Cargando…

Image reconstruction utilizing median filtering applied to elastography

BACKGROUND: The resources of ultrafast technology can be used to add another analysis to ultrasound imaging: assessment of tissue viscoelasticity. Ultrafast image formation can be utilized to find transitory shear waves propagating in soft tissue, which permits quantification of the mechanical prope...

Descripción completa

Detalles Bibliográficos
Autores principales: Carbente, Rubem P., Maia, Joaquim M., Assef, Amauri A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6417019/
https://www.ncbi.nlm.nih.gov/pubmed/30866955
http://dx.doi.org/10.1186/s12938-019-0641-6
_version_ 1783403479655514112
author Carbente, Rubem P.
Maia, Joaquim M.
Assef, Amauri A.
author_facet Carbente, Rubem P.
Maia, Joaquim M.
Assef, Amauri A.
author_sort Carbente, Rubem P.
collection PubMed
description BACKGROUND: The resources of ultrafast technology can be used to add another analysis to ultrasound imaging: assessment of tissue viscoelasticity. Ultrafast image formation can be utilized to find transitory shear waves propagating in soft tissue, which permits quantification of the mechanical properties of the tissue via elastography. This technique permits simple and noninvasive diagnosis and monitoring of disease. METHODS: This article presents a method to estimate the viscoelastic properties and rigidity of structures using the ultrasound technique known as shear wave elasticity imaging (SWEI). The Verasonics Vantage 128 research platform and L11-4v transducer were used to acquire radio frequency signals from a model 049A elastography phantom (CIRS, USA), with subsequent processing and analysis in MATLAB. RESULTS: The images and indexes obtained reflect the qualitative measurements of the different regions of inclusions in the phantom and the respective alterations in the viscoelastic properties of distinct areas. Comparison of the results obtained with this proposed technique and other commonly used techniques demonstrates the characteristics of median filtering in smoothing variations in velocity to form elastographic images. The results from the technique proposed in this study are within the margins of error indicated by the phantom manufacturer for each type of inclusion; for the phantom base and for type I, II, III, and IV inclusions, respectively, in kPa and percentage errors, these are 25 (24.0%), 8 (37.5%), 14 (28.6%), 45 (17.8%), and 80 (15.0%). The values obtained using the method proposed in this study and mean percentage errors were 29.18 (− 16.7%), 10.26 (− 28.2%), 15.64 (− 11.7%), 45.81 (− 1.8%), and 85.21 (− 6.5%), respectively. CONCLUSIONS: The new technique to obtain images uses a distinct filtering function which considers the mean velocity in the region around each pixel, in turn allowing adjustments according to the characteristics of the phantom inclusions within the ultrasound and optimizing the resulting elastographic images.
format Online
Article
Text
id pubmed-6417019
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-64170192019-03-25 Image reconstruction utilizing median filtering applied to elastography Carbente, Rubem P. Maia, Joaquim M. Assef, Amauri A. Biomed Eng Online Research BACKGROUND: The resources of ultrafast technology can be used to add another analysis to ultrasound imaging: assessment of tissue viscoelasticity. Ultrafast image formation can be utilized to find transitory shear waves propagating in soft tissue, which permits quantification of the mechanical properties of the tissue via elastography. This technique permits simple and noninvasive diagnosis and monitoring of disease. METHODS: This article presents a method to estimate the viscoelastic properties and rigidity of structures using the ultrasound technique known as shear wave elasticity imaging (SWEI). The Verasonics Vantage 128 research platform and L11-4v transducer were used to acquire radio frequency signals from a model 049A elastography phantom (CIRS, USA), with subsequent processing and analysis in MATLAB. RESULTS: The images and indexes obtained reflect the qualitative measurements of the different regions of inclusions in the phantom and the respective alterations in the viscoelastic properties of distinct areas. Comparison of the results obtained with this proposed technique and other commonly used techniques demonstrates the characteristics of median filtering in smoothing variations in velocity to form elastographic images. The results from the technique proposed in this study are within the margins of error indicated by the phantom manufacturer for each type of inclusion; for the phantom base and for type I, II, III, and IV inclusions, respectively, in kPa and percentage errors, these are 25 (24.0%), 8 (37.5%), 14 (28.6%), 45 (17.8%), and 80 (15.0%). The values obtained using the method proposed in this study and mean percentage errors were 29.18 (− 16.7%), 10.26 (− 28.2%), 15.64 (− 11.7%), 45.81 (− 1.8%), and 85.21 (− 6.5%), respectively. CONCLUSIONS: The new technique to obtain images uses a distinct filtering function which considers the mean velocity in the region around each pixel, in turn allowing adjustments according to the characteristics of the phantom inclusions within the ultrasound and optimizing the resulting elastographic images. BioMed Central 2019-03-12 /pmc/articles/PMC6417019/ /pubmed/30866955 http://dx.doi.org/10.1186/s12938-019-0641-6 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Carbente, Rubem P.
Maia, Joaquim M.
Assef, Amauri A.
Image reconstruction utilizing median filtering applied to elastography
title Image reconstruction utilizing median filtering applied to elastography
title_full Image reconstruction utilizing median filtering applied to elastography
title_fullStr Image reconstruction utilizing median filtering applied to elastography
title_full_unstemmed Image reconstruction utilizing median filtering applied to elastography
title_short Image reconstruction utilizing median filtering applied to elastography
title_sort image reconstruction utilizing median filtering applied to elastography
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6417019/
https://www.ncbi.nlm.nih.gov/pubmed/30866955
http://dx.doi.org/10.1186/s12938-019-0641-6
work_keys_str_mv AT carbenterubemp imagereconstructionutilizingmedianfilteringappliedtoelastography
AT maiajoaquimm imagereconstructionutilizingmedianfilteringappliedtoelastography
AT assefamauria imagereconstructionutilizingmedianfilteringappliedtoelastography