Cargando…

A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants

AIMS AND OBJECTIVE: Chemically modified and sandblasted acid-etched (SAE) mechanism leads to wettability of surfaces of dental implants which helps in osseointegration. The present study was conducted to determine the implant stability quotient (ISQ) of SAE and SAE chemically modified dental implant...

Descripción completa

Detalles Bibliográficos
Autores principales: Beena Kumary, TP, Parihar, Anuj Singh, Mathew, Joe, Sabu, K Ipe, Venkata, Sindhuja Kota, Babaji, Prashant
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6402250/
https://www.ncbi.nlm.nih.gov/pubmed/30923694
http://dx.doi.org/10.4103/jispcd.JISPCD_367_18
_version_ 1783400361192587264
author Beena Kumary, TP
Parihar, Anuj Singh
Mathew, Joe
Sabu, K Ipe
Venkata, Sindhuja Kota
Babaji, Prashant
author_facet Beena Kumary, TP
Parihar, Anuj Singh
Mathew, Joe
Sabu, K Ipe
Venkata, Sindhuja Kota
Babaji, Prashant
author_sort Beena Kumary, TP
collection PubMed
description AIMS AND OBJECTIVE: Chemically modified and sandblasted acid-etched (SAE) mechanism leads to wettability of surfaces of dental implants which helps in osseointegration. The present study was conducted to determine the implant stability quotient (ISQ) of SAE and SAE chemically modified dental implants. MATERIALS AND METHODS: The present study was conducted on 210 patients with 120 males and 90 females. Dental implants (Adin) with SAE (Group A) and SAE chemically modified (Group B) were inserted in patients. RFA was done immediately after implant insertion and after 1 week, 2 weeks, 6 weeks, 10 weeks, and 14 weeks. Results were statistically evaluated using SPSS Statistics for Windows, Version 21.0, IBM Corp., Armonk, NY, USA. RESULTS: Maximum patients were in the age group of 25–35 years (males – 65, females – 48), followed by 35–45 years (males – 40, females – 32) and 45–55 years (males – 15, females – 10). Maximum dental implants were given in the right side (88) in males than females (56). On the left side, maximum implants were given in females (62) than males (56). Maximum RFA value of 86.2 and minimum value of 44.6 were observed in SAE dental implants (A). The maximum mean RFA value in chemically modified implants SAE (B) was 89.4 and minimum was 32.5. CONCLUSION: It was observed that surface treatment of dental implants shows higher implant–bone osseointegration. There is fastest osseointegration in implants with hydrophilic surfaces than those with SAE surfaces. ISQ was higher than 75 in both groups, which indicate higher implant stability.
format Online
Article
Text
id pubmed-6402250
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-64022502019-03-28 A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants Beena Kumary, TP Parihar, Anuj Singh Mathew, Joe Sabu, K Ipe Venkata, Sindhuja Kota Babaji, Prashant J Int Soc Prev Community Dent Original Article AIMS AND OBJECTIVE: Chemically modified and sandblasted acid-etched (SAE) mechanism leads to wettability of surfaces of dental implants which helps in osseointegration. The present study was conducted to determine the implant stability quotient (ISQ) of SAE and SAE chemically modified dental implants. MATERIALS AND METHODS: The present study was conducted on 210 patients with 120 males and 90 females. Dental implants (Adin) with SAE (Group A) and SAE chemically modified (Group B) were inserted in patients. RFA was done immediately after implant insertion and after 1 week, 2 weeks, 6 weeks, 10 weeks, and 14 weeks. Results were statistically evaluated using SPSS Statistics for Windows, Version 21.0, IBM Corp., Armonk, NY, USA. RESULTS: Maximum patients were in the age group of 25–35 years (males – 65, females – 48), followed by 35–45 years (males – 40, females – 32) and 45–55 years (males – 15, females – 10). Maximum dental implants were given in the right side (88) in males than females (56). On the left side, maximum implants were given in females (62) than males (56). Maximum RFA value of 86.2 and minimum value of 44.6 were observed in SAE dental implants (A). The maximum mean RFA value in chemically modified implants SAE (B) was 89.4 and minimum was 32.5. CONCLUSION: It was observed that surface treatment of dental implants shows higher implant–bone osseointegration. There is fastest osseointegration in implants with hydrophilic surfaces than those with SAE surfaces. ISQ was higher than 75 in both groups, which indicate higher implant stability. Medknow Publications & Media Pvt Ltd 2019 2019-02-14 /pmc/articles/PMC6402250/ /pubmed/30923694 http://dx.doi.org/10.4103/jispcd.JISPCD_367_18 Text en Copyright: © 2019 Journal of International Society of Preventive and Community Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Beena Kumary, TP
Parihar, Anuj Singh
Mathew, Joe
Sabu, K Ipe
Venkata, Sindhuja Kota
Babaji, Prashant
A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants
title A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants
title_full A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants
title_fullStr A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants
title_full_unstemmed A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants
title_short A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants
title_sort clinical and radiographic evaluation of resonance frequency analysis of sand blasted acid etched (sae) and chemical modified sae dental implants
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6402250/
https://www.ncbi.nlm.nih.gov/pubmed/30923694
http://dx.doi.org/10.4103/jispcd.JISPCD_367_18
work_keys_str_mv AT beenakumarytp aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT pariharanujsingh aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT mathewjoe aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT sabukipe aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT venkatasindhujakota aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT babajiprashant aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT beenakumarytp clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT pariharanujsingh clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT mathewjoe clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT sabukipe clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT venkatasindhujakota clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants
AT babajiprashant clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants