Cargando…

External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques

BACKGROUND: The aim of the study was to evaluate and compare four different external beam radiotherapy techniques of accelerated partial breast irradiation (APBI) considering target coverage, dose to organs at risk and overall plan quality. The investigated techniques were three dimensional conforma...

Descripción completa

Detalles Bibliográficos
Autores principales: Stelczer, Gábor, Major, Tibor, Mészáros, Norbert, Polgár, Csaba, Pesznyák, Csilla
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sciendo 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6411019/
https://www.ncbi.nlm.nih.gov/pubmed/30661060
http://dx.doi.org/10.2478/raon-2019-0001
_version_ 1783402332847865856
author Stelczer, Gábor
Major, Tibor
Mészáros, Norbert
Polgár, Csaba
Pesznyák, Csilla
author_facet Stelczer, Gábor
Major, Tibor
Mészáros, Norbert
Polgár, Csaba
Pesznyák, Csilla
author_sort Stelczer, Gábor
collection PubMed
description BACKGROUND: The aim of the study was to evaluate and compare four different external beam radiotherapy techniques of accelerated partial breast irradiation (APBI) considering target coverage, dose to organs at risk and overall plan quality. The investigated techniques were three dimensional conformal radiotherapy (3D-CRT), “step and shoot” (SS) and “sliding window” (SW) intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (RA). PATIENTS AND METHODS: CT scans of 40 APBI patients were selected for the study. The planning objectives were set up according to the international recommendations. Homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. RESULTS: There were no significant differences in the coverage of the target volume between the techniques. The homogeneity indices of 3D-CRT, SS, SW and RA plans were 0.068, 0.074, 0.058 and 0.081, respectively. The conformation numbers were 0.60, 0.80, 0.82 and 0.89, respectively. The V(50%) values of the ipsilateral breast for 3D-CRT, SS, SW and RA were 47.5%, 40.2%, 39.9% and 31.6%, respectively. The average V(10%) and V(40%) values of ipsilateral lung were 13.1%, 28.1%, 28%, 36% and 2.6%, 1.9%, 1.9%, 3%, respectively. The 3D-CRT technique provided the best heart protection, especially in the low dose region. All contralateral organs received low doses. The SW technique achieved the best plan quality index (PQI). CONCLUSIONS: Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all aspects, we recommend the SW IMRT technique for APBI.
format Online
Article
Text
id pubmed-6411019
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Sciendo
record_format MEDLINE/PubMed
spelling pubmed-64110192019-03-13 External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques Stelczer, Gábor Major, Tibor Mészáros, Norbert Polgár, Csaba Pesznyák, Csilla Radiol Oncol Research Article BACKGROUND: The aim of the study was to evaluate and compare four different external beam radiotherapy techniques of accelerated partial breast irradiation (APBI) considering target coverage, dose to organs at risk and overall plan quality. The investigated techniques were three dimensional conformal radiotherapy (3D-CRT), “step and shoot” (SS) and “sliding window” (SW) intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (RA). PATIENTS AND METHODS: CT scans of 40 APBI patients were selected for the study. The planning objectives were set up according to the international recommendations. Homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. RESULTS: There were no significant differences in the coverage of the target volume between the techniques. The homogeneity indices of 3D-CRT, SS, SW and RA plans were 0.068, 0.074, 0.058 and 0.081, respectively. The conformation numbers were 0.60, 0.80, 0.82 and 0.89, respectively. The V(50%) values of the ipsilateral breast for 3D-CRT, SS, SW and RA were 47.5%, 40.2%, 39.9% and 31.6%, respectively. The average V(10%) and V(40%) values of ipsilateral lung were 13.1%, 28.1%, 28%, 36% and 2.6%, 1.9%, 1.9%, 3%, respectively. The 3D-CRT technique provided the best heart protection, especially in the low dose region. All contralateral organs received low doses. The SW technique achieved the best plan quality index (PQI). CONCLUSIONS: Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all aspects, we recommend the SW IMRT technique for APBI. Sciendo 2019-01-19 /pmc/articles/PMC6411019/ /pubmed/30661060 http://dx.doi.org/10.2478/raon-2019-0001 Text en © 2019 Gábor Stelczer, Tibor Major, Norbert Mészáros, Csaba Polgár, Csilla Pesznyák, published by Sciendo http://creativecommons.org/licenses/by-nc-nd/3.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
spellingShingle Research Article
Stelczer, Gábor
Major, Tibor
Mészáros, Norbert
Polgár, Csaba
Pesznyák, Csilla
External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques
title External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques
title_full External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques
title_fullStr External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques
title_full_unstemmed External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques
title_short External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques
title_sort external beam accelerated partial breast irradiation: dosimetric assessment of conformal and three different intensity modulated techniques
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6411019/
https://www.ncbi.nlm.nih.gov/pubmed/30661060
http://dx.doi.org/10.2478/raon-2019-0001
work_keys_str_mv AT stelczergabor externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques
AT majortibor externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques
AT meszarosnorbert externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques
AT polgarcsaba externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques
AT pesznyakcsilla externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques