Cargando…

White blood cell count in birds: evaluation of a commercially available method

BACKGROUND: To conduct a hematological analysis of avian blood samples, standard automated cell counting is unreliable because all avian blood cells are nucleated. Therefore, quantitative white blood cell counting in birds is still performed manually, whereby the Natt-Herrick method is widely used i...

Descripción completa

Detalles Bibliográficos
Autores principales: Carisch, Lea, Stirn, Martina, Hatt, Jean Michel, Federer, Karin, Hofmann-Lehmann, Regina, Riond, Barbara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6417236/
https://www.ncbi.nlm.nih.gov/pubmed/30866927
http://dx.doi.org/10.1186/s12917-019-1834-8
_version_ 1783403527782006784
author Carisch, Lea
Stirn, Martina
Hatt, Jean Michel
Federer, Karin
Hofmann-Lehmann, Regina
Riond, Barbara
author_facet Carisch, Lea
Stirn, Martina
Hatt, Jean Michel
Federer, Karin
Hofmann-Lehmann, Regina
Riond, Barbara
author_sort Carisch, Lea
collection PubMed
description BACKGROUND: To conduct a hematological analysis of avian blood samples, standard automated cell counting is unreliable because all avian blood cells are nucleated. Therefore, quantitative white blood cell counting in birds is still performed manually, whereby the Natt-Herrick method is widely used in veterinary laboratories. The aim of this study was to evaluate a new commercially available single test system for avian white blood cell counting, the Natt-Herricks-Tic®, which would allow easy in-house analysis by clinicians or technicians. A total of 40 avian ethylenediaminetetraacetic acid (EDTA) blood samples from 24 different species were included in the study. To assess method agreement, each blood sample was analyzed for total white blood cell count with the test method and the Natt-Herrick reference method. To determine the imprecision of the reference method and the Natt-Herricks-Tic® method, the noncorrected white blood cell count was determined ten consecutive times from one avian EDTA blood sample for each method. RESULTS: The Natt-Herricks-Tic® method performed well concerning staining quality and countability of the granulocytes by the hemocytometer. In the agreement study, the Natt-Herricks-Tic® method showed a small proportional systematic error with a small positive mean bias of 282 white blood cells/μL but had wide 95% limits of agreement (− 4683 cells/μL to 5227 cells/μL), indicating random error. The precision study resulted in a coefficient of variation of 16% for the Natt-Herricks-Tic® method (the mean ± standard deviation: 9.7 ×  10(3)/μL ± 1.5 × 10(3)/μL) and 23% (the mean ± standard deviation: 7.9 × 10(3)/μL ± 1.8 × 10(3)/μL) for the reference method. CONCLUSIONS: The Natt-Herricks-Tic® method showed acceptable precision for a manual method and demonstrated good agreement with the reference method. It can be recommended as a reliable and suitable method for determining white blood cell counts in avian EDTA blood if nonstatistical quality control measures are used in the daily routine. The application of individual reference intervals for the interpretation of white blood cell counts in birds may improve the diagnostic performance of this important analyte in a clinical setting.
format Online
Article
Text
id pubmed-6417236
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-64172362019-03-25 White blood cell count in birds: evaluation of a commercially available method Carisch, Lea Stirn, Martina Hatt, Jean Michel Federer, Karin Hofmann-Lehmann, Regina Riond, Barbara BMC Vet Res Research Article BACKGROUND: To conduct a hematological analysis of avian blood samples, standard automated cell counting is unreliable because all avian blood cells are nucleated. Therefore, quantitative white blood cell counting in birds is still performed manually, whereby the Natt-Herrick method is widely used in veterinary laboratories. The aim of this study was to evaluate a new commercially available single test system for avian white blood cell counting, the Natt-Herricks-Tic®, which would allow easy in-house analysis by clinicians or technicians. A total of 40 avian ethylenediaminetetraacetic acid (EDTA) blood samples from 24 different species were included in the study. To assess method agreement, each blood sample was analyzed for total white blood cell count with the test method and the Natt-Herrick reference method. To determine the imprecision of the reference method and the Natt-Herricks-Tic® method, the noncorrected white blood cell count was determined ten consecutive times from one avian EDTA blood sample for each method. RESULTS: The Natt-Herricks-Tic® method performed well concerning staining quality and countability of the granulocytes by the hemocytometer. In the agreement study, the Natt-Herricks-Tic® method showed a small proportional systematic error with a small positive mean bias of 282 white blood cells/μL but had wide 95% limits of agreement (− 4683 cells/μL to 5227 cells/μL), indicating random error. The precision study resulted in a coefficient of variation of 16% for the Natt-Herricks-Tic® method (the mean ± standard deviation: 9.7 ×  10(3)/μL ± 1.5 × 10(3)/μL) and 23% (the mean ± standard deviation: 7.9 × 10(3)/μL ± 1.8 × 10(3)/μL) for the reference method. CONCLUSIONS: The Natt-Herricks-Tic® method showed acceptable precision for a manual method and demonstrated good agreement with the reference method. It can be recommended as a reliable and suitable method for determining white blood cell counts in avian EDTA blood if nonstatistical quality control measures are used in the daily routine. The application of individual reference intervals for the interpretation of white blood cell counts in birds may improve the diagnostic performance of this important analyte in a clinical setting. BioMed Central 2019-03-14 /pmc/articles/PMC6417236/ /pubmed/30866927 http://dx.doi.org/10.1186/s12917-019-1834-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Carisch, Lea
Stirn, Martina
Hatt, Jean Michel
Federer, Karin
Hofmann-Lehmann, Regina
Riond, Barbara
White blood cell count in birds: evaluation of a commercially available method
title White blood cell count in birds: evaluation of a commercially available method
title_full White blood cell count in birds: evaluation of a commercially available method
title_fullStr White blood cell count in birds: evaluation of a commercially available method
title_full_unstemmed White blood cell count in birds: evaluation of a commercially available method
title_short White blood cell count in birds: evaluation of a commercially available method
title_sort white blood cell count in birds: evaluation of a commercially available method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6417236/
https://www.ncbi.nlm.nih.gov/pubmed/30866927
http://dx.doi.org/10.1186/s12917-019-1834-8
work_keys_str_mv AT carischlea whitebloodcellcountinbirdsevaluationofacommerciallyavailablemethod
AT stirnmartina whitebloodcellcountinbirdsevaluationofacommerciallyavailablemethod
AT hattjeanmichel whitebloodcellcountinbirdsevaluationofacommerciallyavailablemethod
AT federerkarin whitebloodcellcountinbirdsevaluationofacommerciallyavailablemethod
AT hofmannlehmannregina whitebloodcellcountinbirdsevaluationofacommerciallyavailablemethod
AT riondbarbara whitebloodcellcountinbirdsevaluationofacommerciallyavailablemethod