Cargando…
Effective high compression of ECG signals at low level distortion
An effective method for compression of ECG signals, which falls within the transform lossy compression category, is proposed. The transformation is realized by a fast wavelet transform. The effectiveness of the approach, in relation to the simplicity and speed of its implementation, is a consequence...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6418132/ https://www.ncbi.nlm.nih.gov/pubmed/30872627 http://dx.doi.org/10.1038/s41598-019-40350-x |
_version_ | 1783403669933260800 |
---|---|
author | Rebollo-Neira, Laura |
author_facet | Rebollo-Neira, Laura |
author_sort | Rebollo-Neira, Laura |
collection | PubMed |
description | An effective method for compression of ECG signals, which falls within the transform lossy compression category, is proposed. The transformation is realized by a fast wavelet transform. The effectiveness of the approach, in relation to the simplicity and speed of its implementation, is a consequence of the efficient storage of the outputs of the algorithm which is realized in compressed Hierarchical Data Format. The compression performance is tested on the MIT-BIH Arrhythmia database producing compression results which largely improve upon recently reported benchmarks on the same database. For a distortion corresponding to a percentage root-mean-square difference (PRD) of 0.53, in mean value, the achieved average compression ratio is 23.17 with quality score of 43.93. For a mean value of PRD up to 1.71 the compression ratio increases up to 62.5. The compression of a 30 min record is realized in an average time of 0.14 s. The insignificant delay for the compression process, together with the high compression ratio achieved at low level distortion and the negligible time for the signal recovery, uphold the suitability of the technique for supporting distant clinical health care. |
format | Online Article Text |
id | pubmed-6418132 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-64181322019-03-18 Effective high compression of ECG signals at low level distortion Rebollo-Neira, Laura Sci Rep Article An effective method for compression of ECG signals, which falls within the transform lossy compression category, is proposed. The transformation is realized by a fast wavelet transform. The effectiveness of the approach, in relation to the simplicity and speed of its implementation, is a consequence of the efficient storage of the outputs of the algorithm which is realized in compressed Hierarchical Data Format. The compression performance is tested on the MIT-BIH Arrhythmia database producing compression results which largely improve upon recently reported benchmarks on the same database. For a distortion corresponding to a percentage root-mean-square difference (PRD) of 0.53, in mean value, the achieved average compression ratio is 23.17 with quality score of 43.93. For a mean value of PRD up to 1.71 the compression ratio increases up to 62.5. The compression of a 30 min record is realized in an average time of 0.14 s. The insignificant delay for the compression process, together with the high compression ratio achieved at low level distortion and the negligible time for the signal recovery, uphold the suitability of the technique for supporting distant clinical health care. Nature Publishing Group UK 2019-03-14 /pmc/articles/PMC6418132/ /pubmed/30872627 http://dx.doi.org/10.1038/s41598-019-40350-x Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Rebollo-Neira, Laura Effective high compression of ECG signals at low level distortion |
title | Effective high compression of ECG signals at low level distortion |
title_full | Effective high compression of ECG signals at low level distortion |
title_fullStr | Effective high compression of ECG signals at low level distortion |
title_full_unstemmed | Effective high compression of ECG signals at low level distortion |
title_short | Effective high compression of ECG signals at low level distortion |
title_sort | effective high compression of ecg signals at low level distortion |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6418132/ https://www.ncbi.nlm.nih.gov/pubmed/30872627 http://dx.doi.org/10.1038/s41598-019-40350-x |
work_keys_str_mv | AT rebolloneiralaura effectivehighcompressionofecgsignalsatlowleveldistortion |