Cargando…
Chromatic pupilloperimetry for objective diagnosis of Best vitelliform macular dystrophy
PURPOSE: To determine the pupil response of Best vitelliform macular dystrophy (BVMD) patients for focal blue and red light stimuli presented at 76 test points in a 16.2° visual field (VF) using a chromatic pupilloperimeter. METHODS: An observational study was conducted in 16 participants: 7 BVMD pa...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6407903/ https://www.ncbi.nlm.nih.gov/pubmed/30880907 http://dx.doi.org/10.2147/OPTH.S191486 |
_version_ | 1783401653678899200 |
---|---|
author | Ben Ner, Daniel Sher, Ifat Hamburg, Amit Mhajna, Mohamad O Chibel, Ron Derazne, Estela Sharvit-Ginon, Inbal Pras, Eran Newman, Hadas Levy, Jaime Khateb, Samer Sharon, Dror Rotenstreich, Ygal |
author_facet | Ben Ner, Daniel Sher, Ifat Hamburg, Amit Mhajna, Mohamad O Chibel, Ron Derazne, Estela Sharvit-Ginon, Inbal Pras, Eran Newman, Hadas Levy, Jaime Khateb, Samer Sharon, Dror Rotenstreich, Ygal |
author_sort | Ben Ner, Daniel |
collection | PubMed |
description | PURPOSE: To determine the pupil response of Best vitelliform macular dystrophy (BVMD) patients for focal blue and red light stimuli presented at 76 test points in a 16.2° visual field (VF) using a chromatic pupilloperimeter. METHODS: An observational study was conducted in 16 participants: 7 BVMD patients with a heterozygous BEST1 mutation and 9 similar-aged controls. All participants were tested for best-corrected visual acuity, chromatic pupilloperimetry and Humphrey perimetry. Percentage of pupil contraction (PPC), maximal pupil contraction velocity (MCV) and latency of MCV (LMCV) were determined. RESULTS: The mean PPC and MCV recorded in BVMD patients in response to red stimuli were lower by >2 standard errors (SEs) from the mean of controls in 47% and 43% of VF test points, respectively. The mean PPC and MCV recorded in the patients in response to blue stimuli were lower by >2 SEs from the mean of controls in 36% and 24% of VF test points, respectively. The patients’ mean and median MCV recorded in response to red light correlated with their Humphrey mean deviation score (r=−0.714, P=0.071 and r=−0.821, P=0.023, respectively) and visual acuity (r=0.709, P=0.074 and r=0.655, P=0.111, respectively). A substantially shorter mean LMCV was recorded in BVMD patients compared to controls in 54% and 93% of VF test points in response to red and blue light, respectively. Receiver operating characteristic analysis for LMCV in response to red light identified a test point at the center of the VF with high diagnostic accuracy (area under the curve of 0.94). CONCLUSION: Chromatic pupilloperimetry may potentially be used for objective noninvasive assessment of rod and cone cell function in different locations of the retina in BVMD patients. |
format | Online Article Text |
id | pubmed-6407903 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-64079032019-03-16 Chromatic pupilloperimetry for objective diagnosis of Best vitelliform macular dystrophy Ben Ner, Daniel Sher, Ifat Hamburg, Amit Mhajna, Mohamad O Chibel, Ron Derazne, Estela Sharvit-Ginon, Inbal Pras, Eran Newman, Hadas Levy, Jaime Khateb, Samer Sharon, Dror Rotenstreich, Ygal Clin Ophthalmol Original Research PURPOSE: To determine the pupil response of Best vitelliform macular dystrophy (BVMD) patients for focal blue and red light stimuli presented at 76 test points in a 16.2° visual field (VF) using a chromatic pupilloperimeter. METHODS: An observational study was conducted in 16 participants: 7 BVMD patients with a heterozygous BEST1 mutation and 9 similar-aged controls. All participants were tested for best-corrected visual acuity, chromatic pupilloperimetry and Humphrey perimetry. Percentage of pupil contraction (PPC), maximal pupil contraction velocity (MCV) and latency of MCV (LMCV) were determined. RESULTS: The mean PPC and MCV recorded in BVMD patients in response to red stimuli were lower by >2 standard errors (SEs) from the mean of controls in 47% and 43% of VF test points, respectively. The mean PPC and MCV recorded in the patients in response to blue stimuli were lower by >2 SEs from the mean of controls in 36% and 24% of VF test points, respectively. The patients’ mean and median MCV recorded in response to red light correlated with their Humphrey mean deviation score (r=−0.714, P=0.071 and r=−0.821, P=0.023, respectively) and visual acuity (r=0.709, P=0.074 and r=0.655, P=0.111, respectively). A substantially shorter mean LMCV was recorded in BVMD patients compared to controls in 54% and 93% of VF test points in response to red and blue light, respectively. Receiver operating characteristic analysis for LMCV in response to red light identified a test point at the center of the VF with high diagnostic accuracy (area under the curve of 0.94). CONCLUSION: Chromatic pupilloperimetry may potentially be used for objective noninvasive assessment of rod and cone cell function in different locations of the retina in BVMD patients. Dove Medical Press 2019-03-05 /pmc/articles/PMC6407903/ /pubmed/30880907 http://dx.doi.org/10.2147/OPTH.S191486 Text en © 2019 Ben Ner et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Ben Ner, Daniel Sher, Ifat Hamburg, Amit Mhajna, Mohamad O Chibel, Ron Derazne, Estela Sharvit-Ginon, Inbal Pras, Eran Newman, Hadas Levy, Jaime Khateb, Samer Sharon, Dror Rotenstreich, Ygal Chromatic pupilloperimetry for objective diagnosis of Best vitelliform macular dystrophy |
title | Chromatic pupilloperimetry for objective diagnosis of Best vitelliform macular dystrophy |
title_full | Chromatic pupilloperimetry for objective diagnosis of Best vitelliform macular dystrophy |
title_fullStr | Chromatic pupilloperimetry for objective diagnosis of Best vitelliform macular dystrophy |
title_full_unstemmed | Chromatic pupilloperimetry for objective diagnosis of Best vitelliform macular dystrophy |
title_short | Chromatic pupilloperimetry for objective diagnosis of Best vitelliform macular dystrophy |
title_sort | chromatic pupilloperimetry for objective diagnosis of best vitelliform macular dystrophy |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6407903/ https://www.ncbi.nlm.nih.gov/pubmed/30880907 http://dx.doi.org/10.2147/OPTH.S191486 |
work_keys_str_mv | AT bennerdaniel chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT sherifat chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT hamburgamit chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT mhajnamohamado chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT chibelron chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT derazneestela chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT sharvitginoninbal chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT praseran chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT newmanhadas chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT levyjaime chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT khatebsamer chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT sharondror chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy AT rotenstreichygal chromaticpupilloperimetryforobjectivediagnosisofbestvitelliformmaculardystrophy |