Cargando…

Accuracy and Performance of Functional Parameter Estimation Using a Novel Numerical Optimization Approach for GPU-Based Kinetic Compartmental Modeling

Quantitative kinetic parameters derived from dynamic contrast-enhanced (DCE) data are dependent on signal measurement quality and choice of pharmacokinetic model. However, the fundamental optimization analysis method is equally important and its impact on pharmacokinetic parameters has been mostly o...

Descripción completa

Detalles Bibliográficos
Autores principales: Svistoun, Igor, Driscoll, Brandon, Coolens, Catherine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Grapho Publications, LLC 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6403032/
https://www.ncbi.nlm.nih.gov/pubmed/30854459
http://dx.doi.org/10.18383/j.tom.2018.00048
_version_ 1783400495464841216
author Svistoun, Igor
Driscoll, Brandon
Coolens, Catherine
author_facet Svistoun, Igor
Driscoll, Brandon
Coolens, Catherine
author_sort Svistoun, Igor
collection PubMed
description Quantitative kinetic parameters derived from dynamic contrast-enhanced (DCE) data are dependent on signal measurement quality and choice of pharmacokinetic model. However, the fundamental optimization analysis method is equally important and its impact on pharmacokinetic parameters has been mostly overlooked. We examine the effects of those choices on accuracy and performance of parameter estimation using both computer processing unit and graphical processing unit (GPU) numerical optimization implementations and evaluate the improvements offered by a novel optimization approach. A test framework was developed where experimentally derived population-average arterial input function and randomly sampled parameter sets {K(trans), K(ep), V(b), τ} were used to generate known tissue curves. Five numerical optimization algorithms were evaluated: sequential quadratic programming, downhill simplex (Nelder–Mead), pattern search, simulated annealing, and differential evolution. This was combined with various objective function implementation details: delay approximation, discretization and varying sampling rates. Then, impact of noise and CPU/GPU implementation was tested for speed and accuracy. Finally, the optimal method was compared to conventional implementation as applied to clinical DCE computed tomography. Nelder–Mead, differential evolution and sequential quadratic programming produced good results on clean and noisy input data outperforming simulated annealing and pattern search in terms of speed and accuracy in the respective order of 10(−8)%, 10(−7)%, and ×10(−6)%). A novel approach for DCE numerical optimization (infinite impulse response with fractional delay approximation) was implemented on GPU for speed increase of at least 2 orders of magnitude. Applied to clinical data, the magnitude of overall parameter error was <10%.
format Online
Article
Text
id pubmed-6403032
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Grapho Publications, LLC
record_format MEDLINE/PubMed
spelling pubmed-64030322019-03-08 Accuracy and Performance of Functional Parameter Estimation Using a Novel Numerical Optimization Approach for GPU-Based Kinetic Compartmental Modeling Svistoun, Igor Driscoll, Brandon Coolens, Catherine Tomography Research Articles Quantitative kinetic parameters derived from dynamic contrast-enhanced (DCE) data are dependent on signal measurement quality and choice of pharmacokinetic model. However, the fundamental optimization analysis method is equally important and its impact on pharmacokinetic parameters has been mostly overlooked. We examine the effects of those choices on accuracy and performance of parameter estimation using both computer processing unit and graphical processing unit (GPU) numerical optimization implementations and evaluate the improvements offered by a novel optimization approach. A test framework was developed where experimentally derived population-average arterial input function and randomly sampled parameter sets {K(trans), K(ep), V(b), τ} were used to generate known tissue curves. Five numerical optimization algorithms were evaluated: sequential quadratic programming, downhill simplex (Nelder–Mead), pattern search, simulated annealing, and differential evolution. This was combined with various objective function implementation details: delay approximation, discretization and varying sampling rates. Then, impact of noise and CPU/GPU implementation was tested for speed and accuracy. Finally, the optimal method was compared to conventional implementation as applied to clinical DCE computed tomography. Nelder–Mead, differential evolution and sequential quadratic programming produced good results on clean and noisy input data outperforming simulated annealing and pattern search in terms of speed and accuracy in the respective order of 10(−8)%, 10(−7)%, and ×10(−6)%). A novel approach for DCE numerical optimization (infinite impulse response with fractional delay approximation) was implemented on GPU for speed increase of at least 2 orders of magnitude. Applied to clinical data, the magnitude of overall parameter error was <10%. Grapho Publications, LLC 2019-03 /pmc/articles/PMC6403032/ /pubmed/30854459 http://dx.doi.org/10.18383/j.tom.2018.00048 Text en © 2019 The Authors. Published by Grapho Publications, LLC http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Articles
Svistoun, Igor
Driscoll, Brandon
Coolens, Catherine
Accuracy and Performance of Functional Parameter Estimation Using a Novel Numerical Optimization Approach for GPU-Based Kinetic Compartmental Modeling
title Accuracy and Performance of Functional Parameter Estimation Using a Novel Numerical Optimization Approach for GPU-Based Kinetic Compartmental Modeling
title_full Accuracy and Performance of Functional Parameter Estimation Using a Novel Numerical Optimization Approach for GPU-Based Kinetic Compartmental Modeling
title_fullStr Accuracy and Performance of Functional Parameter Estimation Using a Novel Numerical Optimization Approach for GPU-Based Kinetic Compartmental Modeling
title_full_unstemmed Accuracy and Performance of Functional Parameter Estimation Using a Novel Numerical Optimization Approach for GPU-Based Kinetic Compartmental Modeling
title_short Accuracy and Performance of Functional Parameter Estimation Using a Novel Numerical Optimization Approach for GPU-Based Kinetic Compartmental Modeling
title_sort accuracy and performance of functional parameter estimation using a novel numerical optimization approach for gpu-based kinetic compartmental modeling
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6403032/
https://www.ncbi.nlm.nih.gov/pubmed/30854459
http://dx.doi.org/10.18383/j.tom.2018.00048
work_keys_str_mv AT svistounigor accuracyandperformanceoffunctionalparameterestimationusinganovelnumericaloptimizationapproachforgpubasedkineticcompartmentalmodeling
AT driscollbrandon accuracyandperformanceoffunctionalparameterestimationusinganovelnumericaloptimizationapproachforgpubasedkineticcompartmentalmodeling
AT coolenscatherine accuracyandperformanceoffunctionalparameterestimationusinganovelnumericaloptimizationapproachforgpubasedkineticcompartmentalmodeling