Cargando…
External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques
BACKGROUND: The aim of the study was to evaluate and compare four different external beam radiotherapy techniques of accelerated partial breast irradiation (APBI) considering target coverage, dose to organs at risk and overall plan quality. The investigated techniques were three dimensional conforma...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sciendo
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6411019/ https://www.ncbi.nlm.nih.gov/pubmed/30661060 http://dx.doi.org/10.2478/raon-2019-0001 |
_version_ | 1783402332847865856 |
---|---|
author | Stelczer, Gábor Major, Tibor Mészáros, Norbert Polgár, Csaba Pesznyák, Csilla |
author_facet | Stelczer, Gábor Major, Tibor Mészáros, Norbert Polgár, Csaba Pesznyák, Csilla |
author_sort | Stelczer, Gábor |
collection | PubMed |
description | BACKGROUND: The aim of the study was to evaluate and compare four different external beam radiotherapy techniques of accelerated partial breast irradiation (APBI) considering target coverage, dose to organs at risk and overall plan quality. The investigated techniques were three dimensional conformal radiotherapy (3D-CRT), “step and shoot” (SS) and “sliding window” (SW) intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (RA). PATIENTS AND METHODS: CT scans of 40 APBI patients were selected for the study. The planning objectives were set up according to the international recommendations. Homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. RESULTS: There were no significant differences in the coverage of the target volume between the techniques. The homogeneity indices of 3D-CRT, SS, SW and RA plans were 0.068, 0.074, 0.058 and 0.081, respectively. The conformation numbers were 0.60, 0.80, 0.82 and 0.89, respectively. The V(50%) values of the ipsilateral breast for 3D-CRT, SS, SW and RA were 47.5%, 40.2%, 39.9% and 31.6%, respectively. The average V(10%) and V(40%) values of ipsilateral lung were 13.1%, 28.1%, 28%, 36% and 2.6%, 1.9%, 1.9%, 3%, respectively. The 3D-CRT technique provided the best heart protection, especially in the low dose region. All contralateral organs received low doses. The SW technique achieved the best plan quality index (PQI). CONCLUSIONS: Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all aspects, we recommend the SW IMRT technique for APBI. |
format | Online Article Text |
id | pubmed-6411019 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Sciendo |
record_format | MEDLINE/PubMed |
spelling | pubmed-64110192019-03-13 External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques Stelczer, Gábor Major, Tibor Mészáros, Norbert Polgár, Csaba Pesznyák, Csilla Radiol Oncol Research Article BACKGROUND: The aim of the study was to evaluate and compare four different external beam radiotherapy techniques of accelerated partial breast irradiation (APBI) considering target coverage, dose to organs at risk and overall plan quality. The investigated techniques were three dimensional conformal radiotherapy (3D-CRT), “step and shoot” (SS) and “sliding window” (SW) intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (RA). PATIENTS AND METHODS: CT scans of 40 APBI patients were selected for the study. The planning objectives were set up according to the international recommendations. Homogeneity, conformity and plan quality indices were calculated from volumetric and dosimetric parameters of target volumes and organs at risk. The total monitor units and feasibility were also investigated. RESULTS: There were no significant differences in the coverage of the target volume between the techniques. The homogeneity indices of 3D-CRT, SS, SW and RA plans were 0.068, 0.074, 0.058 and 0.081, respectively. The conformation numbers were 0.60, 0.80, 0.82 and 0.89, respectively. The V(50%) values of the ipsilateral breast for 3D-CRT, SS, SW and RA were 47.5%, 40.2%, 39.9% and 31.6%, respectively. The average V(10%) and V(40%) values of ipsilateral lung were 13.1%, 28.1%, 28%, 36% and 2.6%, 1.9%, 1.9%, 3%, respectively. The 3D-CRT technique provided the best heart protection, especially in the low dose region. All contralateral organs received low doses. The SW technique achieved the best plan quality index (PQI). CONCLUSIONS: Good target volume coverage and tolerable dose to the organs at risk are achievable with all four techniques. Taking into account all aspects, we recommend the SW IMRT technique for APBI. Sciendo 2019-01-19 /pmc/articles/PMC6411019/ /pubmed/30661060 http://dx.doi.org/10.2478/raon-2019-0001 Text en © 2019 Gábor Stelczer, Tibor Major, Norbert Mészáros, Csaba Polgár, Csilla Pesznyák, published by Sciendo http://creativecommons.org/licenses/by-nc-nd/3.0 This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License. |
spellingShingle | Research Article Stelczer, Gábor Major, Tibor Mészáros, Norbert Polgár, Csaba Pesznyák, Csilla External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques |
title | External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques |
title_full | External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques |
title_fullStr | External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques |
title_full_unstemmed | External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques |
title_short | External Beam Accelerated Partial Breast Irradiation: Dosimetric Assessment of Conformal and Three Different Intensity Modulated Techniques |
title_sort | external beam accelerated partial breast irradiation: dosimetric assessment of conformal and three different intensity modulated techniques |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6411019/ https://www.ncbi.nlm.nih.gov/pubmed/30661060 http://dx.doi.org/10.2478/raon-2019-0001 |
work_keys_str_mv | AT stelczergabor externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques AT majortibor externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques AT meszarosnorbert externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques AT polgarcsaba externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques AT pesznyakcsilla externalbeamacceleratedpartialbreastirradiationdosimetricassessmentofconformalandthreedifferentintensitymodulatedtechniques |