Cargando…

Comparative outcomes of subcutaneous and transvenous cardioverter-defibrillators

BACKGROUND: The comparative outcomes of subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous ICD (T-ICD) have not been well studied. The aim of this study was to evaluate the safety and efficacy of currently available S-ICD and T-ICD. METHODS: The study included 86 patients wh...

Descripción completa

Detalles Bibliográficos
Autores principales: Liang, Jin-Jun, Okamura, Hideo, Asirvatham, Roshini, Schneider, Andrew, Hodge, David O., Yang, Mei, Li, Xu-Ping, Dai, Ming-Yan, Tian, Ying, Zhang, Pei, Cannon, Bryan C., Huang, Cong-Xin, Friedman, Paul A., Cha, Yong-Mei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6416025/
https://www.ncbi.nlm.nih.gov/pubmed/30855343
http://dx.doi.org/10.1097/CM9.0000000000000133
Descripción
Sumario:BACKGROUND: The comparative outcomes of subcutaneous implantable cardioverter-defibrillator (S-ICD) and transvenous ICD (T-ICD) have not been well studied. The aim of this study was to evaluate the safety and efficacy of currently available S-ICD and T-ICD. METHODS: The study included 86 patients who received an S-ICD and 1:1 matched to those who received single-chamber T-ICD by gender, age, diagnosis, left ventricular ejection fraction (LVEF), and implant year. The clinical outcomes and implant complications were compared between the two groups. RESULTS: The mean age of the 172 patients was 45 years, and 129 (75%) were male. The most common cardiac condition was hypertrophic cardiomyopathy (HCM, 37.8%). The mean LVEF was 50%. At a mean follow-up of 23 months, the appropriate and inappropriate ICD therapy rate were 1.2% vs. 4.7% (χ (2) = 1.854, P = 0.368) and 9.3% vs. 3.5% (χ (2) = 2.428, P = 0.211) in S-ICD and T-ICD groups respectively. There were no significant differences in device-related major and minor complications between the two groups (7.0% vs. 3.5%, χ (2) = 1.055, P = 0.496). The S-ICD group had higher T-wave oversensing than T-ICD group (9.3% vs. 0%, χ (2) = 8.390, P = 0.007). Sixty-five patients had HCM (32 in S-ICD and 33 in T-ICD). The incidence of major complications was not significantly different between the two groups. CONCLUSIONS: The efficacy of an S-ICD is comparable to that of T-ICD, especially in a dominantly HCM patient population. The S-ICD is associated with fewer major complications demanding reoperation.