Cargando…
Comparative analysis of toxicity reduction of wastewater in twelve industrial park wastewater treatment plants based on battery of toxicity assays
Wastewater treatment plants (WWTPs) in industrial parks provide centralized treatment for industrial and domestic wastewater. However, the information on toxicity reduction of wastewater and its correlation with treatment process in industrial park is limited. This study compared the toxicity reduct...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6403317/ https://www.ncbi.nlm.nih.gov/pubmed/30842527 http://dx.doi.org/10.1038/s41598-019-40154-z |
_version_ | 1783400570245087232 |
---|---|
author | Yu, Yue Wu, Bing Jiang, Linmiao Zhang, Xu-Xiang Ren, Hong-Qiang Li, Mei |
author_facet | Yu, Yue Wu, Bing Jiang, Linmiao Zhang, Xu-Xiang Ren, Hong-Qiang Li, Mei |
author_sort | Yu, Yue |
collection | PubMed |
description | Wastewater treatment plants (WWTPs) in industrial parks provide centralized treatment for industrial and domestic wastewater. However, the information on toxicity reduction of wastewater and its correlation with treatment process in industrial park is limited. This study compared the toxicity reduction of wastewater in 12 industrial park WWTPs based on battery of toxicity assays. Nine toxic endpoints involving microorganism, phytoplankton, zooplankton, plant and human cell lines were applied. All the influents of WWTPs induced high toxicities, which were significantly reduced after the treatments from 7 of the studied WWTPs. However, the effluents of five WWTPs induced higher toxicity in one or more toxic endpoints compared to the influents. This study also found that most of anaerobic-anoxic-oxic (A(2)/O)-based processes had good removal efficiency of wastewater toxicity, while the sequencing batch reactor (SBR)-based processes had the lowest removal efficiency. Moreover, low correlation coefficients were obtained among all toxic endpoints, indicating that battery of toxicity assays was necessary to completely characterize the toxicity and risk of wastewater in industrial parks. This study shed new lights to the toxicity reduction of wastewater and its correlation with treatment process, which is very useful for the design, management and operation of WWTPs in industrial parks. |
format | Online Article Text |
id | pubmed-6403317 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-64033172019-03-08 Comparative analysis of toxicity reduction of wastewater in twelve industrial park wastewater treatment plants based on battery of toxicity assays Yu, Yue Wu, Bing Jiang, Linmiao Zhang, Xu-Xiang Ren, Hong-Qiang Li, Mei Sci Rep Article Wastewater treatment plants (WWTPs) in industrial parks provide centralized treatment for industrial and domestic wastewater. However, the information on toxicity reduction of wastewater and its correlation with treatment process in industrial park is limited. This study compared the toxicity reduction of wastewater in 12 industrial park WWTPs based on battery of toxicity assays. Nine toxic endpoints involving microorganism, phytoplankton, zooplankton, plant and human cell lines were applied. All the influents of WWTPs induced high toxicities, which were significantly reduced after the treatments from 7 of the studied WWTPs. However, the effluents of five WWTPs induced higher toxicity in one or more toxic endpoints compared to the influents. This study also found that most of anaerobic-anoxic-oxic (A(2)/O)-based processes had good removal efficiency of wastewater toxicity, while the sequencing batch reactor (SBR)-based processes had the lowest removal efficiency. Moreover, low correlation coefficients were obtained among all toxic endpoints, indicating that battery of toxicity assays was necessary to completely characterize the toxicity and risk of wastewater in industrial parks. This study shed new lights to the toxicity reduction of wastewater and its correlation with treatment process, which is very useful for the design, management and operation of WWTPs in industrial parks. Nature Publishing Group UK 2019-03-06 /pmc/articles/PMC6403317/ /pubmed/30842527 http://dx.doi.org/10.1038/s41598-019-40154-z Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Yu, Yue Wu, Bing Jiang, Linmiao Zhang, Xu-Xiang Ren, Hong-Qiang Li, Mei Comparative analysis of toxicity reduction of wastewater in twelve industrial park wastewater treatment plants based on battery of toxicity assays |
title | Comparative analysis of toxicity reduction of wastewater in twelve industrial park wastewater treatment plants based on battery of toxicity assays |
title_full | Comparative analysis of toxicity reduction of wastewater in twelve industrial park wastewater treatment plants based on battery of toxicity assays |
title_fullStr | Comparative analysis of toxicity reduction of wastewater in twelve industrial park wastewater treatment plants based on battery of toxicity assays |
title_full_unstemmed | Comparative analysis of toxicity reduction of wastewater in twelve industrial park wastewater treatment plants based on battery of toxicity assays |
title_short | Comparative analysis of toxicity reduction of wastewater in twelve industrial park wastewater treatment plants based on battery of toxicity assays |
title_sort | comparative analysis of toxicity reduction of wastewater in twelve industrial park wastewater treatment plants based on battery of toxicity assays |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6403317/ https://www.ncbi.nlm.nih.gov/pubmed/30842527 http://dx.doi.org/10.1038/s41598-019-40154-z |
work_keys_str_mv | AT yuyue comparativeanalysisoftoxicityreductionofwastewaterintwelveindustrialparkwastewatertreatmentplantsbasedonbatteryoftoxicityassays AT wubing comparativeanalysisoftoxicityreductionofwastewaterintwelveindustrialparkwastewatertreatmentplantsbasedonbatteryoftoxicityassays AT jianglinmiao comparativeanalysisoftoxicityreductionofwastewaterintwelveindustrialparkwastewatertreatmentplantsbasedonbatteryoftoxicityassays AT zhangxuxiang comparativeanalysisoftoxicityreductionofwastewaterintwelveindustrialparkwastewatertreatmentplantsbasedonbatteryoftoxicityassays AT renhongqiang comparativeanalysisoftoxicityreductionofwastewaterintwelveindustrialparkwastewatertreatmentplantsbasedonbatteryoftoxicityassays AT limei comparativeanalysisoftoxicityreductionofwastewaterintwelveindustrialparkwastewatertreatmentplantsbasedonbatteryoftoxicityassays |