Cargando…

The Effect of Electrode Topography on the Magnetic Properties and MRI Application of Electrochemically-Deposited, Synthesized, Cobalt-Substituted Hydroxyapatite

Magnetic nanoparticles are used to enhance the image contrast of magnetic resonance imaging (MRI). However, the development of magnetic nanoparticles with a low dose/high image contrast and non-toxicity is currently a major challenge. In this study, cobalt-substituted hydroxyapatite nanoparticles de...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Wei-Chun, Chuang, Chun-Chao, Chang, Chen-Jung, Chiu, Ya-Hsu, Yan, Min, Tang, Cheng-Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6409796/
https://www.ncbi.nlm.nih.gov/pubmed/30717496
http://dx.doi.org/10.3390/nano9020200
_version_ 1783402069146730496
author Lin, Wei-Chun
Chuang, Chun-Chao
Chang, Chen-Jung
Chiu, Ya-Hsu
Yan, Min
Tang, Cheng-Ming
author_facet Lin, Wei-Chun
Chuang, Chun-Chao
Chang, Chen-Jung
Chiu, Ya-Hsu
Yan, Min
Tang, Cheng-Ming
author_sort Lin, Wei-Chun
collection PubMed
description Magnetic nanoparticles are used to enhance the image contrast of magnetic resonance imaging (MRI). However, the development of magnetic nanoparticles with a low dose/high image contrast and non-toxicity is currently a major challenge. In this study, cobalt-substituted hydroxyapatite nanoparticles deposited on titanium (Ti-CoHA) and cobalt-substituted hydroxyapatite nanoparticles deposited on titanium dioxide nanotubes (TNT-CoHA) were synthesized by the electrochemical deposition method. The particle sizes of Ti-CoHA and TNT-CoHA were 418.6 nm and 127.5 nm, respectively, as observed using FE-SEM. It was shown that CoHA can be obtained with a smaller particle size using a titanium dioxide nanotube (TNT) electrode plate. However, the particle size of TNT-CoHA is smaller than that of Ti-CoHA. The crystal size of the internal cobalt oxide of CoHA was calculated by using an XRD pattern. The results indicate that the crystal size of cobalt oxide in TNT-CoHA is larger than that of the cobalt oxide in Ti-CoHA. The larger crystal size of the cobalt oxide in TNT-CoHA makes the saturation magnetization (Ms) of TNT-CoHA 12.6 times higher than that of Ti-CoHA. The contrast in MRIs is related to the magnetic properties of the particles. Therefore, TNT-CoHA has good image contrast at low concentrations in T(2) images. The relaxivity coefficient of the CoHA was higher for TNT-CoHA (340.3 mM(−1)s(−1)) than Ti-CoHA (211.7 mM(−1)s(−1)), and both were higher than the commercial iron nanoparticles (103.0 mM(−1)s(−1)). We showed that the TNT substrate caused an increase in the size of the cobalt oxide crystal of TNT-CoHA, thus effectively improving the magnetic field strength and MRI image recognition. It was also shown that the relaxivity coefficient rose with the Ms. Evaluation of biocompatibility of CoHA using human osteosarcoma cells (MG63) indicated no toxic effects. On the other hand, CoHA had an excellent antibacterial effect, as shown by E. coli evaluation, and the effect of TNT-CoHA powder was higher than that of Ti-CoHA powder. In summary, TNT-CoHA deposited electrochemically on the TNT substrates can be considered as a potential candidate for the application as an MRI contrast agent. This paper is a comparative study of how different electrode plates affect the magnetic and MRI image contrast of cobalt-substituted hydroxyapatite (CoHA) nanomaterials.
format Online
Article
Text
id pubmed-6409796
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64097962019-03-11 The Effect of Electrode Topography on the Magnetic Properties and MRI Application of Electrochemically-Deposited, Synthesized, Cobalt-Substituted Hydroxyapatite Lin, Wei-Chun Chuang, Chun-Chao Chang, Chen-Jung Chiu, Ya-Hsu Yan, Min Tang, Cheng-Ming Nanomaterials (Basel) Article Magnetic nanoparticles are used to enhance the image contrast of magnetic resonance imaging (MRI). However, the development of magnetic nanoparticles with a low dose/high image contrast and non-toxicity is currently a major challenge. In this study, cobalt-substituted hydroxyapatite nanoparticles deposited on titanium (Ti-CoHA) and cobalt-substituted hydroxyapatite nanoparticles deposited on titanium dioxide nanotubes (TNT-CoHA) were synthesized by the electrochemical deposition method. The particle sizes of Ti-CoHA and TNT-CoHA were 418.6 nm and 127.5 nm, respectively, as observed using FE-SEM. It was shown that CoHA can be obtained with a smaller particle size using a titanium dioxide nanotube (TNT) electrode plate. However, the particle size of TNT-CoHA is smaller than that of Ti-CoHA. The crystal size of the internal cobalt oxide of CoHA was calculated by using an XRD pattern. The results indicate that the crystal size of cobalt oxide in TNT-CoHA is larger than that of the cobalt oxide in Ti-CoHA. The larger crystal size of the cobalt oxide in TNT-CoHA makes the saturation magnetization (Ms) of TNT-CoHA 12.6 times higher than that of Ti-CoHA. The contrast in MRIs is related to the magnetic properties of the particles. Therefore, TNT-CoHA has good image contrast at low concentrations in T(2) images. The relaxivity coefficient of the CoHA was higher for TNT-CoHA (340.3 mM(−1)s(−1)) than Ti-CoHA (211.7 mM(−1)s(−1)), and both were higher than the commercial iron nanoparticles (103.0 mM(−1)s(−1)). We showed that the TNT substrate caused an increase in the size of the cobalt oxide crystal of TNT-CoHA, thus effectively improving the magnetic field strength and MRI image recognition. It was also shown that the relaxivity coefficient rose with the Ms. Evaluation of biocompatibility of CoHA using human osteosarcoma cells (MG63) indicated no toxic effects. On the other hand, CoHA had an excellent antibacterial effect, as shown by E. coli evaluation, and the effect of TNT-CoHA powder was higher than that of Ti-CoHA powder. In summary, TNT-CoHA deposited electrochemically on the TNT substrates can be considered as a potential candidate for the application as an MRI contrast agent. This paper is a comparative study of how different electrode plates affect the magnetic and MRI image contrast of cobalt-substituted hydroxyapatite (CoHA) nanomaterials. MDPI 2019-02-03 /pmc/articles/PMC6409796/ /pubmed/30717496 http://dx.doi.org/10.3390/nano9020200 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lin, Wei-Chun
Chuang, Chun-Chao
Chang, Chen-Jung
Chiu, Ya-Hsu
Yan, Min
Tang, Cheng-Ming
The Effect of Electrode Topography on the Magnetic Properties and MRI Application of Electrochemically-Deposited, Synthesized, Cobalt-Substituted Hydroxyapatite
title The Effect of Electrode Topography on the Magnetic Properties and MRI Application of Electrochemically-Deposited, Synthesized, Cobalt-Substituted Hydroxyapatite
title_full The Effect of Electrode Topography on the Magnetic Properties and MRI Application of Electrochemically-Deposited, Synthesized, Cobalt-Substituted Hydroxyapatite
title_fullStr The Effect of Electrode Topography on the Magnetic Properties and MRI Application of Electrochemically-Deposited, Synthesized, Cobalt-Substituted Hydroxyapatite
title_full_unstemmed The Effect of Electrode Topography on the Magnetic Properties and MRI Application of Electrochemically-Deposited, Synthesized, Cobalt-Substituted Hydroxyapatite
title_short The Effect of Electrode Topography on the Magnetic Properties and MRI Application of Electrochemically-Deposited, Synthesized, Cobalt-Substituted Hydroxyapatite
title_sort effect of electrode topography on the magnetic properties and mri application of electrochemically-deposited, synthesized, cobalt-substituted hydroxyapatite
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6409796/
https://www.ncbi.nlm.nih.gov/pubmed/30717496
http://dx.doi.org/10.3390/nano9020200
work_keys_str_mv AT linweichun theeffectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT chuangchunchao theeffectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT changchenjung theeffectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT chiuyahsu theeffectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT yanmin theeffectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT tangchengming theeffectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT linweichun effectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT chuangchunchao effectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT changchenjung effectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT chiuyahsu effectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT yanmin effectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite
AT tangchengming effectofelectrodetopographyonthemagneticpropertiesandmriapplicationofelectrochemicallydepositedsynthesizedcobaltsubstitutedhydroxyapatite