Cargando…
Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices
BACKGROUND: Supraglottic airway devices (SADs) are an essential second line tool during difficult airway management after failed tracheal intubation. Particularly for such challenging situations the handling of an SAD requires sufficient training. We hypothesized that the feasibility of manikin-base...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6400128/ https://www.ncbi.nlm.nih.gov/pubmed/30881002 http://dx.doi.org/10.2147/TCRM.S194728 |
_version_ | 1783399895562977280 |
---|---|
author | Schmutz, Axel Bohn, Erich Spaeth, Johannes Heinrich, Sebastian |
author_facet | Schmutz, Axel Bohn, Erich Spaeth, Johannes Heinrich, Sebastian |
author_sort | Schmutz, Axel |
collection | PubMed |
description | BACKGROUND: Supraglottic airway devices (SADs) are an essential second line tool during difficult airway management after failed tracheal intubation. Particularly for such challenging situations the handling of an SAD requires sufficient training. We hypothesized that the feasibility of manikin-based airway management with second generation SADs depends on the type of manikin. METHODS: Two airway manikins (TruCorp AirSim(®) and Laerdal Resusci Anne(®) Airway Trainer™) were evaluated by 80 experienced anesthesia providers using 5 different second generation SADs (LMA(®) Supreme™ [LMA], Ambu(®) AuraGain™, i-gel(®), KOO™-SGA and LTS-D™). The primary outcome of the study was feasibility of ventilation measured by assessment of the manikins’ lung distention. As secondary outcome measures, oropharyngeal leakage pressure (OLP), ease of gastric tube insertion the insertion time, position and subjective assessments were evaluated. RESULTS: Ventilation was feasible with all combinations of SAD and manikin. By contrast, an OLP exceeding 10 cm H(2)O could be reached with most of the SADs in the TruCorp but with the LTS-D only in the Laerdal manikin. Gastric tube insertion was successful in above 90% in the Laerdal vs 87% in the TruCorp manikin (P<0.009). Insertion times differed significantly between manikins. The SAD positions were better in the Laerdal manikin for LMA, Ambu, i-gel and LTS-D. Participant’s assessments were superior in the Laerdal manikin for LMA, Ambu, i-gel and KOO-SGA. CONCLUSIONS: Ventilation is possible with all combinations. However, manikins are variable in their ability to adequately represent additional functions of second generation SADs. In order to achieve the best performance during training, the airway manikin should be chosen depending on the SAD in question. |
format | Online Article Text |
id | pubmed-6400128 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-64001282019-03-16 Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices Schmutz, Axel Bohn, Erich Spaeth, Johannes Heinrich, Sebastian Ther Clin Risk Manag Original Research BACKGROUND: Supraglottic airway devices (SADs) are an essential second line tool during difficult airway management after failed tracheal intubation. Particularly for such challenging situations the handling of an SAD requires sufficient training. We hypothesized that the feasibility of manikin-based airway management with second generation SADs depends on the type of manikin. METHODS: Two airway manikins (TruCorp AirSim(®) and Laerdal Resusci Anne(®) Airway Trainer™) were evaluated by 80 experienced anesthesia providers using 5 different second generation SADs (LMA(®) Supreme™ [LMA], Ambu(®) AuraGain™, i-gel(®), KOO™-SGA and LTS-D™). The primary outcome of the study was feasibility of ventilation measured by assessment of the manikins’ lung distention. As secondary outcome measures, oropharyngeal leakage pressure (OLP), ease of gastric tube insertion the insertion time, position and subjective assessments were evaluated. RESULTS: Ventilation was feasible with all combinations of SAD and manikin. By contrast, an OLP exceeding 10 cm H(2)O could be reached with most of the SADs in the TruCorp but with the LTS-D only in the Laerdal manikin. Gastric tube insertion was successful in above 90% in the Laerdal vs 87% in the TruCorp manikin (P<0.009). Insertion times differed significantly between manikins. The SAD positions were better in the Laerdal manikin for LMA, Ambu, i-gel and LTS-D. Participant’s assessments were superior in the Laerdal manikin for LMA, Ambu, i-gel and KOO-SGA. CONCLUSIONS: Ventilation is possible with all combinations. However, manikins are variable in their ability to adequately represent additional functions of second generation SADs. In order to achieve the best performance during training, the airway manikin should be chosen depending on the SAD in question. Dove Medical Press 2019-03-01 /pmc/articles/PMC6400128/ /pubmed/30881002 http://dx.doi.org/10.2147/TCRM.S194728 Text en © 2019 Schmutz et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Schmutz, Axel Bohn, Erich Spaeth, Johannes Heinrich, Sebastian Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices |
title | Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices |
title_full | Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices |
title_fullStr | Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices |
title_full_unstemmed | Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices |
title_short | Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices |
title_sort | comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6400128/ https://www.ncbi.nlm.nih.gov/pubmed/30881002 http://dx.doi.org/10.2147/TCRM.S194728 |
work_keys_str_mv | AT schmutzaxel comprehensiveevaluationofmanikinbasedairwaytrainingwithsecondgenerationsupraglotticairwaydevices AT bohnerich comprehensiveevaluationofmanikinbasedairwaytrainingwithsecondgenerationsupraglotticairwaydevices AT spaethjohannes comprehensiveevaluationofmanikinbasedairwaytrainingwithsecondgenerationsupraglotticairwaydevices AT heinrichsebastian comprehensiveevaluationofmanikinbasedairwaytrainingwithsecondgenerationsupraglotticairwaydevices |