Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter

BACKGROUND: It is very important to accurately enumerate CD34-positive (CD34+) cells for successful hematopoietic stem cell transplantation (HSCT). We evaluated the ability of the newly developed image based-immunofluorescence cell counter ADAMII (NanoEntek, Seoul, Korea) to enumerate CD34+ cells, w...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Haein, Yoo, Jaeeun, Hwang, Jung Sil, Kim, Mikyung, Bae, Kyung Hee, Jekarl, Dong Wook, Oh, Jong Hyun, Lee, Ji Yeon, Han, Sunmi, Chung, Chanil, Kim, Myungshin, Kim, Yonggoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6400716/
https://www.ncbi.nlm.nih.gov/pubmed/30809985
http://dx.doi.org/10.3343/alm.2019.39.4.388
_version_ 1783400012676333568
author Yu, Haein
Yoo, Jaeeun
Hwang, Jung Sil
Kim, Mikyung
Bae, Kyung Hee
Jekarl, Dong Wook
Oh, Jong Hyun
Lee, Ji Yeon
Han, Sunmi
Chung, Chanil
Kim, Myungshin
Kim, Yonggoo
author_facet Yu, Haein
Yoo, Jaeeun
Hwang, Jung Sil
Kim, Mikyung
Bae, Kyung Hee
Jekarl, Dong Wook
Oh, Jong Hyun
Lee, Ji Yeon
Han, Sunmi
Chung, Chanil
Kim, Myungshin
Kim, Yonggoo
author_sort Yu, Haein
collection PubMed
description BACKGROUND: It is very important to accurately enumerate CD34-positive (CD34+) cells for successful hematopoietic stem cell transplantation (HSCT). We evaluated the ability of the newly developed image based-immunofluorescence cell counter ADAMII (NanoEntek, Seoul, Korea) to enumerate CD34+ cells, which was improved through simultaneous CD45 analysis. METHODS: We enumerated CD34+ cells with ADAMII using 19 peripheral blood (PB) and 91 leukapheresis samples from HSCT donors. Analytical performance, including precision and linearity, was analyzed, and sample stability during storage was evaluated. Viable CD34+ cell count (vCD34) and viable CD45+ cell count (vCD45) and the percentage of viable CD34+ cells among viable CD45+ cells (CD34/CD45) as measured by ADAMII were compared with the corresponding values from two flow cytometry assays, using regression analysis. RESULTS: ADAMII demonstrated acceptable precision, as CV values of vCD34 from six samples with different counts were all <10% (range: 3.49–9.51%). CV values of the vCD45 and CD34/45 ranged from 4.03% to 9.67% and from 2.48% to 10.07%, respectively. The linearity of vCD34 showed an excellent R(2) value (0.99) when analyzed using the intended count and flow cytometry data. The ADAMII and two flow cytometry-based assays generated very similar data for the PB and leukapheresis samples. CONCLUSIONS: ADAMII demonstrated excellent performance for use as a routine clinical assay in terms of CD34+ cell enumeration from PB and leukapheresis samples. Moreover, it could be used as a point-of-care-test for determining mobilization time and predicting an adequate apheresis stem cell product.
format Online
Article
Text
id pubmed-6400716
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-64007162019-07-01 Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter Yu, Haein Yoo, Jaeeun Hwang, Jung Sil Kim, Mikyung Bae, Kyung Hee Jekarl, Dong Wook Oh, Jong Hyun Lee, Ji Yeon Han, Sunmi Chung, Chanil Kim, Myungshin Kim, Yonggoo Ann Lab Med Original Article BACKGROUND: It is very important to accurately enumerate CD34-positive (CD34+) cells for successful hematopoietic stem cell transplantation (HSCT). We evaluated the ability of the newly developed image based-immunofluorescence cell counter ADAMII (NanoEntek, Seoul, Korea) to enumerate CD34+ cells, which was improved through simultaneous CD45 analysis. METHODS: We enumerated CD34+ cells with ADAMII using 19 peripheral blood (PB) and 91 leukapheresis samples from HSCT donors. Analytical performance, including precision and linearity, was analyzed, and sample stability during storage was evaluated. Viable CD34+ cell count (vCD34) and viable CD45+ cell count (vCD45) and the percentage of viable CD34+ cells among viable CD45+ cells (CD34/CD45) as measured by ADAMII were compared with the corresponding values from two flow cytometry assays, using regression analysis. RESULTS: ADAMII demonstrated acceptable precision, as CV values of vCD34 from six samples with different counts were all <10% (range: 3.49–9.51%). CV values of the vCD45 and CD34/45 ranged from 4.03% to 9.67% and from 2.48% to 10.07%, respectively. The linearity of vCD34 showed an excellent R(2) value (0.99) when analyzed using the intended count and flow cytometry data. The ADAMII and two flow cytometry-based assays generated very similar data for the PB and leukapheresis samples. CONCLUSIONS: ADAMII demonstrated excellent performance for use as a routine clinical assay in terms of CD34+ cell enumeration from PB and leukapheresis samples. Moreover, it could be used as a point-of-care-test for determining mobilization time and predicting an adequate apheresis stem cell product. The Korean Society for Laboratory Medicine 2019-07 2019-02-26 /pmc/articles/PMC6400716/ /pubmed/30809985 http://dx.doi.org/10.3343/alm.2019.39.4.388 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yu, Haein
Yoo, Jaeeun
Hwang, Jung Sil
Kim, Mikyung
Bae, Kyung Hee
Jekarl, Dong Wook
Oh, Jong Hyun
Lee, Ji Yeon
Han, Sunmi
Chung, Chanil
Kim, Myungshin
Kim, Yonggoo
Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter
title Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter
title_full Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter
title_fullStr Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter
title_full_unstemmed Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter
title_short Enumeration of CD34-positive Stem Cells Using the ADAMII Image-based Fluorescence Cell Counter
title_sort enumeration of cd34-positive stem cells using the adamii image-based fluorescence cell counter
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6400716/
https://www.ncbi.nlm.nih.gov/pubmed/30809985
http://dx.doi.org/10.3343/alm.2019.39.4.388
work_keys_str_mv AT yuhaein enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT yoojaeeun enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT hwangjungsil enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT kimmikyung enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT baekyunghee enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT jekarldongwook enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT ohjonghyun enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT leejiyeon enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT hansunmi enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT chungchanil enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT kimmyungshin enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter
AT kimyonggoo enumerationofcd34positivestemcellsusingtheadamiiimagebasedfluorescencecellcounter