Cargando…

Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection

In this paper, a self-out-readable, miniaturized cantilever resonator for highly sensitive airborne nanoparticle (NP) detection is presented. The cantilever, which is operated in the fundamental in-plane resonance mode, is used as a microbalance with femtogram resolution. To maximize sensitivity and...

Descripción completa

Detalles Bibliográficos
Autores principales: Bertke, Maik, Xu, Jiushuai, Fahrbach, Michael, Setiono, Andi, Wasisto, Hutomo Suryo, Peiner, Erwin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412668/
https://www.ncbi.nlm.nih.gov/pubmed/30795547
http://dx.doi.org/10.3390/s19040901
_version_ 1783402659232874496
author Bertke, Maik
Xu, Jiushuai
Fahrbach, Michael
Setiono, Andi
Wasisto, Hutomo Suryo
Peiner, Erwin
author_facet Bertke, Maik
Xu, Jiushuai
Fahrbach, Michael
Setiono, Andi
Wasisto, Hutomo Suryo
Peiner, Erwin
author_sort Bertke, Maik
collection PubMed
description In this paper, a self-out-readable, miniaturized cantilever resonator for highly sensitive airborne nanoparticle (NP) detection is presented. The cantilever, which is operated in the fundamental in-plane resonance mode, is used as a microbalance with femtogram resolution. To maximize sensitivity and read-out signal amplitude of the piezo-resistive Wheatstone half bridge, the geometric parameters of the sensor design are optimized by finite element modelling (FEM). The electrical read-out of the cantilever movement is realized by piezo-resistive struts at the sides of the cantilever resonator that enable real-time tracking using a phase-locked loop (PLL) circuit. Cantilevers with minimum resonator mass of 1.72 ng and resonance frequency of ~440 kHz were fabricated, providing a theoretical sensitivity of 7.8 fg/Hz. In addition, for electrostatic NP collection, the cantilever has a negative-biased electrode located at its free end. Moreover, the counter-electrode surrounding the cantilever and a µ-channel, guiding the particle-laden air flow towards the cantilever, are integrated with the sensor chip. µ-channels and varying sampling voltages will also be used to accomplish particle separation for size-selective NP detection. To sum up, the presented airborne NP sensor is expected to demonstrate significant improvements in the field of handheld, micro-/nanoelectromechanical systems (M/NEMS)-based NP monitoring devices.
format Online
Article
Text
id pubmed-6412668
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64126682019-04-03 Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection Bertke, Maik Xu, Jiushuai Fahrbach, Michael Setiono, Andi Wasisto, Hutomo Suryo Peiner, Erwin Sensors (Basel) Article In this paper, a self-out-readable, miniaturized cantilever resonator for highly sensitive airborne nanoparticle (NP) detection is presented. The cantilever, which is operated in the fundamental in-plane resonance mode, is used as a microbalance with femtogram resolution. To maximize sensitivity and read-out signal amplitude of the piezo-resistive Wheatstone half bridge, the geometric parameters of the sensor design are optimized by finite element modelling (FEM). The electrical read-out of the cantilever movement is realized by piezo-resistive struts at the sides of the cantilever resonator that enable real-time tracking using a phase-locked loop (PLL) circuit. Cantilevers with minimum resonator mass of 1.72 ng and resonance frequency of ~440 kHz were fabricated, providing a theoretical sensitivity of 7.8 fg/Hz. In addition, for electrostatic NP collection, the cantilever has a negative-biased electrode located at its free end. Moreover, the counter-electrode surrounding the cantilever and a µ-channel, guiding the particle-laden air flow towards the cantilever, are integrated with the sensor chip. µ-channels and varying sampling voltages will also be used to accomplish particle separation for size-selective NP detection. To sum up, the presented airborne NP sensor is expected to demonstrate significant improvements in the field of handheld, micro-/nanoelectromechanical systems (M/NEMS)-based NP monitoring devices. MDPI 2019-02-21 /pmc/articles/PMC6412668/ /pubmed/30795547 http://dx.doi.org/10.3390/s19040901 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bertke, Maik
Xu, Jiushuai
Fahrbach, Michael
Setiono, Andi
Wasisto, Hutomo Suryo
Peiner, Erwin
Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection
title Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection
title_full Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection
title_fullStr Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection
title_full_unstemmed Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection
title_short Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection
title_sort strategy toward miniaturized, self-out-readable resonant cantilever and integrated electrostatic microchannel separator for highly sensitive airborne nanoparticle detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412668/
https://www.ncbi.nlm.nih.gov/pubmed/30795547
http://dx.doi.org/10.3390/s19040901
work_keys_str_mv AT bertkemaik strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection
AT xujiushuai strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection
AT fahrbachmichael strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection
AT setionoandi strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection
AT wasistohutomosuryo strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection
AT peinererwin strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection