Cargando…
Inappropriately Firing Defibrillator: A Simulation Case for Emergency Medicine Residents
INTRODUCTION: Emergency physicians must be able to manage inappropriately firing defibrillators. Many physicians may not experience this high-risk, low-frequency patient presentation during residency. We created this simulation to increase residents' knowledge of basic defibrillator function an...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Association of American Medical Colleges
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6415004/ https://www.ncbi.nlm.nih.gov/pubmed/30931387 http://dx.doi.org/10.15766/mep_2374-8265.10808 |
Sumario: | INTRODUCTION: Emergency physicians must be able to manage inappropriately firing defibrillators. Many physicians may not experience this high-risk, low-frequency patient presentation during residency. We created this simulation to increase residents' knowledge of basic defibrillator function and confidence in managing patients with malfunctioning defibrillators. METHODS: Sixteen emergency medicine residents of all levels of training participated in this curriculum. The educational experience began with a lecture. Residents then managed the simulated patient encounter in groups of four. The patient was a 63-year-old male presenting after feeling his defibrillator fire. He was found to have a supraventricular tachycardia with an inappropriately firing defibrillator. Learners needed to recognize the inappropriately firing defibrillator, inactivate it with a magnet, and treat the arrhythmia. Implementation of this scenario required audiovisual equipment and a simulation room equipped with high-fidelity simulator, patient monitor, code cart, defibrillator, and pacemaker magnet. Learners completed pre- and postcourse surveys to assess changes in baseline knowledge of defibrillator function and self-reported confidence in managing these complicated patients. RESULTS: After participating in this educational intervention, residents improved their performance on a 10-question quiz from a class mean of 60% to 84% (p < .001). Residents also exhibited an increase in self-reported confidence in managing patients with inappropriately firing defibrillators (p < .001) and in knowing when to place a magnet over a patient's defibrillator (p < .001). DISCUSSION: Residents demonstrated increased knowledge of defibrillator function as well as increased confidence in managing patients with malfunctioning defibrillators after participating in this simulation experience. |
---|