Cargando…
Affinity Capillary Electrochromatography of Molecularly Imprinted Thin Layers Grafted onto Silica Capillaries Using a Surface-Bound Azo-Initiator and Living Polymerization
Molecularly imprinted thin layers were prepared in silica capillaries by using two different surface polymerization strategies, the first using 4,4′-azobis(4-cyanovaleric acid) as a surface-coupled radical initiator, and the second, S-carboxypropyl-S’-benzyltrithiocarbonate as a reversible addition-...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6415351/ https://www.ncbi.nlm.nih.gov/pubmed/30966228 http://dx.doi.org/10.3390/polym10020192 |
_version_ | 1783403167860391936 |
---|---|
author | Giovannoli, Cristina Passini, Cinzia Di Nardo, Fabio Anfossi, Laura Baggiani, Claudio Nicholls, Ian A. |
author_facet | Giovannoli, Cristina Passini, Cinzia Di Nardo, Fabio Anfossi, Laura Baggiani, Claudio Nicholls, Ian A. |
author_sort | Giovannoli, Cristina |
collection | PubMed |
description | Molecularly imprinted thin layers were prepared in silica capillaries by using two different surface polymerization strategies, the first using 4,4′-azobis(4-cyanovaleric acid) as a surface-coupled radical initiator, and the second, S-carboxypropyl-S’-benzyltrithiocarbonate as a reversible addition-fragmentation chain transfer (RAFT) agent in combination with 2,2′-azobisisobutyronitrile as a free radical initiator. The ability to generate imprinted thin layers was tested on two different polymerization systems: (i) a 4-vinylpyridine/ethylene dimethacrylate (4VP-EDMA) in methanol-water solution with 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) as a template; and (ii) methacrylic acid/ethylene dimethacrylate (MAA-EDMA) in a chloroform solution with warfarin as the template molecule. The binding properties of the imprinted capillaries were studied and compared with those of the corresponding non-imprinted polymer coated capillaries by injecting the template molecule and by measuring its migration times relative to a neutral and non-retained marker. The role of running buffer hydrophobicity on recognition was investigated by studying the influence of varying buffer acetonitrile concentration. The 2,4,5-T-imprinted capillary showed molecular recognition based on a reversed phase mechanism, with a decrease of the template recognition in the presence of higher acetonitrile content; whereas warfarin-imprinted capillaries showed a bell-shaped trend upon varying the acetonitrile percentage, illustrating different mechanisms underlying imprinted polymer-ligand recognition. Importantly, the results demonstrated the validity of affinity capillary electrochromatography (CEC) to screen the binding properties of imprinted layers. |
format | Online Article Text |
id | pubmed-6415351 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64153512019-04-02 Affinity Capillary Electrochromatography of Molecularly Imprinted Thin Layers Grafted onto Silica Capillaries Using a Surface-Bound Azo-Initiator and Living Polymerization Giovannoli, Cristina Passini, Cinzia Di Nardo, Fabio Anfossi, Laura Baggiani, Claudio Nicholls, Ian A. Polymers (Basel) Article Molecularly imprinted thin layers were prepared in silica capillaries by using two different surface polymerization strategies, the first using 4,4′-azobis(4-cyanovaleric acid) as a surface-coupled radical initiator, and the second, S-carboxypropyl-S’-benzyltrithiocarbonate as a reversible addition-fragmentation chain transfer (RAFT) agent in combination with 2,2′-azobisisobutyronitrile as a free radical initiator. The ability to generate imprinted thin layers was tested on two different polymerization systems: (i) a 4-vinylpyridine/ethylene dimethacrylate (4VP-EDMA) in methanol-water solution with 2,4,5-trichlorophenoxyacetic acid (2,4,5-T) as a template; and (ii) methacrylic acid/ethylene dimethacrylate (MAA-EDMA) in a chloroform solution with warfarin as the template molecule. The binding properties of the imprinted capillaries were studied and compared with those of the corresponding non-imprinted polymer coated capillaries by injecting the template molecule and by measuring its migration times relative to a neutral and non-retained marker. The role of running buffer hydrophobicity on recognition was investigated by studying the influence of varying buffer acetonitrile concentration. The 2,4,5-T-imprinted capillary showed molecular recognition based on a reversed phase mechanism, with a decrease of the template recognition in the presence of higher acetonitrile content; whereas warfarin-imprinted capillaries showed a bell-shaped trend upon varying the acetonitrile percentage, illustrating different mechanisms underlying imprinted polymer-ligand recognition. Importantly, the results demonstrated the validity of affinity capillary electrochromatography (CEC) to screen the binding properties of imprinted layers. MDPI 2018-02-15 /pmc/articles/PMC6415351/ /pubmed/30966228 http://dx.doi.org/10.3390/polym10020192 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Giovannoli, Cristina Passini, Cinzia Di Nardo, Fabio Anfossi, Laura Baggiani, Claudio Nicholls, Ian A. Affinity Capillary Electrochromatography of Molecularly Imprinted Thin Layers Grafted onto Silica Capillaries Using a Surface-Bound Azo-Initiator and Living Polymerization |
title | Affinity Capillary Electrochromatography of Molecularly Imprinted Thin Layers Grafted onto Silica Capillaries Using a Surface-Bound Azo-Initiator and Living Polymerization |
title_full | Affinity Capillary Electrochromatography of Molecularly Imprinted Thin Layers Grafted onto Silica Capillaries Using a Surface-Bound Azo-Initiator and Living Polymerization |
title_fullStr | Affinity Capillary Electrochromatography of Molecularly Imprinted Thin Layers Grafted onto Silica Capillaries Using a Surface-Bound Azo-Initiator and Living Polymerization |
title_full_unstemmed | Affinity Capillary Electrochromatography of Molecularly Imprinted Thin Layers Grafted onto Silica Capillaries Using a Surface-Bound Azo-Initiator and Living Polymerization |
title_short | Affinity Capillary Electrochromatography of Molecularly Imprinted Thin Layers Grafted onto Silica Capillaries Using a Surface-Bound Azo-Initiator and Living Polymerization |
title_sort | affinity capillary electrochromatography of molecularly imprinted thin layers grafted onto silica capillaries using a surface-bound azo-initiator and living polymerization |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6415351/ https://www.ncbi.nlm.nih.gov/pubmed/30966228 http://dx.doi.org/10.3390/polym10020192 |
work_keys_str_mv | AT giovannolicristina affinitycapillaryelectrochromatographyofmolecularlyimprintedthinlayersgraftedontosilicacapillariesusingasurfaceboundazoinitiatorandlivingpolymerization AT passinicinzia affinitycapillaryelectrochromatographyofmolecularlyimprintedthinlayersgraftedontosilicacapillariesusingasurfaceboundazoinitiatorandlivingpolymerization AT dinardofabio affinitycapillaryelectrochromatographyofmolecularlyimprintedthinlayersgraftedontosilicacapillariesusingasurfaceboundazoinitiatorandlivingpolymerization AT anfossilaura affinitycapillaryelectrochromatographyofmolecularlyimprintedthinlayersgraftedontosilicacapillariesusingasurfaceboundazoinitiatorandlivingpolymerization AT baggianiclaudio affinitycapillaryelectrochromatographyofmolecularlyimprintedthinlayersgraftedontosilicacapillariesusingasurfaceboundazoinitiatorandlivingpolymerization AT nichollsiana affinitycapillaryelectrochromatographyofmolecularlyimprintedthinlayersgraftedontosilicacapillariesusingasurfaceboundazoinitiatorandlivingpolymerization |