Cargando…

Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism

The principle of a zero-compliance mechanism was used to develop a three-dimensional force measurement instrument. In each axis, the point of force is suspended by a zero-compliance mechanism. A vertical axis force estimation operation imitates the structure of a double series magnetic suspension sy...

Descripción completa

Detalles Bibliográficos
Autores principales: Nahiyan, Md Helal An, Mizuno, Takeshi, Takasaki, Masaya, Ishino, Yuji, Hara, Masayuki, Yamaguchi, Daisuke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412571/
https://www.ncbi.nlm.nih.gov/pubmed/30781419
http://dx.doi.org/10.3390/s19040799
_version_ 1783402636374966272
author Nahiyan, Md Helal An
Mizuno, Takeshi
Takasaki, Masaya
Ishino, Yuji
Hara, Masayuki
Yamaguchi, Daisuke
author_facet Nahiyan, Md Helal An
Mizuno, Takeshi
Takasaki, Masaya
Ishino, Yuji
Hara, Masayuki
Yamaguchi, Daisuke
author_sort Nahiyan, Md Helal An
collection PubMed
description The principle of a zero-compliance mechanism was used to develop a three-dimensional force measurement instrument. In each axis, the point of force is suspended by a zero-compliance mechanism. A vertical axis force estimation operation imitates the structure of a double series magnetic suspension system. An electromagnet directly controls the movement of the first suspended object (floator), which is denoted as a detection point, and indirectly controls the motion of the second floator, which is denoted as a point of force. Indirect control of the point of force is executed by the attractive force of a permanent magnet that is fixed to the bottom part of the detection point. To achieve zero-compliance, a Proportional-Integral-Derivative (PID) control is applied to the point of force, and to make the system stable, a Proportional-Derivative (PD) control is also applied to the detection point. In such suspension conditions, when force is exerted on the point of force, the displacement of the second floator is regulated to maintain its primary position while the detection point displaces in proportion to the applied force. Thus, a zero-compliance condition is maintained at the point of force, and the external force is measured from the linear displacement of the detection point. To restrict the motions of the detection point and the point of force in translation only, they are supported with leaf springs. This paper presents the modeling of the vertical direction force measurement operation of the developed three-axis force estimation instrument, and the theoretical analyses were validated by experiments of force measurement in both the millinewton and micronewton ranges.
format Online
Article
Text
id pubmed-6412571
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64125712019-04-03 Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism Nahiyan, Md Helal An Mizuno, Takeshi Takasaki, Masaya Ishino, Yuji Hara, Masayuki Yamaguchi, Daisuke Sensors (Basel) Article The principle of a zero-compliance mechanism was used to develop a three-dimensional force measurement instrument. In each axis, the point of force is suspended by a zero-compliance mechanism. A vertical axis force estimation operation imitates the structure of a double series magnetic suspension system. An electromagnet directly controls the movement of the first suspended object (floator), which is denoted as a detection point, and indirectly controls the motion of the second floator, which is denoted as a point of force. Indirect control of the point of force is executed by the attractive force of a permanent magnet that is fixed to the bottom part of the detection point. To achieve zero-compliance, a Proportional-Integral-Derivative (PID) control is applied to the point of force, and to make the system stable, a Proportional-Derivative (PD) control is also applied to the detection point. In such suspension conditions, when force is exerted on the point of force, the displacement of the second floator is regulated to maintain its primary position while the detection point displaces in proportion to the applied force. Thus, a zero-compliance condition is maintained at the point of force, and the external force is measured from the linear displacement of the detection point. To restrict the motions of the detection point and the point of force in translation only, they are supported with leaf springs. This paper presents the modeling of the vertical direction force measurement operation of the developed three-axis force estimation instrument, and the theoretical analyses were validated by experiments of force measurement in both the millinewton and micronewton ranges. MDPI 2019-02-15 /pmc/articles/PMC6412571/ /pubmed/30781419 http://dx.doi.org/10.3390/s19040799 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nahiyan, Md Helal An
Mizuno, Takeshi
Takasaki, Masaya
Ishino, Yuji
Hara, Masayuki
Yamaguchi, Daisuke
Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism
title Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism
title_full Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism
title_fullStr Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism
title_full_unstemmed Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism
title_short Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism
title_sort modeling and validation of vertical direction force estimation with a three-dimensional force measurement instrument based on a zero-compliance mechanism
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412571/
https://www.ncbi.nlm.nih.gov/pubmed/30781419
http://dx.doi.org/10.3390/s19040799
work_keys_str_mv AT nahiyanmdhelalan modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism
AT mizunotakeshi modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism
AT takasakimasaya modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism
AT ishinoyuji modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism
AT haramasayuki modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism
AT yamaguchidaisuke modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism