Cargando…
Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples
The pillared-layer Zn-triazolate metal-organic framework (CIM-81) was synthesized, characterized, and used for the first time as a sorbent in a dispersive micro-solid phase extraction method. The method involves the determination of a variety of personal care products in wastewaters, including four...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412874/ https://www.ncbi.nlm.nih.gov/pubmed/30769919 http://dx.doi.org/10.3390/molecules24040690 |
_version_ | 1783402706983976960 |
---|---|
author | González-Hernández, Providencia Lago, Ana B. Pasán, Jorge Ruiz-Pérez, Catalina Ayala, Juan H. Afonso, Ana M. Pino, Verónica |
author_facet | González-Hernández, Providencia Lago, Ana B. Pasán, Jorge Ruiz-Pérez, Catalina Ayala, Juan H. Afonso, Ana M. Pino, Verónica |
author_sort | González-Hernández, Providencia |
collection | PubMed |
description | The pillared-layer Zn-triazolate metal-organic framework (CIM-81) was synthesized, characterized, and used for the first time as a sorbent in a dispersive micro-solid phase extraction method. The method involves the determination of a variety of personal care products in wastewaters, including four preservatives, four UV-filters, and one disinfectant, in combination with ultra-high performance liquid chromatography and UV detection. The CIM-81 MOF, constructed with an interesting mixed-ligand synthetic strategy, demonstrated a better extraction performance than other widely used MOFs in D-µSPE such as UiO-66, HKUST-1, and MIL-53(Al). The optimization of the method included a screening design followed by a Doehlert design. Optimum conditions required 10 mg of CIM-81 MOF in 10 mL of the aqueous sample at a pH of 5, 1 min of agitation by vortex and 3 min of centrifugation in the extraction step; and 1.2 mL of methanol and 4 min of vortex in the desorption step, followed by filtration, evaporation and reconstitution with 100 µL of the initial chromatographic mobile phase. The entire D-µSPE-UHPLC-UV method presented limits of detection down to 0.5 ng·mL(−1); intra-day and inter-day precision values for the lowest concentration level (15 ng·mL(−1))-as a relative standard deviation (in %)-lower than 8.7 and 13%, respectively; average relative recovery values of 115%; and enrichment factors ranging from ~3.6 to ~34. The reuse of the CIM-81 material was assessed not only in terms of maintaining the analytical performance but also in terms of its crystalline stability. |
format | Online Article Text |
id | pubmed-6412874 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64128742019-04-09 Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples González-Hernández, Providencia Lago, Ana B. Pasán, Jorge Ruiz-Pérez, Catalina Ayala, Juan H. Afonso, Ana M. Pino, Verónica Molecules Article The pillared-layer Zn-triazolate metal-organic framework (CIM-81) was synthesized, characterized, and used for the first time as a sorbent in a dispersive micro-solid phase extraction method. The method involves the determination of a variety of personal care products in wastewaters, including four preservatives, four UV-filters, and one disinfectant, in combination with ultra-high performance liquid chromatography and UV detection. The CIM-81 MOF, constructed with an interesting mixed-ligand synthetic strategy, demonstrated a better extraction performance than other widely used MOFs in D-µSPE such as UiO-66, HKUST-1, and MIL-53(Al). The optimization of the method included a screening design followed by a Doehlert design. Optimum conditions required 10 mg of CIM-81 MOF in 10 mL of the aqueous sample at a pH of 5, 1 min of agitation by vortex and 3 min of centrifugation in the extraction step; and 1.2 mL of methanol and 4 min of vortex in the desorption step, followed by filtration, evaporation and reconstitution with 100 µL of the initial chromatographic mobile phase. The entire D-µSPE-UHPLC-UV method presented limits of detection down to 0.5 ng·mL(−1); intra-day and inter-day precision values for the lowest concentration level (15 ng·mL(−1))-as a relative standard deviation (in %)-lower than 8.7 and 13%, respectively; average relative recovery values of 115%; and enrichment factors ranging from ~3.6 to ~34. The reuse of the CIM-81 material was assessed not only in terms of maintaining the analytical performance but also in terms of its crystalline stability. MDPI 2019-02-15 /pmc/articles/PMC6412874/ /pubmed/30769919 http://dx.doi.org/10.3390/molecules24040690 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article González-Hernández, Providencia Lago, Ana B. Pasán, Jorge Ruiz-Pérez, Catalina Ayala, Juan H. Afonso, Ana M. Pino, Verónica Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples |
title | Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples |
title_full | Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples |
title_fullStr | Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples |
title_full_unstemmed | Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples |
title_short | Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples |
title_sort | application of a pillared-layer zn-triazolate metal-organic framework in the dispersive miniaturized solid-phase extraction of personal care products from wastewater samples |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6412874/ https://www.ncbi.nlm.nih.gov/pubmed/30769919 http://dx.doi.org/10.3390/molecules24040690 |
work_keys_str_mv | AT gonzalezhernandezprovidencia applicationofapillaredlayerzntriazolatemetalorganicframeworkinthedispersiveminiaturizedsolidphaseextractionofpersonalcareproductsfromwastewatersamples AT lagoanab applicationofapillaredlayerzntriazolatemetalorganicframeworkinthedispersiveminiaturizedsolidphaseextractionofpersonalcareproductsfromwastewatersamples AT pasanjorge applicationofapillaredlayerzntriazolatemetalorganicframeworkinthedispersiveminiaturizedsolidphaseextractionofpersonalcareproductsfromwastewatersamples AT ruizperezcatalina applicationofapillaredlayerzntriazolatemetalorganicframeworkinthedispersiveminiaturizedsolidphaseextractionofpersonalcareproductsfromwastewatersamples AT ayalajuanh applicationofapillaredlayerzntriazolatemetalorganicframeworkinthedispersiveminiaturizedsolidphaseextractionofpersonalcareproductsfromwastewatersamples AT afonsoanam applicationofapillaredlayerzntriazolatemetalorganicframeworkinthedispersiveminiaturizedsolidphaseextractionofpersonalcareproductsfromwastewatersamples AT pinoveronica applicationofapillaredlayerzntriazolatemetalorganicframeworkinthedispersiveminiaturizedsolidphaseextractionofpersonalcareproductsfromwastewatersamples |