Cargando…
A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants
AIMS AND OBJECTIVE: Chemically modified and sandblasted acid-etched (SAE) mechanism leads to wettability of surfaces of dental implants which helps in osseointegration. The present study was conducted to determine the implant stability quotient (ISQ) of SAE and SAE chemically modified dental implant...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6402250/ https://www.ncbi.nlm.nih.gov/pubmed/30923694 http://dx.doi.org/10.4103/jispcd.JISPCD_367_18 |
_version_ | 1783400361192587264 |
---|---|
author | Beena Kumary, TP Parihar, Anuj Singh Mathew, Joe Sabu, K Ipe Venkata, Sindhuja Kota Babaji, Prashant |
author_facet | Beena Kumary, TP Parihar, Anuj Singh Mathew, Joe Sabu, K Ipe Venkata, Sindhuja Kota Babaji, Prashant |
author_sort | Beena Kumary, TP |
collection | PubMed |
description | AIMS AND OBJECTIVE: Chemically modified and sandblasted acid-etched (SAE) mechanism leads to wettability of surfaces of dental implants which helps in osseointegration. The present study was conducted to determine the implant stability quotient (ISQ) of SAE and SAE chemically modified dental implants. MATERIALS AND METHODS: The present study was conducted on 210 patients with 120 males and 90 females. Dental implants (Adin) with SAE (Group A) and SAE chemically modified (Group B) were inserted in patients. RFA was done immediately after implant insertion and after 1 week, 2 weeks, 6 weeks, 10 weeks, and 14 weeks. Results were statistically evaluated using SPSS Statistics for Windows, Version 21.0, IBM Corp., Armonk, NY, USA. RESULTS: Maximum patients were in the age group of 25–35 years (males – 65, females – 48), followed by 35–45 years (males – 40, females – 32) and 45–55 years (males – 15, females – 10). Maximum dental implants were given in the right side (88) in males than females (56). On the left side, maximum implants were given in females (62) than males (56). Maximum RFA value of 86.2 and minimum value of 44.6 were observed in SAE dental implants (A). The maximum mean RFA value in chemically modified implants SAE (B) was 89.4 and minimum was 32.5. CONCLUSION: It was observed that surface treatment of dental implants shows higher implant–bone osseointegration. There is fastest osseointegration in implants with hydrophilic surfaces than those with SAE surfaces. ISQ was higher than 75 in both groups, which indicate higher implant stability. |
format | Online Article Text |
id | pubmed-6402250 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-64022502019-03-28 A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants Beena Kumary, TP Parihar, Anuj Singh Mathew, Joe Sabu, K Ipe Venkata, Sindhuja Kota Babaji, Prashant J Int Soc Prev Community Dent Original Article AIMS AND OBJECTIVE: Chemically modified and sandblasted acid-etched (SAE) mechanism leads to wettability of surfaces of dental implants which helps in osseointegration. The present study was conducted to determine the implant stability quotient (ISQ) of SAE and SAE chemically modified dental implants. MATERIALS AND METHODS: The present study was conducted on 210 patients with 120 males and 90 females. Dental implants (Adin) with SAE (Group A) and SAE chemically modified (Group B) were inserted in patients. RFA was done immediately after implant insertion and after 1 week, 2 weeks, 6 weeks, 10 weeks, and 14 weeks. Results were statistically evaluated using SPSS Statistics for Windows, Version 21.0, IBM Corp., Armonk, NY, USA. RESULTS: Maximum patients were in the age group of 25–35 years (males – 65, females – 48), followed by 35–45 years (males – 40, females – 32) and 45–55 years (males – 15, females – 10). Maximum dental implants were given in the right side (88) in males than females (56). On the left side, maximum implants were given in females (62) than males (56). Maximum RFA value of 86.2 and minimum value of 44.6 were observed in SAE dental implants (A). The maximum mean RFA value in chemically modified implants SAE (B) was 89.4 and minimum was 32.5. CONCLUSION: It was observed that surface treatment of dental implants shows higher implant–bone osseointegration. There is fastest osseointegration in implants with hydrophilic surfaces than those with SAE surfaces. ISQ was higher than 75 in both groups, which indicate higher implant stability. Medknow Publications & Media Pvt Ltd 2019 2019-02-14 /pmc/articles/PMC6402250/ /pubmed/30923694 http://dx.doi.org/10.4103/jispcd.JISPCD_367_18 Text en Copyright: © 2019 Journal of International Society of Preventive and Community Dentistry http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Beena Kumary, TP Parihar, Anuj Singh Mathew, Joe Sabu, K Ipe Venkata, Sindhuja Kota Babaji, Prashant A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants |
title | A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants |
title_full | A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants |
title_fullStr | A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants |
title_full_unstemmed | A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants |
title_short | A Clinical and Radiographic Evaluation of Resonance Frequency Analysis of Sand Blasted Acid Etched (SAE) and Chemical Modified Sae Dental Implants |
title_sort | clinical and radiographic evaluation of resonance frequency analysis of sand blasted acid etched (sae) and chemical modified sae dental implants |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6402250/ https://www.ncbi.nlm.nih.gov/pubmed/30923694 http://dx.doi.org/10.4103/jispcd.JISPCD_367_18 |
work_keys_str_mv | AT beenakumarytp aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT pariharanujsingh aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT mathewjoe aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT sabukipe aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT venkatasindhujakota aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT babajiprashant aclinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT beenakumarytp clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT pariharanujsingh clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT mathewjoe clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT sabukipe clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT venkatasindhujakota clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants AT babajiprashant clinicalandradiographicevaluationofresonancefrequencyanalysisofsandblastedacidetchedsaeandchemicalmodifiedsaedentalimplants |