Cargando…
Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy
We evaluated an EPID‐based in‐vivo dosimetry (IVD) method for the dose verification and the treatment reproducibility of lung SBRT‐VMAT treatments in clinical routine. Ten patients with lung metastases treated with Elekta VMAT technique were enrolled. All patients were irradiated in five consecutive...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6414179/ https://www.ncbi.nlm.nih.gov/pubmed/30790439 http://dx.doi.org/10.1002/acm2.12538 |
_version_ | 1783402943250169856 |
---|---|
author | Cilla, Savino Ianiro, Anna Craus, Maurizio Viola, Pietro Deodato, Francesco Macchia, Gabriella Buwenge, Milly Morganti, Alessio G. Valentini, Vincenzo Piermattei, Angelo |
author_facet | Cilla, Savino Ianiro, Anna Craus, Maurizio Viola, Pietro Deodato, Francesco Macchia, Gabriella Buwenge, Milly Morganti, Alessio G. Valentini, Vincenzo Piermattei, Angelo |
author_sort | Cilla, Savino |
collection | PubMed |
description | We evaluated an EPID‐based in‐vivo dosimetry (IVD) method for the dose verification and the treatment reproducibility of lung SBRT‐VMAT treatments in clinical routine. Ten patients with lung metastases treated with Elekta VMAT technique were enrolled. All patients were irradiated in five consecutive fractions, with total doses of 50 Gy. Set‐up was carried out with the Elekta stereotactic body frame. Eight patients were simulated and treated using the Active Breath Control (ABC) system, a spirometer enabling patients to maintain a breath‐hold at a predetermined lung volume. Two patients were simulated and treated in free‐breathing using an abdominal compressor. IVD was performed using the SOFTDISO software. IVD tests were evaluated by means of (a) ratio R between daily in‐vivo isocenter dose and planned dose and (b) γ‐analysis between EPID integral portal images in terms of percentage of points with γ‐value smaller than one (γ (%)) and mean γ‐values (γ (mean)) using a 3%(global)/3 mm criteria. Alert criteria of ±5% for R ratio, γ (%) < 90%, and γ (mean) > 0.67 were chosen. 50 transit EPID images were acquired. For the patients treated with ABC spirometer, the results reported a high level of accuracy in dose delivery with 100% of tests within ±5%. The γ‐analysis showed a mean value of γ (mean) equal to 0.21 (range: 0.04–0.56) and a mean γ (%) equal to 96.9 (range: 78–100). Relevant discrepancies were observed only for the two patients treated without ABC, mainly due to a blurring dose effect due to residual respiratory motion. Our method provided a fast and accurate procedure in clinical routine for verifying delivered dose as well as for detecting errors. |
format | Online Article Text |
id | pubmed-6414179 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-64141792019-03-22 Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy Cilla, Savino Ianiro, Anna Craus, Maurizio Viola, Pietro Deodato, Francesco Macchia, Gabriella Buwenge, Milly Morganti, Alessio G. Valentini, Vincenzo Piermattei, Angelo J Appl Clin Med Phys Radiation Oncology Physics We evaluated an EPID‐based in‐vivo dosimetry (IVD) method for the dose verification and the treatment reproducibility of lung SBRT‐VMAT treatments in clinical routine. Ten patients with lung metastases treated with Elekta VMAT technique were enrolled. All patients were irradiated in five consecutive fractions, with total doses of 50 Gy. Set‐up was carried out with the Elekta stereotactic body frame. Eight patients were simulated and treated using the Active Breath Control (ABC) system, a spirometer enabling patients to maintain a breath‐hold at a predetermined lung volume. Two patients were simulated and treated in free‐breathing using an abdominal compressor. IVD was performed using the SOFTDISO software. IVD tests were evaluated by means of (a) ratio R between daily in‐vivo isocenter dose and planned dose and (b) γ‐analysis between EPID integral portal images in terms of percentage of points with γ‐value smaller than one (γ (%)) and mean γ‐values (γ (mean)) using a 3%(global)/3 mm criteria. Alert criteria of ±5% for R ratio, γ (%) < 90%, and γ (mean) > 0.67 were chosen. 50 transit EPID images were acquired. For the patients treated with ABC spirometer, the results reported a high level of accuracy in dose delivery with 100% of tests within ±5%. The γ‐analysis showed a mean value of γ (mean) equal to 0.21 (range: 0.04–0.56) and a mean γ (%) equal to 96.9 (range: 78–100). Relevant discrepancies were observed only for the two patients treated without ABC, mainly due to a blurring dose effect due to residual respiratory motion. Our method provided a fast and accurate procedure in clinical routine for verifying delivered dose as well as for detecting errors. John Wiley and Sons Inc. 2019-02-20 /pmc/articles/PMC6414179/ /pubmed/30790439 http://dx.doi.org/10.1002/acm2.12538 Text en © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Cilla, Savino Ianiro, Anna Craus, Maurizio Viola, Pietro Deodato, Francesco Macchia, Gabriella Buwenge, Milly Morganti, Alessio G. Valentini, Vincenzo Piermattei, Angelo Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy |
title | Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy |
title_full | Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy |
title_fullStr | Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy |
title_full_unstemmed | Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy |
title_short | Epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy |
title_sort | epid‐based in vivo dose verification for lung stereotactic treatments delivered with multiple breath‐hold segmented volumetric modulated arc therapy |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6414179/ https://www.ncbi.nlm.nih.gov/pubmed/30790439 http://dx.doi.org/10.1002/acm2.12538 |
work_keys_str_mv | AT cillasavino epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy AT ianiroanna epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy AT crausmaurizio epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy AT violapietro epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy AT deodatofrancesco epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy AT macchiagabriella epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy AT buwengemilly epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy AT morgantialessiog epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy AT valentinivincenzo epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy AT piermatteiangelo epidbasedinvivodoseverificationforlungstereotactictreatmentsdeliveredwithmultiplebreathholdsegmentedvolumetricmodulatedarctherapy |