Cargando…

Evaluation of offset of conjunctival hyperemia induced by a Rho-kinase inhibitor; 0.4% Ripasudil ophthalmic solution clinical trial

Glaucoma leads to irreversible blindness. Numerous anti-glaucoma eye drops have been developed. Unfortunately, many patients with glaucoma still suffer from progressive visual disorders. Recently, ripasudil hydrochloride hydrate, a selective Rho-associated protein kinase inhibitor, was launched for...

Descripción completa

Detalles Bibliográficos
Autores principales: Sakamoto, Emi, Ishida, Waka, Sumi, Tamaki, Kishimoto, Tatsuma, Tada, Kentaro, Fukuda, Ken, Yoneda, Tsuyoshi, Kuroiwa, Hajime, Terao, Etsuko, Fujisawa, Yasuko, Nakakura, Shunsuke, Jian, Koji, Okumichi, Hideaki, Kiuchi, Yoshiaki, Fukushima, Atsuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6403378/
https://www.ncbi.nlm.nih.gov/pubmed/30842572
http://dx.doi.org/10.1038/s41598-019-40255-9
Descripción
Sumario:Glaucoma leads to irreversible blindness. Numerous anti-glaucoma eye drops have been developed. Unfortunately, many patients with glaucoma still suffer from progressive visual disorders. Recently, ripasudil hydrochloride hydrate, a selective Rho-associated protein kinase inhibitor, was launched for the treatment of glaucoma. However, adverse events, such as conjunctival hyperemia, are often noted in clinical trials using healthy subjects. Therefore, we investigated the onset, offset, and kinetic changes of conjunctival hyperemia induced by ripasudil ophthalmic solution in patients with open-angle glaucoma or ocular hypertension who had already been treated with anti-glaucoma eye drops other than ripasudil. Conjunctival hyperemia was evaluated by both clinical grading by 3 ophthalmic physicians and pixel coverage of conjunctival blood vessels determined by conjunctival hyperemia-analyzing software. Conjunctival hyperemia appeared within 10 min post-instillation in most of the participants. Clinical grade and pixel coverage increased significantly 10 min post-instillation and then decreased. In most of the participants, hyperemia resolved within 2 h. Median conjunctival hyperemia offset was 90 min. A tendency of monotonic increase was observed between clinical grade and pixel coverage. Taken altogether, hyperemia induced by ripasudil was transient in glaucoma patients who had already been treated with anti-glaucoma eye drops other than ripasudil.