Reliability of Chest Wall Mobility and Its Correlation with Lung Functions in Healthy Nonsmokers, Healthy Smokers, and Patients with COPD

Chest wall circumference measurements are common evaluation methods in clinical settings by therapists in order to obtain chest wall mobility. Previous published results have been conflicting, and there is a lot of variability in the method of testing, which needs testing in different conditions. Se...

Descripción completa

Detalles Bibliográficos
Autores principales: Reddy, Ravi S., Alahmari, Khalid A., Silvian, Paul S., Ahmad, Irshad A., Kakarparthi, Venkata Nagaraj, Rengaramanujam, Kanagaraj
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6410441/
https://www.ncbi.nlm.nih.gov/pubmed/30931074
http://dx.doi.org/10.1155/2019/5175949
_version_ 1783402248092516352
author Reddy, Ravi S.
Alahmari, Khalid A.
Silvian, Paul S.
Ahmad, Irshad A.
Kakarparthi, Venkata Nagaraj
Rengaramanujam, Kanagaraj
author_facet Reddy, Ravi S.
Alahmari, Khalid A.
Silvian, Paul S.
Ahmad, Irshad A.
Kakarparthi, Venkata Nagaraj
Rengaramanujam, Kanagaraj
author_sort Reddy, Ravi S.
collection PubMed
description Chest wall circumference measurements are common evaluation methods in clinical settings by therapists in order to obtain chest wall mobility. Previous published results have been conflicting, and there is a lot of variability in the method of testing, which needs testing in different conditions. Seventy subjects (25 healthy nonsmokers, 25 healthy smokers, and 20 COPD) aged between 18 and 70 years participated in the study. Upper and lower chest expansion (CE) measurements (2 levels) are performed with cloth inch tape. Intrarater (between day) and interrater (within-day) reliability of CE measurements was evaluated by two examiners. Lung function parameters, forced expiratory volume in first second (FEV1), forced vital capacity (FVC), FEV1/FVC, and vital capacity (VC) were measured using a computerized spirometer (Spiro lab 3). The intrarater reliability for upper and lower CE showed very good agreement with intraclass correlation (ICC) values between 0.90 and 0.93 for upper CE and 0.85 to 0.86 for lower CE. The interrater reliability for upper CE showed good to very good agreement with ICC values ranging between 0.78 and 0.83, and lower CE showed very good agreement with ICC values ranging between 0.82 and 0.84. Upper and lower CE showed a significant and positive correlation with all lung function parameters, with strong correlation with FEV1/FVC (r = 0.68). Upper and lower CE measurements with inch tape showed good intra- and interrater reliability and reproducibility in healthy nonsmokers, healthy smokers, and COPD subjects. Compared to upper, lower CE correlated well with the lung function parameters. Upper and lower CE may be more useful in clinical practice to evaluate chest mobility and to give indirect information on lung function but interpretation with caution is required when considering implementation into clinical setting.
format Online
Article
Text
id pubmed-6410441
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-64104412019-03-31 Reliability of Chest Wall Mobility and Its Correlation with Lung Functions in Healthy Nonsmokers, Healthy Smokers, and Patients with COPD Reddy, Ravi S. Alahmari, Khalid A. Silvian, Paul S. Ahmad, Irshad A. Kakarparthi, Venkata Nagaraj Rengaramanujam, Kanagaraj Can Respir J Research Article Chest wall circumference measurements are common evaluation methods in clinical settings by therapists in order to obtain chest wall mobility. Previous published results have been conflicting, and there is a lot of variability in the method of testing, which needs testing in different conditions. Seventy subjects (25 healthy nonsmokers, 25 healthy smokers, and 20 COPD) aged between 18 and 70 years participated in the study. Upper and lower chest expansion (CE) measurements (2 levels) are performed with cloth inch tape. Intrarater (between day) and interrater (within-day) reliability of CE measurements was evaluated by two examiners. Lung function parameters, forced expiratory volume in first second (FEV1), forced vital capacity (FVC), FEV1/FVC, and vital capacity (VC) were measured using a computerized spirometer (Spiro lab 3). The intrarater reliability for upper and lower CE showed very good agreement with intraclass correlation (ICC) values between 0.90 and 0.93 for upper CE and 0.85 to 0.86 for lower CE. The interrater reliability for upper CE showed good to very good agreement with ICC values ranging between 0.78 and 0.83, and lower CE showed very good agreement with ICC values ranging between 0.82 and 0.84. Upper and lower CE showed a significant and positive correlation with all lung function parameters, with strong correlation with FEV1/FVC (r = 0.68). Upper and lower CE measurements with inch tape showed good intra- and interrater reliability and reproducibility in healthy nonsmokers, healthy smokers, and COPD subjects. Compared to upper, lower CE correlated well with the lung function parameters. Upper and lower CE may be more useful in clinical practice to evaluate chest mobility and to give indirect information on lung function but interpretation with caution is required when considering implementation into clinical setting. Hindawi 2019-02-25 /pmc/articles/PMC6410441/ /pubmed/30931074 http://dx.doi.org/10.1155/2019/5175949 Text en Copyright © 2019 Ravi S. Reddy et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Reddy, Ravi S.
Alahmari, Khalid A.
Silvian, Paul S.
Ahmad, Irshad A.
Kakarparthi, Venkata Nagaraj
Rengaramanujam, Kanagaraj
Reliability of Chest Wall Mobility and Its Correlation with Lung Functions in Healthy Nonsmokers, Healthy Smokers, and Patients with COPD
title Reliability of Chest Wall Mobility and Its Correlation with Lung Functions in Healthy Nonsmokers, Healthy Smokers, and Patients with COPD
title_full Reliability of Chest Wall Mobility and Its Correlation with Lung Functions in Healthy Nonsmokers, Healthy Smokers, and Patients with COPD
title_fullStr Reliability of Chest Wall Mobility and Its Correlation with Lung Functions in Healthy Nonsmokers, Healthy Smokers, and Patients with COPD
title_full_unstemmed Reliability of Chest Wall Mobility and Its Correlation with Lung Functions in Healthy Nonsmokers, Healthy Smokers, and Patients with COPD
title_short Reliability of Chest Wall Mobility and Its Correlation with Lung Functions in Healthy Nonsmokers, Healthy Smokers, and Patients with COPD
title_sort reliability of chest wall mobility and its correlation with lung functions in healthy nonsmokers, healthy smokers, and patients with copd
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6410441/
https://www.ncbi.nlm.nih.gov/pubmed/30931074
http://dx.doi.org/10.1155/2019/5175949
work_keys_str_mv AT reddyravis reliabilityofchestwallmobilityanditscorrelationwithlungfunctionsinhealthynonsmokershealthysmokersandpatientswithcopd
AT alahmarikhalida reliabilityofchestwallmobilityanditscorrelationwithlungfunctionsinhealthynonsmokershealthysmokersandpatientswithcopd
AT silvianpauls reliabilityofchestwallmobilityanditscorrelationwithlungfunctionsinhealthynonsmokershealthysmokersandpatientswithcopd
AT ahmadirshada reliabilityofchestwallmobilityanditscorrelationwithlungfunctionsinhealthynonsmokershealthysmokersandpatientswithcopd
AT kakarparthivenkatanagaraj reliabilityofchestwallmobilityanditscorrelationwithlungfunctionsinhealthynonsmokershealthysmokersandpatientswithcopd
AT rengaramanujamkanagaraj reliabilityofchestwallmobilityanditscorrelationwithlungfunctionsinhealthynonsmokershealthysmokersandpatientswithcopd