Cargando…
Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism
The principle of a zero-compliance mechanism was used to develop a three-dimensional force measurement instrument. In each axis, the point of force is suspended by a zero-compliance mechanism. A vertical axis force estimation operation imitates the structure of a double series magnetic suspension sy...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412571/ https://www.ncbi.nlm.nih.gov/pubmed/30781419 http://dx.doi.org/10.3390/s19040799 |
_version_ | 1783402636374966272 |
---|---|
author | Nahiyan, Md Helal An Mizuno, Takeshi Takasaki, Masaya Ishino, Yuji Hara, Masayuki Yamaguchi, Daisuke |
author_facet | Nahiyan, Md Helal An Mizuno, Takeshi Takasaki, Masaya Ishino, Yuji Hara, Masayuki Yamaguchi, Daisuke |
author_sort | Nahiyan, Md Helal An |
collection | PubMed |
description | The principle of a zero-compliance mechanism was used to develop a three-dimensional force measurement instrument. In each axis, the point of force is suspended by a zero-compliance mechanism. A vertical axis force estimation operation imitates the structure of a double series magnetic suspension system. An electromagnet directly controls the movement of the first suspended object (floator), which is denoted as a detection point, and indirectly controls the motion of the second floator, which is denoted as a point of force. Indirect control of the point of force is executed by the attractive force of a permanent magnet that is fixed to the bottom part of the detection point. To achieve zero-compliance, a Proportional-Integral-Derivative (PID) control is applied to the point of force, and to make the system stable, a Proportional-Derivative (PD) control is also applied to the detection point. In such suspension conditions, when force is exerted on the point of force, the displacement of the second floator is regulated to maintain its primary position while the detection point displaces in proportion to the applied force. Thus, a zero-compliance condition is maintained at the point of force, and the external force is measured from the linear displacement of the detection point. To restrict the motions of the detection point and the point of force in translation only, they are supported with leaf springs. This paper presents the modeling of the vertical direction force measurement operation of the developed three-axis force estimation instrument, and the theoretical analyses were validated by experiments of force measurement in both the millinewton and micronewton ranges. |
format | Online Article Text |
id | pubmed-6412571 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64125712019-04-03 Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism Nahiyan, Md Helal An Mizuno, Takeshi Takasaki, Masaya Ishino, Yuji Hara, Masayuki Yamaguchi, Daisuke Sensors (Basel) Article The principle of a zero-compliance mechanism was used to develop a three-dimensional force measurement instrument. In each axis, the point of force is suspended by a zero-compliance mechanism. A vertical axis force estimation operation imitates the structure of a double series magnetic suspension system. An electromagnet directly controls the movement of the first suspended object (floator), which is denoted as a detection point, and indirectly controls the motion of the second floator, which is denoted as a point of force. Indirect control of the point of force is executed by the attractive force of a permanent magnet that is fixed to the bottom part of the detection point. To achieve zero-compliance, a Proportional-Integral-Derivative (PID) control is applied to the point of force, and to make the system stable, a Proportional-Derivative (PD) control is also applied to the detection point. In such suspension conditions, when force is exerted on the point of force, the displacement of the second floator is regulated to maintain its primary position while the detection point displaces in proportion to the applied force. Thus, a zero-compliance condition is maintained at the point of force, and the external force is measured from the linear displacement of the detection point. To restrict the motions of the detection point and the point of force in translation only, they are supported with leaf springs. This paper presents the modeling of the vertical direction force measurement operation of the developed three-axis force estimation instrument, and the theoretical analyses were validated by experiments of force measurement in both the millinewton and micronewton ranges. MDPI 2019-02-15 /pmc/articles/PMC6412571/ /pubmed/30781419 http://dx.doi.org/10.3390/s19040799 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Nahiyan, Md Helal An Mizuno, Takeshi Takasaki, Masaya Ishino, Yuji Hara, Masayuki Yamaguchi, Daisuke Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism |
title | Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism |
title_full | Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism |
title_fullStr | Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism |
title_full_unstemmed | Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism |
title_short | Modeling and Validation of Vertical Direction Force Estimation with a Three-Dimensional Force Measurement Instrument Based on a Zero-Compliance Mechanism |
title_sort | modeling and validation of vertical direction force estimation with a three-dimensional force measurement instrument based on a zero-compliance mechanism |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412571/ https://www.ncbi.nlm.nih.gov/pubmed/30781419 http://dx.doi.org/10.3390/s19040799 |
work_keys_str_mv | AT nahiyanmdhelalan modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism AT mizunotakeshi modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism AT takasakimasaya modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism AT ishinoyuji modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism AT haramasayuki modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism AT yamaguchidaisuke modelingandvalidationofverticaldirectionforceestimationwithathreedimensionalforcemeasurementinstrumentbasedonazerocompliancemechanism |