE: To describe a very unique case of two Descemet stripping automated endothelial keratoplasty (DSAEK) surgeries performed in both eyes of the same patient with an extremely different graft thickness and overall corneal thickness but with the same corrected distance visual acuity (CDVA) 2 years after surgery. CASE PRESENTATION: A 75-year-old woman with bilateral bullous keratopathy (BK) was submitted to DSAEK surgeries in both eyes, first in right and after 6 months in left eye. CDVA was 20/160 in the right eye and 20/63 in the left eye. Corneal thickness evaluated by anterior segment optical coherence tomography was 569 µm in the right eye and 560 µm in the left eye. The root mean square (RMS) was 2.1 in the right and left eyes. Endothelial cell densities were not detectable in both eyes. The estimated precut donor graft thickness from eye bank was 250 and 40 µm in the right and in the left graft, respectively. Two years after surgery CDVA was 20/25 in both eyes. Corneal thickness was 633 µm with a lenticule thickness of 206 µm in the right eye and 439 µm with a lenticule thickness of 48 µm in the left eye. The RMS was 1.7 in the right eye and 1.4 in the left eye. Endothelial cell density was 2.272 cells/mm(2) in the right and 2.154 cells/mm(2) in the left eye. CONCLUSION: DSAEK was safe and effective in the treatment of BK. In our report, the visual outcome resulted to be poorly related either to donor graft thickness or to postoperative corneal thickness. Dove Medical Press 2019-02-27 /pmc/articles/PMC6398396/ /pubmed/30881147 http://dx.doi.org/10.2147/IMCRJ.S192650 Text en © 2019 Spadea et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Case Report
Spadea, Leopoldo
Tonti, Emanuele
Napolitano, Rita
Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient
title Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient
title_full Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient
title_fullStr Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient
title_full_unstemmed Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient
title_short Different graft thicknesses after Descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient
title_sort different graft thicknesses after descemet stripping endothelial keratoplasty for bullous keratopathy in the two eyes of the same patient
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6398396/
https://www.ncbi.nlm.nih.gov/pubmed/30881147
http://dx.doi.org/10.2147/IMCRJ.S192650
work_keys_str_mv AT spadealeopoldo differentgraftthicknessesafterdescemetstrippingendothelialkeratoplastyforbullouskeratopathyinthetwoeyesofthesamepatient
AT tontiemanuele differentgraftthicknessesafterdescemetstrippingendothelialkeratoplastyforbullouskeratopathyinthetwoeyesofthesamepatient
AT napolitanorita differentgraftthicknessesafterdescemetstrippingendothelialkeratoplastyforbullouskeratopathyinthetwoeyesofthesamepatient