Cargando…

Ammonia Distribution Measurement on a Hot Gas Test Bench Applying Tomographical Optical Methods †

Measuring the distribution of gas concentration is a very common problem in a variety of technological fields. Depending on the detectability of the gas, as well as the technological progress of the sector, different methods are used. In this paper, we present a device and methods to detect the ammo...

Descripción completa

Detalles Bibliográficos
Autores principales: Fischbacher, Bernhard, Lechner, Bernhard, Brandstätter, Bernhard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412577/
https://www.ncbi.nlm.nih.gov/pubmed/30795519
http://dx.doi.org/10.3390/s19040896
_version_ 1783402637769572352
author Fischbacher, Bernhard
Lechner, Bernhard
Brandstätter, Bernhard
author_facet Fischbacher, Bernhard
Lechner, Bernhard
Brandstätter, Bernhard
author_sort Fischbacher, Bernhard
collection PubMed
description Measuring the distribution of gas concentration is a very common problem in a variety of technological fields. Depending on the detectability of the gas, as well as the technological progress of the sector, different methods are used. In this paper, we present a device and methods to detect the ammonia concentration distribution in the exhaust system of diesel engines in order to increase the performance of the exhaust aftertreatment system. The device has been designed for usage on a hot gas test bench simulating exhaust gas conditions. It consists of multiple optical beams measuring ammonia line concentrations by applying nondispersive absorption spectroscopy in the deep ultraviolet region. The detectors consist of photodiodes allowing high sampling rates up to 3 kHz while providing a high signal-to-noise ratio. A detection limit of only 1 ppm has been achieved despite the short path length of only eight centimeters. The obtained line concentrations form an inverse problem. The methodology of the tomographic techniques is described in detail in order to best solve the inverse problem and obtain the ammonia concentration distribution images for each time step.
format Online
Article
Text
id pubmed-6412577
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64125772019-04-03 Ammonia Distribution Measurement on a Hot Gas Test Bench Applying Tomographical Optical Methods † Fischbacher, Bernhard Lechner, Bernhard Brandstätter, Bernhard Sensors (Basel) Article Measuring the distribution of gas concentration is a very common problem in a variety of technological fields. Depending on the detectability of the gas, as well as the technological progress of the sector, different methods are used. In this paper, we present a device and methods to detect the ammonia concentration distribution in the exhaust system of diesel engines in order to increase the performance of the exhaust aftertreatment system. The device has been designed for usage on a hot gas test bench simulating exhaust gas conditions. It consists of multiple optical beams measuring ammonia line concentrations by applying nondispersive absorption spectroscopy in the deep ultraviolet region. The detectors consist of photodiodes allowing high sampling rates up to 3 kHz while providing a high signal-to-noise ratio. A detection limit of only 1 ppm has been achieved despite the short path length of only eight centimeters. The obtained line concentrations form an inverse problem. The methodology of the tomographic techniques is described in detail in order to best solve the inverse problem and obtain the ammonia concentration distribution images for each time step. MDPI 2019-02-21 /pmc/articles/PMC6412577/ /pubmed/30795519 http://dx.doi.org/10.3390/s19040896 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fischbacher, Bernhard
Lechner, Bernhard
Brandstätter, Bernhard
Ammonia Distribution Measurement on a Hot Gas Test Bench Applying Tomographical Optical Methods †
title Ammonia Distribution Measurement on a Hot Gas Test Bench Applying Tomographical Optical Methods †
title_full Ammonia Distribution Measurement on a Hot Gas Test Bench Applying Tomographical Optical Methods †
title_fullStr Ammonia Distribution Measurement on a Hot Gas Test Bench Applying Tomographical Optical Methods †
title_full_unstemmed Ammonia Distribution Measurement on a Hot Gas Test Bench Applying Tomographical Optical Methods †
title_short Ammonia Distribution Measurement on a Hot Gas Test Bench Applying Tomographical Optical Methods †
title_sort ammonia distribution measurement on a hot gas test bench applying tomographical optical methods †
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412577/
https://www.ncbi.nlm.nih.gov/pubmed/30795519
http://dx.doi.org/10.3390/s19040896
work_keys_str_mv AT fischbacherbernhard ammoniadistributionmeasurementonahotgastestbenchapplyingtomographicalopticalmethods
AT lechnerbernhard ammoniadistributionmeasurementonahotgastestbenchapplyingtomographicalopticalmethods
AT brandstatterbernhard ammoniadistributionmeasurementonahotgastestbenchapplyingtomographicalopticalmethods