Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection
In this paper, a self-out-readable, miniaturized cantilever resonator for highly sensitive airborne nanoparticle (NP) detection is presented. The cantilever, which is operated in the fundamental in-plane resonance mode, is used as a microbalance with femtogram resolution. To maximize sensitivity and...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412668/ https://www.ncbi.nlm.nih.gov/pubmed/30795547 http://dx.doi.org/10.3390/s19040901 |
_version_ | 1783402659232874496 |
---|---|
author | Bertke, Maik Xu, Jiushuai Fahrbach, Michael Setiono, Andi Wasisto, Hutomo Suryo Peiner, Erwin |
author_facet | Bertke, Maik Xu, Jiushuai Fahrbach, Michael Setiono, Andi Wasisto, Hutomo Suryo Peiner, Erwin |
author_sort | Bertke, Maik |
collection | PubMed |
description | In this paper, a self-out-readable, miniaturized cantilever resonator for highly sensitive airborne nanoparticle (NP) detection is presented. The cantilever, which is operated in the fundamental in-plane resonance mode, is used as a microbalance with femtogram resolution. To maximize sensitivity and read-out signal amplitude of the piezo-resistive Wheatstone half bridge, the geometric parameters of the sensor design are optimized by finite element modelling (FEM). The electrical read-out of the cantilever movement is realized by piezo-resistive struts at the sides of the cantilever resonator that enable real-time tracking using a phase-locked loop (PLL) circuit. Cantilevers with minimum resonator mass of 1.72 ng and resonance frequency of ~440 kHz were fabricated, providing a theoretical sensitivity of 7.8 fg/Hz. In addition, for electrostatic NP collection, the cantilever has a negative-biased electrode located at its free end. Moreover, the counter-electrode surrounding the cantilever and a µ-channel, guiding the particle-laden air flow towards the cantilever, are integrated with the sensor chip. µ-channels and varying sampling voltages will also be used to accomplish particle separation for size-selective NP detection. To sum up, the presented airborne NP sensor is expected to demonstrate significant improvements in the field of handheld, micro-/nanoelectromechanical systems (M/NEMS)-based NP monitoring devices. |
format | Online Article Text |
id | pubmed-6412668 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64126682019-04-03 Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection Bertke, Maik Xu, Jiushuai Fahrbach, Michael Setiono, Andi Wasisto, Hutomo Suryo Peiner, Erwin Sensors (Basel) Article In this paper, a self-out-readable, miniaturized cantilever resonator for highly sensitive airborne nanoparticle (NP) detection is presented. The cantilever, which is operated in the fundamental in-plane resonance mode, is used as a microbalance with femtogram resolution. To maximize sensitivity and read-out signal amplitude of the piezo-resistive Wheatstone half bridge, the geometric parameters of the sensor design are optimized by finite element modelling (FEM). The electrical read-out of the cantilever movement is realized by piezo-resistive struts at the sides of the cantilever resonator that enable real-time tracking using a phase-locked loop (PLL) circuit. Cantilevers with minimum resonator mass of 1.72 ng and resonance frequency of ~440 kHz were fabricated, providing a theoretical sensitivity of 7.8 fg/Hz. In addition, for electrostatic NP collection, the cantilever has a negative-biased electrode located at its free end. Moreover, the counter-electrode surrounding the cantilever and a µ-channel, guiding the particle-laden air flow towards the cantilever, are integrated with the sensor chip. µ-channels and varying sampling voltages will also be used to accomplish particle separation for size-selective NP detection. To sum up, the presented airborne NP sensor is expected to demonstrate significant improvements in the field of handheld, micro-/nanoelectromechanical systems (M/NEMS)-based NP monitoring devices. MDPI 2019-02-21 /pmc/articles/PMC6412668/ /pubmed/30795547 http://dx.doi.org/10.3390/s19040901 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bertke, Maik Xu, Jiushuai Fahrbach, Michael Setiono, Andi Wasisto, Hutomo Suryo Peiner, Erwin Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection |
title | Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection |
title_full | Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection |
title_fullStr | Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection |
title_full_unstemmed | Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection |
title_short | Strategy toward Miniaturized, Self-out-Readable Resonant Cantilever and Integrated Electrostatic Microchannel Separator for Highly Sensitive Airborne Nanoparticle Detection |
title_sort | strategy toward miniaturized, self-out-readable resonant cantilever and integrated electrostatic microchannel separator for highly sensitive airborne nanoparticle detection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412668/ https://www.ncbi.nlm.nih.gov/pubmed/30795547 http://dx.doi.org/10.3390/s19040901 |
work_keys_str_mv | AT bertkemaik strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection AT xujiushuai strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection AT fahrbachmichael strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection AT setionoandi strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection AT wasistohutomosuryo strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection AT peinererwin strategytowardminiaturizedselfoutreadableresonantcantileverandintegratedelectrostaticmicrochannelseparatorforhighlysensitiveairbornenanoparticledetection |