Cargando…

Urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury

BACKGROUND: Assessment of adequacy of intermittent hemodialysis (IHD) is conventionally based upon urea kinetic models for calculation of single pool Kt/V(urea) (Kt/V), with 1.2 accepted as minimum adequate clearance for thrice weekly IHD. In the Acute Renal Failure Trial Network (ATN) Study, adequa...

Descripción completa

Detalles Bibliográficos
Autores principales: Liang, Kelly V., Zhang, Jane H., Palevsky, Paul M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6404330/
https://www.ncbi.nlm.nih.gov/pubmed/30841863
http://dx.doi.org/10.1186/s12882-019-1272-7
Descripción
Sumario:BACKGROUND: Assessment of adequacy of intermittent hemodialysis (IHD) is conventionally based upon urea kinetic models for calculation of single pool Kt/V(urea) (Kt/V), with 1.2 accepted as minimum adequate clearance for thrice weekly IHD. In the Acute Renal Failure Trial Network (ATN) Study, adequacy of IHD in patients with acute kidney injury (AKI) was assessed using Kt/V. However, equations for Kt/V require volume of distribution of urea, which is highly variable in AKI. Therefore, simpler methods are needed to assess adequacy of IHD in AKI. We assessed correlation of urea reduction ratio (URR) with Kt/V and determined URR thresholds corresponding to Kt/V values to determine if URR could be a simpler means to assess the delivered dose of IHD. METHODS: Using patients who received IHD for 2.5–6 h and with pre-dialysis BUN ≥20 mg/dL, we plotted URR against Kt/V. We determined URR thresholds (0.60 to 0.75) corresponding to Kt/V ≥ 1.2, 1.3, and 1.4. We generated receiver operating characteristic (ROC) curves for increasing URR values for each level of Kt/V to identify the corresponding thresholds of URR. RESULTS: There was strong correlation between URR and Kt/V. ROC curves comparing URR with Kt/V ≥ 1.2, 1.3, and 1.4 had area under the curves (AUC) of 0.99. Sensitivity and specificity of URR ≥0.67 for corresponding values of Kt/V ≥ 1.2 were 0.769 (95% CI: 0.745 to 0.793) and 0.999 (95% CI: 0.997 to 1.000), respectively and the sensitivity and specificity of URR ≥0.67 for corresponding values of Kt/V ≥ 1.4 were 0.998 (95% CI: 0.995 to 1.000) and 0.791 (95% CI: 0.771 to 0.811), respectively. CONCLUSIONS: Targeting a URR ≥0.67 provides a simplified means of assessing adequacy of IHD in patients with AKI. Use of URR will enhance ability to assess delivery of small solute clearance and improve adherence with clinical practice guidelines in AKI.