Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy

BACKGROUND: Left ventricular (LV) hemodynamic assessment has been sparsely performed in patients supported on continuous‐flow LV assist devices (cfLVADs). Insight into dynamic changes of left heart parameters during ramp studies may improve LV assist device optimization and evaluate pathology. METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: Rosenbaum, Andrew N., Frantz, Robert P., Kushwaha, Sudhir S., Stulak, John M., Maltais, Simon, Behfar, Atta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6405677/
https://www.ncbi.nlm.nih.gov/pubmed/30755070
http://dx.doi.org/10.1161/JAHA.118.010232
_version_ 1783401132345786368
author Rosenbaum, Andrew N.
Frantz, Robert P.
Kushwaha, Sudhir S.
Stulak, John M.
Maltais, Simon
Behfar, Atta
author_facet Rosenbaum, Andrew N.
Frantz, Robert P.
Kushwaha, Sudhir S.
Stulak, John M.
Maltais, Simon
Behfar, Atta
author_sort Rosenbaum, Andrew N.
collection PubMed
description BACKGROUND: Left ventricular (LV) hemodynamic assessment has been sparsely performed in patients supported on continuous‐flow LV assist devices (cfLVADs). Insight into dynamic changes of left heart parameters during ramp studies may improve LV assist device optimization and evaluate pathology. METHODS AND RESULTS: To complement right heart catheterization, a novel technique for left heart catheterization in patients with a cfLVAD was developed. Patients implanted with cfLVADs underwent hemodynamic ramp left heart catheterization and right heart catheterization with transthoracic echocardiography. Continuous aortic and LV pressures were measured along with right atrial, pulmonary artery, and pulmonary capillary wedge pressures. A novel index, the transaortic gradient (TAG) was established. Thirty eight patients with cfLVADs were evaluated at a median of 446 days (interquartile range, 183–742) after device implant. During left heart catheterization performed for hemodynamic optimization, drop‐in LV end‐diastolic pressure and pulmonary capillary wedge pressure were associated with a rise in TAG. A range was identified for TAG (20–40 mm Hg) as providing the most optimal level of hemodynamic offloading. Pathologic states deviated from normal responses to ramp. LV assist device thrombosis was associated with an inability to increase in TAG during speed ramp. Significant aortic insufficiency was associated with a marked increase in LV end‐diastolic pressure despite a concomitant decrease in pulmonary capillary wedge pressure with increasing LV assist device speeds. CONCLUSIONS: Inclusion of left heart catheterization to a typical right heart catheterization LV assist device ramp protocol imparted unique insights to optimize cfLVAD speeds in different clinical scenarios. A novel index, the TAG was defined and provided additional resolution to optimized offloading.
format Online
Article
Text
id pubmed-6405677
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-64056772019-03-19 Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy Rosenbaum, Andrew N. Frantz, Robert P. Kushwaha, Sudhir S. Stulak, John M. Maltais, Simon Behfar, Atta J Am Heart Assoc Original Research BACKGROUND: Left ventricular (LV) hemodynamic assessment has been sparsely performed in patients supported on continuous‐flow LV assist devices (cfLVADs). Insight into dynamic changes of left heart parameters during ramp studies may improve LV assist device optimization and evaluate pathology. METHODS AND RESULTS: To complement right heart catheterization, a novel technique for left heart catheterization in patients with a cfLVAD was developed. Patients implanted with cfLVADs underwent hemodynamic ramp left heart catheterization and right heart catheterization with transthoracic echocardiography. Continuous aortic and LV pressures were measured along with right atrial, pulmonary artery, and pulmonary capillary wedge pressures. A novel index, the transaortic gradient (TAG) was established. Thirty eight patients with cfLVADs were evaluated at a median of 446 days (interquartile range, 183–742) after device implant. During left heart catheterization performed for hemodynamic optimization, drop‐in LV end‐diastolic pressure and pulmonary capillary wedge pressure were associated with a rise in TAG. A range was identified for TAG (20–40 mm Hg) as providing the most optimal level of hemodynamic offloading. Pathologic states deviated from normal responses to ramp. LV assist device thrombosis was associated with an inability to increase in TAG during speed ramp. Significant aortic insufficiency was associated with a marked increase in LV end‐diastolic pressure despite a concomitant decrease in pulmonary capillary wedge pressure with increasing LV assist device speeds. CONCLUSIONS: Inclusion of left heart catheterization to a typical right heart catheterization LV assist device ramp protocol imparted unique insights to optimize cfLVAD speeds in different clinical scenarios. A novel index, the TAG was defined and provided additional resolution to optimized offloading. John Wiley and Sons Inc. 2019-02-13 /pmc/articles/PMC6405677/ /pubmed/30755070 http://dx.doi.org/10.1161/JAHA.118.010232 Text en © 2019 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Research
Rosenbaum, Andrew N.
Frantz, Robert P.
Kushwaha, Sudhir S.
Stulak, John M.
Maltais, Simon
Behfar, Atta
Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
title Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
title_full Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
title_fullStr Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
title_full_unstemmed Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
title_short Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
title_sort novel left heart catheterization ramp protocol to guide hemodynamic optimization in patients supported with left ventricular assist device therapy
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6405677/
https://www.ncbi.nlm.nih.gov/pubmed/30755070
http://dx.doi.org/10.1161/JAHA.118.010232
work_keys_str_mv AT rosenbaumandrewn novelleftheartcatheterizationrampprotocoltoguidehemodynamicoptimizationinpatientssupportedwithleftventricularassistdevicetherapy
AT frantzrobertp novelleftheartcatheterizationrampprotocoltoguidehemodynamicoptimizationinpatientssupportedwithleftventricularassistdevicetherapy
AT kushwahasudhirs novelleftheartcatheterizationrampprotocoltoguidehemodynamicoptimizationinpatientssupportedwithleftventricularassistdevicetherapy
AT stulakjohnm novelleftheartcatheterizationrampprotocoltoguidehemodynamicoptimizationinpatientssupportedwithleftventricularassistdevicetherapy
AT maltaissimon novelleftheartcatheterizationrampprotocoltoguidehemodynamicoptimizationinpatientssupportedwithleftventricularassistdevicetherapy
AT behfaratta novelleftheartcatheterizationrampprotocoltoguidehemodynamicoptimizationinpatientssupportedwithleftventricularassistdevicetherapy