X-ray optics for advanced ultrafast pump–probe X-ray experiments at SACLA
X-ray optics were implemented for advanced ultrafast X-ray experiments with different techniques at the hard X-ray beamline BL3 of SPring-8 Ångstrom Compact free-electron LAser. A double channel-cut crystal monochromator (DCCM) and compound refractive lenses (CRLs) were installed to tailor the beam...
Autores principales: | Katayama, Tetsuo, Hirano, Takashi, Morioka, Yuki, Sano, Yasuhisa, Osaka, Taito, Owada, Shigeki, Togashi, Tadashi, Yabashi, Makina |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412179/ https://www.ncbi.nlm.nih.gov/pubmed/30855240 http://dx.doi.org/10.1107/S1600577518018362 |
Ejemplares similares
-
Arrival timing diagnostics at a soft X-ray free-electron laser beamline of SACLA BL1
por: Owada, Shigeki, et al.
Publicado: (2019) -
A versatile experimental system for tracking ultrafast chemical reactions with X-ray free-electron lasers
por: Katayama, Tetsuo, et al.
Publicado: (2019) -
Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms
por: Osaka, Taito, et al.
Publicado: (2017) -
Performance of a hard X-ray split-and-delay optical system with a wavefront division
por: Hirano, Takashi, et al.
Publicado: (2018) -
Polarization control with an X-ray phase retarder for high-time-resolution pump–probe experiments at SACLA
por: Kubota, Y., et al.
Publicado: (2019)