Cargando…

All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant

All-solid-state potentiometric sensors were prepared by using polyaniline (PANI) as the solid contact material. A film of PANI (thickness approximately being 0.25 µm) was deposited on a solid substrate (carbon screen printed platform). The PANI layer was subsequently coated with an ion-selective mem...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdalla, Nashwa S., Youssef, Maha A., Algarni, H., Awwad, Nasser S., Kamel, Ayman H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412243/
https://www.ncbi.nlm.nih.gov/pubmed/30781449
http://dx.doi.org/10.3390/molecules24040712
_version_ 1783402559998787584
author Abdalla, Nashwa S.
Youssef, Maha A.
Algarni, H.
Awwad, Nasser S.
Kamel, Ayman H.
author_facet Abdalla, Nashwa S.
Youssef, Maha A.
Algarni, H.
Awwad, Nasser S.
Kamel, Ayman H.
author_sort Abdalla, Nashwa S.
collection PubMed
description All-solid-state potentiometric sensors were prepared by using polyaniline (PANI) as the solid contact material. A film of PANI (thickness approximately being 0.25 µm) was deposited on a solid substrate (carbon screen printed platform). The PANI layer was subsequently coated with an ion-selective membrane (ISM) containing uniform-sized molecularly imprinted nanoparticles to produce a solid-contact ion-selective electrode (SC/ISE) for bispyribac herbicide (sensor I). In addition, aliquat 336 was also used as an ion exchanger in plasticized PVC membrane (sensor II). The proposed sensors revealed a remarkably improved sensitivity towards bispyribac ions with anionic slopes of −47.8 ± 1.1 (r(2) = 0.9995) and −44.4 ± 1.4 (r(2) = 0.9997) mV/decade over a linear range 1.0 × 10(−2)–8.6 × 10(−6) M, 1.0 × 10(−2)–9.0 × 10(−6) M and detection limits of 1.33 and 1.81 µg/mL for sensors I and II, respectively.Selectivity of both sensors is significantly high for different common pesticides and inorganic anions. The potential stability of the SC/ISEs was studied using chronopotentiometry. Electrochemical impedance spectrometry was used to understand the charge-transfer mechanisms of the different types of ion-selective electrodes studied. The impedance response of the electrodes was modelled by using equivalent electrical circuits. The sensors were used for a direct measurement of the bispyribac content in commercial herbicide formulations and soil samples collected from agricultural lands planted with rice and sprayed with bispyribac herbicide. The results agree fairly well with data obtained using HPLC method.
format Online
Article
Text
id pubmed-6412243
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64122432019-04-09 All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant Abdalla, Nashwa S. Youssef, Maha A. Algarni, H. Awwad, Nasser S. Kamel, Ayman H. Molecules Article All-solid-state potentiometric sensors were prepared by using polyaniline (PANI) as the solid contact material. A film of PANI (thickness approximately being 0.25 µm) was deposited on a solid substrate (carbon screen printed platform). The PANI layer was subsequently coated with an ion-selective membrane (ISM) containing uniform-sized molecularly imprinted nanoparticles to produce a solid-contact ion-selective electrode (SC/ISE) for bispyribac herbicide (sensor I). In addition, aliquat 336 was also used as an ion exchanger in plasticized PVC membrane (sensor II). The proposed sensors revealed a remarkably improved sensitivity towards bispyribac ions with anionic slopes of −47.8 ± 1.1 (r(2) = 0.9995) and −44.4 ± 1.4 (r(2) = 0.9997) mV/decade over a linear range 1.0 × 10(−2)–8.6 × 10(−6) M, 1.0 × 10(−2)–9.0 × 10(−6) M and detection limits of 1.33 and 1.81 µg/mL for sensors I and II, respectively.Selectivity of both sensors is significantly high for different common pesticides and inorganic anions. The potential stability of the SC/ISEs was studied using chronopotentiometry. Electrochemical impedance spectrometry was used to understand the charge-transfer mechanisms of the different types of ion-selective electrodes studied. The impedance response of the electrodes was modelled by using equivalent electrical circuits. The sensors were used for a direct measurement of the bispyribac content in commercial herbicide formulations and soil samples collected from agricultural lands planted with rice and sprayed with bispyribac herbicide. The results agree fairly well with data obtained using HPLC method. MDPI 2019-02-16 /pmc/articles/PMC6412243/ /pubmed/30781449 http://dx.doi.org/10.3390/molecules24040712 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Abdalla, Nashwa S.
Youssef, Maha A.
Algarni, H.
Awwad, Nasser S.
Kamel, Ayman H.
All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant
title All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant
title_full All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant
title_fullStr All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant
title_full_unstemmed All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant
title_short All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant
title_sort all solid-state poly (vinyl chloride) membrane potentiometric sensor integrated with nano-beads imprinted polymers for sensitive and rapid detection of bispyribac herbicide as organic pollutant
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412243/
https://www.ncbi.nlm.nih.gov/pubmed/30781449
http://dx.doi.org/10.3390/molecules24040712
work_keys_str_mv AT abdallanashwas allsolidstatepolyvinylchloridemembranepotentiometricsensorintegratedwithnanobeadsimprintedpolymersforsensitiveandrapiddetectionofbispyribacherbicideasorganicpollutant
AT youssefmahaa allsolidstatepolyvinylchloridemembranepotentiometricsensorintegratedwithnanobeadsimprintedpolymersforsensitiveandrapiddetectionofbispyribacherbicideasorganicpollutant
AT algarnih allsolidstatepolyvinylchloridemembranepotentiometricsensorintegratedwithnanobeadsimprintedpolymersforsensitiveandrapiddetectionofbispyribacherbicideasorganicpollutant
AT awwadnassers allsolidstatepolyvinylchloridemembranepotentiometricsensorintegratedwithnanobeadsimprintedpolymersforsensitiveandrapiddetectionofbispyribacherbicideasorganicpollutant
AT kamelaymanh allsolidstatepolyvinylchloridemembranepotentiometricsensorintegratedwithnanobeadsimprintedpolymersforsensitiveandrapiddetectionofbispyribacherbicideasorganicpollutant