Cargando…

Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy

We evaluated an EPID‐based in‐vivo dosimetry (IVD) method for the dose verification and the treatment reproducibility of lung SBRT‐VMAT treatments in clinical routine. Ten patients with lung metastases treated with Elekta VMAT technique were enrolled. All patients were irradiated in five consecutive...

Descripción completa

Detalles Bibliográficos
Autores principales: Cilla, Savino, Ianiro, Anna, Craus, Maurizio, Viola, Pietro, Deodato, Francesco, Macchia, Gabriella, Buwenge, Milly, Morganti, Alessio G., Valentini, Vincenzo, Piermattei, Angelo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6414179/
https://www.ncbi.nlm.nih.gov/pubmed/30790439
http://dx.doi.org/10.1002/acm2.12538
_version_ 1783402943250169856
author Cilla, Savino
Ianiro, Anna
Craus, Maurizio
Viola, Pietro
Deodato, Francesco
Macchia, Gabriella
Buwenge, Milly
Morganti, Alessio G.
Valentini, Vincenzo
Piermattei, Angelo
author_facet Cilla, Savino
Ianiro, Anna
Craus, Maurizio
Viola, Pietro
Deodato, Francesco
Macchia, Gabriella
Buwenge, Milly
Morganti, Alessio G.
Valentini, Vincenzo
Piermattei, Angelo
author_sort Cilla, Savino
collection PubMed
description We evaluated an EPID‐based in‐vivo dosimetry (IVD) method for the dose verification and the treatment reproducibility of lung SBRT‐VMAT treatments in clinical routine. Ten patients with lung metastases treated with Elekta VMAT technique were enrolled. All patients were irradiated in five consecutive fractions, with total doses of 50 Gy. Set‐up was carried out with the Elekta stereotactic body frame. Eight patients were simulated and treated using the Active Breath Control (ABC) system, a spirometer enabling patients to maintain a breath‐hold at a predetermined lung volume. Two patients were simulated and treated in free‐breathing using an abdominal compressor. IVD was performed using the SOFTDISO software. IVD tests were evaluated by means of (a) ratio R between daily in‐vivo isocenter dose and planned dose and (b) γ‐analysis between EPID integral portal images in terms of percentage of points with γ‐value smaller than one (γ (%)) and mean γ‐values (γ (mean)) using a 3%(global)/3 mm criteria. Alert criteria of ±5% for R ratio, γ (%) < 90%, and γ (mean) > 0.67 were chosen. 50 transit EPID images were acquired. For the patients treated with ABC spirometer, the results reported a high level of accuracy in dose delivery with 100% of tests within ±5%. The γ‐analysis showed a mean value of γ (mean) equal to 0.21 (range: 0.04–0.56) and a mean γ (%) equal to 96.9 (range: 78–100). Relevant discrepancies were observed only for the two patients treated without ABC, mainly due to a blurring dose effect due to residual respiratory motion. Our method provided a fast and accurate procedure in clinical routine for verifying delivered dose as well as for detecting errors.
format Online
Article
Text
id pubmed-6414179
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-64141792019-03-22 Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy Cilla, Savino Ianiro, Anna Craus, Maurizio Viola, Pietro Deodato, Francesco Macchia, Gabriella Buwenge, Milly Morganti, Alessio G. Valentini, Vincenzo Piermattei, Angelo J Appl Clin Med Phys Radiation Oncology Physics We evaluated an EPID‐based in‐vivo dosimetry (IVD) method for the dose verification and the treatment reproducibility of lung SBRT‐VMAT treatments in clinical routine. Ten patients with lung metastases treated with Elekta VMAT technique were enrolled. All patients were irradiated in five consecutive fractions, with total doses of 50 Gy. Set‐up was carried out with the Elekta stereotactic body frame. Eight patients were simulated and treated using the Active Breath Control (ABC) system, a spirometer enabling patients to maintain a breath‐hold at a predetermined lung volume. Two patients were simulated and treated in free‐breathing using an abdominal compressor. IVD was performed using the SOFTDISO software. IVD tests were evaluated by means of (a) ratio R between daily in‐vivo isocenter dose and planned dose and (b) γ‐analysis between EPID integral portal images in terms of percentage of points with γ‐value smaller than one (γ (%)) and mean γ‐values (γ (mean)) using a 3%(global)/3 mm criteria. Alert criteria of ±5% for R ratio, γ (%) < 90%, and γ (mean) > 0.67 were chosen. 50 transit EPID images were acquired. For the patients treated with ABC spirometer, the results reported a high level of accuracy in dose delivery with 100% of tests within ±5%. The γ‐analysis showed a mean value of γ (mean) equal to 0.21 (range: 0.04–0.56) and a mean γ (%) equal to 96.9 (range: 78–100). Relevant discrepancies were observed only for the two patients treated without ABC, mainly due to a blurring dose effect due to residual respiratory motion. Our method provided a fast and accurate procedure in clinical routine for verifying delivered dose as well as for detecting errors. John Wiley and Sons Inc. 2019-02-20 /pmc/articles/PMC6414179/ /pubmed/30790439 http://dx.doi.org/10.1002/acm2.12538 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Cilla, Savino
Ianiro, Anna
Craus, Maurizio
Viola, Pietro
Deodato, Francesco
Macchia, Gabriella
Buwenge, Milly
Morganti, Alessio G.
Valentini, Vincenzo
Piermattei, Angelo
Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy
title Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy
title_full Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy
title_fullStr Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy
title_full_unstemmed Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy
title_short Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy
title_sort epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6414179/
https://www.ncbi.nlm.nih.gov/pubmed/30790439
http://dx.doi.org/10.1002/acm2.12538
work_keys_str_mv AT cillasavino epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy
AT ianiroanna epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy
AT crausmaurizio epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy
AT violapietro epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy
AT deodatofrancesco epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy
AT macchiagabriella epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy
AT buwengemilly epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy
AT morgantialessiog epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy
AT valentinivincenzo epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy
AT piermatteiangelo epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy