Cargando…

Fluoroscopic-Guided Paramedian Approach for Lumbar Catheter Placement in Cerebrospinal Fluid Shunting: Assessment of Safety and Accuracy

BACKGROUND: Spinal catheter insertion in lumboperitoneal (LP) shunt surgery for idiopathic normal pressure hydrocephalus (iNPH) is frequently associated with technical difficulties especially in patients with obesity and elderly patients with vertebral deformities. OBJECTIVE: To elucidate the accura...

Descripción completa

Detalles Bibliográficos
Autores principales: Tucker, Adam, Kajimoto, Yoshinaga, Ohmura, Tomohisa, Ikeda, Naokado, Furuse, Motomasa, Nonoguchi, Naosuke, Kawabata, Shinji, Kuroiwa, Toshihiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6417911/
https://www.ncbi.nlm.nih.gov/pubmed/30011016
http://dx.doi.org/10.1093/ons/opy176
Descripción
Sumario:BACKGROUND: Spinal catheter insertion in lumboperitoneal (LP) shunt surgery for idiopathic normal pressure hydrocephalus (iNPH) is frequently associated with technical difficulties especially in patients with obesity and elderly patients with vertebral deformities. OBJECTIVE: To elucidate the accuracy and safety of image-guided spinal catheter placement using a paramedian approach (PMA). METHODS: We retrospectively analyzed 39 consecutive iNPH patients treated by LP shunting with spinal catheter insertion via the PMA. The success rate of catheter placement and the number of changes in puncture location were evaluated. Accuracy of catheter insertion was assessed by measuring both vertical and horizontal deviations in the point of catheter dural penetration from the center of the interlaminar space. RESULTS: The success rate of catheter placement was 100% (39/39). The difficulty rate for catheter insertion, measured by the number of changes in puncture location, was 2.6% (1/39). No bloody punctures or surgical infections were observed. Accuracy of catheter insertion, measured as the degree of deviation, was 0.5 ± 1.9 mm horizontally and 0.0 ± 2.4 mm vertically. The rates of minor complications, including caudal catheter insertion, transient low-pressure headache, and root pain, were 5.1% (2/39), 10.4% (4/39), and 0% (0/43), respectively. Subdural hematoma requiring surgical intervention occurred in 1 case (2.6%). During the mean follow-up period of 36 mo, spinal catheter rupture at the level of the spinous processes was not observed. CONCLUSION: Fluoroscopic-guided spinal catheter placement via the PMA was safe, accurate, and reliable, even for use in geriatric and obese patients.