The effect of respiratory motion on electronic portal imaging device dosimetry

There is an increasing need to develop methods for in vivo verification of the delivery of radiotherapy treatments. Electronic portal imaging devices (EPID's) have been demonstrated to be of use for this application. The basic principle is relatively straightforward, the EPID is used to measure...

Descripción completa

Detalles Bibliográficos
Autores principales: Fielding, Andrew L., Mendieta, Jessica Benitez, Maxwell, Sarah, Jones, Catherine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6414145/
https://www.ncbi.nlm.nih.gov/pubmed/30724011
http://dx.doi.org/10.1002/acm2.12541
_version_ 1783402935257923584
author Fielding, Andrew L.
Mendieta, Jessica Benitez
Maxwell, Sarah
Jones, Catherine
author_facet Fielding, Andrew L.
Mendieta, Jessica Benitez
Maxwell, Sarah
Jones, Catherine
author_sort Fielding, Andrew L.
collection PubMed
description There is an increasing need to develop methods for in vivo verification of the delivery of radiotherapy treatments. Electronic portal imaging devices (EPID's) have been demonstrated to be of use for this application. The basic principle is relatively straightforward, the EPID is used to measure a two‐dimensional (2D) planar exit or portal dose map behind the patient during the treatment delivery that can provide information on any errors in linear accelerator output or changes in the patient anatomy. In this paper we focused on the effect of intra‐fraction motion, particularly respiratory motion, on the measured 2D EPID dose–response. Measurements were made with a breast phantom undergoing one‐dimensional (1D) sinusoidal motion with a range of amplitudes (0.5, 1.0, and 1.5 cm) and frequencies (12, 15, and 20  cycles/min). Further measurements were made with the phantom undergoing breathing sequences measured during patient planning computed tomography simulation. We made use of the quadratic calibration method that converts the EPID images to a surrogate for dose, equivalent thickness of Plastic Water(®). Comparisons were made of the 2D thickness maps derived for the different motions compared to the static phantom case and the resulting dose difference analyzed over the “breast” region of interest. A 2D gamma analysis within the same region of interest was performed of the motion images compared to static reference image. Comparisons were made of 1D thickness profiles for the moving and static phantom. The 1D and 2D analyses show the method to be sensitive to the smallest motion amplitude of 0.5 cm tested in the phantom measurements. The results using the phantom demonstrate the method to be a potentially useful tool for monitoring intra‐fraction motion during the delivery of patient radiotherapy treatments as well as more generally providing information on the effects of motion on EPID based in vivo dosimetric verification.
format Online
Article
Text
id pubmed-6414145
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-64141452019-03-22 The effect of respiratory motion on electronic portal imaging device dosimetry Fielding, Andrew L. Mendieta, Jessica Benitez Maxwell, Sarah Jones, Catherine J Appl Clin Med Phys Radiation Oncology Physics There is an increasing need to develop methods for in vivo verification of the delivery of radiotherapy treatments. Electronic portal imaging devices (EPID's) have been demonstrated to be of use for this application. The basic principle is relatively straightforward, the EPID is used to measure a two‐dimensional (2D) planar exit or portal dose map behind the patient during the treatment delivery that can provide information on any errors in linear accelerator output or changes in the patient anatomy. In this paper we focused on the effect of intra‐fraction motion, particularly respiratory motion, on the measured 2D EPID dose–response. Measurements were made with a breast phantom undergoing one‐dimensional (1D) sinusoidal motion with a range of amplitudes (0.5, 1.0, and 1.5 cm) and frequencies (12, 15, and 20  cycles/min). Further measurements were made with the phantom undergoing breathing sequences measured during patient planning computed tomography simulation. We made use of the quadratic calibration method that converts the EPID images to a surrogate for dose, equivalent thickness of Plastic Water(®). Comparisons were made of the 2D thickness maps derived for the different motions compared to the static phantom case and the resulting dose difference analyzed over the “breast” region of interest. A 2D gamma analysis within the same region of interest was performed of the motion images compared to static reference image. Comparisons were made of 1D thickness profiles for the moving and static phantom. The 1D and 2D analyses show the method to be sensitive to the smallest motion amplitude of 0.5 cm tested in the phantom measurements. The results using the phantom demonstrate the method to be a potentially useful tool for monitoring intra‐fraction motion during the delivery of patient radiotherapy treatments as well as more generally providing information on the effects of motion on EPID based in vivo dosimetric verification. John Wiley and Sons Inc. 2019-02-05 /pmc/articles/PMC6414145/ /pubmed/30724011 http://dx.doi.org/10.1002/acm2.12541 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Fielding, Andrew L.
Mendieta, Jessica Benitez
Maxwell, Sarah
Jones, Catherine
The effect of respiratory motion on electronic portal imaging device dosimetry
title The effect of respiratory motion on electronic portal imaging device dosimetry
title_full The effect of respiratory motion on electronic portal imaging device dosimetry
title_fullStr The effect of respiratory motion on electronic portal imaging device dosimetry
title_full_unstemmed The effect of respiratory motion on electronic portal imaging device dosimetry
title_short The effect of respiratory motion on electronic portal imaging device dosimetry
title_sort effect of respiratory motion on electronic portal imaging device dosimetry
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6414145/
https://www.ncbi.nlm.nih.gov/pubmed/30724011
http://dx.doi.org/10.1002/acm2.12541
work_keys_str_mv AT fieldingandrewl theeffectofrespiratorymotiononelectronicportalimagingdevicedosimetry
AT mendietajessicabenitez theeffectofrespiratorymotiononelectronicportalimagingdevicedosimetry
AT maxwellsarah theeffectofrespiratorymotiononelectronicportalimagingdevicedosimetry
AT jonescatherine theeffectofrespiratorymotiononelectronicportalimagingdevicedosimetry
AT fieldingandrewl effectofrespiratorymotiononelectronicportalimagingdevicedosimetry
AT mendietajessicabenitez effectofrespiratorymotiononelectronicportalimagingdevicedosimetry
AT maxwellsarah effectofrespiratorymotiononelectronicportalimagingdevicedosimetry
AT jonescatherine effectofrespiratorymotiononelectronicportalimagingdevicedosimetry