Cargando…
Urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury
BACKGROUND: Assessment of adequacy of intermittent hemodialysis (IHD) is conventionally based upon urea kinetic models for calculation of single pool Kt/V(urea) (Kt/V), with 1.2 accepted as minimum adequate clearance for thrice weekly IHD. In the Acute Renal Failure Trial Network (ATN) Study, adequa...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6404330/ https://www.ncbi.nlm.nih.gov/pubmed/30841863 http://dx.doi.org/10.1186/s12882-019-1272-7 |
_version_ | 1783400856668864512 |
---|---|
author | Liang, Kelly V. Zhang, Jane H. Palevsky, Paul M. |
author_facet | Liang, Kelly V. Zhang, Jane H. Palevsky, Paul M. |
author_sort | Liang, Kelly V. |
collection | PubMed |
description | BACKGROUND: Assessment of adequacy of intermittent hemodialysis (IHD) is conventionally based upon urea kinetic models for calculation of single pool Kt/V(urea) (Kt/V), with 1.2 accepted as minimum adequate clearance for thrice weekly IHD. In the Acute Renal Failure Trial Network (ATN) Study, adequacy of IHD in patients with acute kidney injury (AKI) was assessed using Kt/V. However, equations for Kt/V require volume of distribution of urea, which is highly variable in AKI. Therefore, simpler methods are needed to assess adequacy of IHD in AKI. We assessed correlation of urea reduction ratio (URR) with Kt/V and determined URR thresholds corresponding to Kt/V values to determine if URR could be a simpler means to assess the delivered dose of IHD. METHODS: Using patients who received IHD for 2.5–6 h and with pre-dialysis BUN ≥20 mg/dL, we plotted URR against Kt/V. We determined URR thresholds (0.60 to 0.75) corresponding to Kt/V ≥ 1.2, 1.3, and 1.4. We generated receiver operating characteristic (ROC) curves for increasing URR values for each level of Kt/V to identify the corresponding thresholds of URR. RESULTS: There was strong correlation between URR and Kt/V. ROC curves comparing URR with Kt/V ≥ 1.2, 1.3, and 1.4 had area under the curves (AUC) of 0.99. Sensitivity and specificity of URR ≥0.67 for corresponding values of Kt/V ≥ 1.2 were 0.769 (95% CI: 0.745 to 0.793) and 0.999 (95% CI: 0.997 to 1.000), respectively and the sensitivity and specificity of URR ≥0.67 for corresponding values of Kt/V ≥ 1.4 were 0.998 (95% CI: 0.995 to 1.000) and 0.791 (95% CI: 0.771 to 0.811), respectively. CONCLUSIONS: Targeting a URR ≥0.67 provides a simplified means of assessing adequacy of IHD in patients with AKI. Use of URR will enhance ability to assess delivery of small solute clearance and improve adherence with clinical practice guidelines in AKI. |
format | Online Article Text |
id | pubmed-6404330 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-64043302019-03-18 Urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury Liang, Kelly V. Zhang, Jane H. Palevsky, Paul M. BMC Nephrol Research Article BACKGROUND: Assessment of adequacy of intermittent hemodialysis (IHD) is conventionally based upon urea kinetic models for calculation of single pool Kt/V(urea) (Kt/V), with 1.2 accepted as minimum adequate clearance for thrice weekly IHD. In the Acute Renal Failure Trial Network (ATN) Study, adequacy of IHD in patients with acute kidney injury (AKI) was assessed using Kt/V. However, equations for Kt/V require volume of distribution of urea, which is highly variable in AKI. Therefore, simpler methods are needed to assess adequacy of IHD in AKI. We assessed correlation of urea reduction ratio (URR) with Kt/V and determined URR thresholds corresponding to Kt/V values to determine if URR could be a simpler means to assess the delivered dose of IHD. METHODS: Using patients who received IHD for 2.5–6 h and with pre-dialysis BUN ≥20 mg/dL, we plotted URR against Kt/V. We determined URR thresholds (0.60 to 0.75) corresponding to Kt/V ≥ 1.2, 1.3, and 1.4. We generated receiver operating characteristic (ROC) curves for increasing URR values for each level of Kt/V to identify the corresponding thresholds of URR. RESULTS: There was strong correlation between URR and Kt/V. ROC curves comparing URR with Kt/V ≥ 1.2, 1.3, and 1.4 had area under the curves (AUC) of 0.99. Sensitivity and specificity of URR ≥0.67 for corresponding values of Kt/V ≥ 1.2 were 0.769 (95% CI: 0.745 to 0.793) and 0.999 (95% CI: 0.997 to 1.000), respectively and the sensitivity and specificity of URR ≥0.67 for corresponding values of Kt/V ≥ 1.4 were 0.998 (95% CI: 0.995 to 1.000) and 0.791 (95% CI: 0.771 to 0.811), respectively. CONCLUSIONS: Targeting a URR ≥0.67 provides a simplified means of assessing adequacy of IHD in patients with AKI. Use of URR will enhance ability to assess delivery of small solute clearance and improve adherence with clinical practice guidelines in AKI. BioMed Central 2019-03-06 /pmc/articles/PMC6404330/ /pubmed/30841863 http://dx.doi.org/10.1186/s12882-019-1272-7 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Liang, Kelly V. Zhang, Jane H. Palevsky, Paul M. Urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury |
title | Urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury |
title_full | Urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury |
title_fullStr | Urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury |
title_full_unstemmed | Urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury |
title_short | Urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury |
title_sort | urea reduction ratio may be a simpler approach for measurement of adequacy of intermittent hemodialysis in acute kidney injury |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6404330/ https://www.ncbi.nlm.nih.gov/pubmed/30841863 http://dx.doi.org/10.1186/s12882-019-1272-7 |
work_keys_str_mv | AT liangkellyv ureareductionratiomaybeasimplerapproachformeasurementofadequacyofintermittenthemodialysisinacutekidneyinjury AT zhangjaneh ureareductionratiomaybeasimplerapproachformeasurementofadequacyofintermittenthemodialysisinacutekidneyinjury AT palevskypaulm ureareductionratiomaybeasimplerapproachformeasurementofadequacyofintermittenthemodialysisinacutekidneyinjury |