Cargando…

A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner

In this report we have evaluated radiation effective dose received by patients during ECG-gated CCTA examinations based on gender, heart rate, tube voltage protocol and body mass index (BMI). A total of 1,824 patients were retrospectively recruited (1,139 men and 685 women) and they were divided int...

Descripción completa

Detalles Bibliográficos
Autores principales: Sabarudin, Akmal, Siong, Tiong Wei, Chin, Ang Wee, Hoong, Ng Kwan, Karim, Muhammad Khalis Abdul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6416329/
https://www.ncbi.nlm.nih.gov/pubmed/30867480
http://dx.doi.org/10.1038/s41598-019-40758-5
_version_ 1783403335448002560
author Sabarudin, Akmal
Siong, Tiong Wei
Chin, Ang Wee
Hoong, Ng Kwan
Karim, Muhammad Khalis Abdul
author_facet Sabarudin, Akmal
Siong, Tiong Wei
Chin, Ang Wee
Hoong, Ng Kwan
Karim, Muhammad Khalis Abdul
author_sort Sabarudin, Akmal
collection PubMed
description In this report we have evaluated radiation effective dose received by patients during ECG-gated CCTA examinations based on gender, heart rate, tube voltage protocol and body mass index (BMI). A total of 1,824 patients were retrospectively recruited (1,139 men and 685 women) and they were divided into Group 1 (CCTA with calcium scoring), Group 2 (CCTA without calcium scoring) and Group 3 (only calcium scoring), where the association between gender, heart rate, tube voltage protocol and body mass index (BMI) were analysed. Examinations were performed using a retrospective ECG-gated CCTA protocol and the effective doses were calculated from the dose length product with a conversion coefficient of 0.026 mSv.mGy(−1)cm(−1). No significant differences were observed in the mean effective dose between gender in all groups. The mean estimated dose was significantly higher when the heart rate was lower in Group 1 (p < 0.001) and Group 2 (p = 0.002). There were also significant differences between the mean effective dose in tube voltage protocol and BMI among the three groups. The mean effective dose was positively correlated with BMI (p < 0.001), but inversely related to the heart rate. This study supported the theory that a high heart rate, low tube voltage and low BMI could significantly reduce radiation dose exposure.
format Online
Article
Text
id pubmed-6416329
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-64163292019-03-15 A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner Sabarudin, Akmal Siong, Tiong Wei Chin, Ang Wee Hoong, Ng Kwan Karim, Muhammad Khalis Abdul Sci Rep Article In this report we have evaluated radiation effective dose received by patients during ECG-gated CCTA examinations based on gender, heart rate, tube voltage protocol and body mass index (BMI). A total of 1,824 patients were retrospectively recruited (1,139 men and 685 women) and they were divided into Group 1 (CCTA with calcium scoring), Group 2 (CCTA without calcium scoring) and Group 3 (only calcium scoring), where the association between gender, heart rate, tube voltage protocol and body mass index (BMI) were analysed. Examinations were performed using a retrospective ECG-gated CCTA protocol and the effective doses were calculated from the dose length product with a conversion coefficient of 0.026 mSv.mGy(−1)cm(−1). No significant differences were observed in the mean effective dose between gender in all groups. The mean estimated dose was significantly higher when the heart rate was lower in Group 1 (p < 0.001) and Group 2 (p = 0.002). There were also significant differences between the mean effective dose in tube voltage protocol and BMI among the three groups. The mean effective dose was positively correlated with BMI (p < 0.001), but inversely related to the heart rate. This study supported the theory that a high heart rate, low tube voltage and low BMI could significantly reduce radiation dose exposure. Nature Publishing Group UK 2019-03-13 /pmc/articles/PMC6416329/ /pubmed/30867480 http://dx.doi.org/10.1038/s41598-019-40758-5 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Sabarudin, Akmal
Siong, Tiong Wei
Chin, Ang Wee
Hoong, Ng Kwan
Karim, Muhammad Khalis Abdul
A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner
title A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner
title_full A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner
title_fullStr A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner
title_full_unstemmed A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner
title_short A comparison study of radiation effective dose in ECG-Gated Coronary CT Angiography and calcium scoring examinations performed with a dual-source CT scanner
title_sort comparison study of radiation effective dose in ecg-gated coronary ct angiography and calcium scoring examinations performed with a dual-source ct scanner
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6416329/
https://www.ncbi.nlm.nih.gov/pubmed/30867480
http://dx.doi.org/10.1038/s41598-019-40758-5
work_keys_str_mv AT sabarudinakmal acomparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner
AT siongtiongwei acomparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner
AT chinangwee acomparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner
AT hoongngkwan acomparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner
AT karimmuhammadkhalisabdul acomparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner
AT sabarudinakmal comparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner
AT siongtiongwei comparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner
AT chinangwee comparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner
AT hoongngkwan comparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner
AT karimmuhammadkhalisabdul comparisonstudyofradiationeffectivedoseinecggatedcoronaryctangiographyandcalciumscoringexaminationsperformedwithadualsourcectscanner