Cargando…

MR‐based treatment planning in radiation therapy using a deep learning approach

PURPOSE: To develop and evaluate the feasibility of deep learning approaches for MR‐based treatment planning (deepMTP) in brain tumor radiation therapy. METHODS AND MATERIALS: A treatment planning pipeline was constructed using a deep learning approach to generate continuously valued pseudo CT image...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Fang, Yadav, Poonam, Baschnagel, Andrew M., McMillan, Alan B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6414148/
https://www.ncbi.nlm.nih.gov/pubmed/30861275
http://dx.doi.org/10.1002/acm2.12554
_version_ 1783402935955226624
author Liu, Fang
Yadav, Poonam
Baschnagel, Andrew M.
McMillan, Alan B.
author_facet Liu, Fang
Yadav, Poonam
Baschnagel, Andrew M.
McMillan, Alan B.
author_sort Liu, Fang
collection PubMed
description PURPOSE: To develop and evaluate the feasibility of deep learning approaches for MR‐based treatment planning (deepMTP) in brain tumor radiation therapy. METHODS AND MATERIALS: A treatment planning pipeline was constructed using a deep learning approach to generate continuously valued pseudo CT images from MR images. A deep convolutional neural network was designed to identify tissue features in volumetric head MR images training with co‐registered kVCT images. A set of 40 retrospective 3D T1‐weighted head images was utilized to train the model, and evaluated in 10 clinical cases with brain metastases by comparing treatment plans using deep learning generated pseudo CT and using an acquired planning kVCT. Paired‐sample Wilcoxon signed rank sum tests were used for statistical analysis to compare dosimetric parameters of plans made with pseudo CT images generated from deepMTP to those made with kVCT‐based clinical treatment plan (CTTP). RESULTS: deepMTP provides an accurate pseudo CT with Dice coefficients for air: 0.95 ± 0.01, soft tissue: 0.94 ± 0.02, and bone: 0.85 ± 0.02 and a mean absolute error of 75 ± 23 HU compared with acquired kVCTs. The absolute percentage differences of dosimetric parameters between deepMTP and CTTP was 0.24% ± 0.46% for planning target volume (PTV) volume, 1.39% ± 1.31% for maximum dose and 0.27% ± 0.79% for the PTV receiving 95% of the prescribed dose (V95). Furthermore, no significant difference was found for PTV volume (P = 0.50), the maximum dose (P = 0.83) and V95 (P = 0.19) between deepMTP and CTTP. CONCLUSIONS: We have developed an automated approach (deepMTP) that allows generation of a continuously valued pseudo CT from a single high‐resolution 3D MR image and evaluated it in partial brain tumor treatment planning. The deepMTP provided dose distribution with no significant difference relative to a kVCT‐based standard volumetric modulated arc therapy plans.
format Online
Article
Text
id pubmed-6414148
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-64141482019-03-22 MR‐based treatment planning in radiation therapy using a deep learning approach Liu, Fang Yadav, Poonam Baschnagel, Andrew M. McMillan, Alan B. J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: To develop and evaluate the feasibility of deep learning approaches for MR‐based treatment planning (deepMTP) in brain tumor radiation therapy. METHODS AND MATERIALS: A treatment planning pipeline was constructed using a deep learning approach to generate continuously valued pseudo CT images from MR images. A deep convolutional neural network was designed to identify tissue features in volumetric head MR images training with co‐registered kVCT images. A set of 40 retrospective 3D T1‐weighted head images was utilized to train the model, and evaluated in 10 clinical cases with brain metastases by comparing treatment plans using deep learning generated pseudo CT and using an acquired planning kVCT. Paired‐sample Wilcoxon signed rank sum tests were used for statistical analysis to compare dosimetric parameters of plans made with pseudo CT images generated from deepMTP to those made with kVCT‐based clinical treatment plan (CTTP). RESULTS: deepMTP provides an accurate pseudo CT with Dice coefficients for air: 0.95 ± 0.01, soft tissue: 0.94 ± 0.02, and bone: 0.85 ± 0.02 and a mean absolute error of 75 ± 23 HU compared with acquired kVCTs. The absolute percentage differences of dosimetric parameters between deepMTP and CTTP was 0.24% ± 0.46% for planning target volume (PTV) volume, 1.39% ± 1.31% for maximum dose and 0.27% ± 0.79% for the PTV receiving 95% of the prescribed dose (V95). Furthermore, no significant difference was found for PTV volume (P = 0.50), the maximum dose (P = 0.83) and V95 (P = 0.19) between deepMTP and CTTP. CONCLUSIONS: We have developed an automated approach (deepMTP) that allows generation of a continuously valued pseudo CT from a single high‐resolution 3D MR image and evaluated it in partial brain tumor treatment planning. The deepMTP provided dose distribution with no significant difference relative to a kVCT‐based standard volumetric modulated arc therapy plans. John Wiley and Sons Inc. 2019-03-12 /pmc/articles/PMC6414148/ /pubmed/30861275 http://dx.doi.org/10.1002/acm2.12554 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Liu, Fang
Yadav, Poonam
Baschnagel, Andrew M.
McMillan, Alan B.
MR‐based treatment planning in radiation therapy using a deep learning approach
title MR‐based treatment planning in radiation therapy using a deep learning approach
title_full MR‐based treatment planning in radiation therapy using a deep learning approach
title_fullStr MR‐based treatment planning in radiation therapy using a deep learning approach
title_full_unstemmed MR‐based treatment planning in radiation therapy using a deep learning approach
title_short MR‐based treatment planning in radiation therapy using a deep learning approach
title_sort mr‐based treatment planning in radiation therapy using a deep learning approach
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6414148/
https://www.ncbi.nlm.nih.gov/pubmed/30861275
http://dx.doi.org/10.1002/acm2.12554
work_keys_str_mv AT liufang mrbasedtreatmentplanninginradiationtherapyusingadeeplearningapproach
AT yadavpoonam mrbasedtreatmentplanninginradiationtherapyusingadeeplearningapproach
AT baschnagelandrewm mrbasedtreatmentplanninginradiationtherapyusingadeeplearningapproach
AT mcmillanalanb mrbasedtreatmentplanninginradiationtherapyusingadeeplearningapproach