Cargando…
Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil
The rapid spread of Zika virus (ZIKV) represents a global public health problem, especially in areas that harbor several mosquito species responsible for virus transmission, such as Brazil. In these areas, improvement in mosquito control needs to be a top priority, but mosquito viral surveillance oc...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6418238/ https://www.ncbi.nlm.nih.gov/pubmed/30872672 http://dx.doi.org/10.1038/s41598-019-40960-5 |
_version_ | 1783403694891466752 |
---|---|
author | Silva, Severino Jefferson Ribeiro da Paiva, Marcelo Henrique Santos Guedes, Duschinka Ribeiro Duarte Krokovsky, Larissa Melo, Fábio Lopes de Silva, Maria Almerice Lopes da Silva, Adalúcia da Ayres, Constância Flávia Junqueira Pena, Lindomar J. |
author_facet | Silva, Severino Jefferson Ribeiro da Paiva, Marcelo Henrique Santos Guedes, Duschinka Ribeiro Duarte Krokovsky, Larissa Melo, Fábio Lopes de Silva, Maria Almerice Lopes da Silva, Adalúcia da Ayres, Constância Flávia Junqueira Pena, Lindomar J. |
author_sort | Silva, Severino Jefferson Ribeiro da |
collection | PubMed |
description | The rapid spread of Zika virus (ZIKV) represents a global public health problem, especially in areas that harbor several mosquito species responsible for virus transmission, such as Brazil. In these areas, improvement in mosquito control needs to be a top priority, but mosquito viral surveillance occurs inefficiently in ZIKV-endemic countries. Quantitative reverse transcription PCR (qRT-PCR) is the gold standard for molecular diagnostic of ZIKV in both human and mosquito samples. However, the technique presents high cost and limitations for Point-of-care (POC) diagnostics, which hampers its application for a large number of samples in entomological surveillance programs. Here, we developed and validated a one-step reverse transcription LAMP (RT-LAMP) platform for detection of ZIKV in mosquito samples. The RT-LAMP assay was highly specific for ZIKV and up to 10,000 times more sensitive than qRT-PCR. Assay validation was performed using 60 samples from Aedes aegypti and Culex quinquefasciatus mosquitoes collected in Pernambuco State, Brazil, which is at the epicenter of the Zika epidemic. The RT-LAMP had a sensitivity of 100%, specificity of 91.18%, and overall accuracy of 95.24%. Thus, our POC diagnostics is a powerful and inexpensive tool to monitor ZIKV in mosquito populations and will allow developing countries to establish better control strategies for this devastating pathogen. |
format | Online Article Text |
id | pubmed-6418238 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-64182382019-03-18 Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil Silva, Severino Jefferson Ribeiro da Paiva, Marcelo Henrique Santos Guedes, Duschinka Ribeiro Duarte Krokovsky, Larissa Melo, Fábio Lopes de Silva, Maria Almerice Lopes da Silva, Adalúcia da Ayres, Constância Flávia Junqueira Pena, Lindomar J. Sci Rep Article The rapid spread of Zika virus (ZIKV) represents a global public health problem, especially in areas that harbor several mosquito species responsible for virus transmission, such as Brazil. In these areas, improvement in mosquito control needs to be a top priority, but mosquito viral surveillance occurs inefficiently in ZIKV-endemic countries. Quantitative reverse transcription PCR (qRT-PCR) is the gold standard for molecular diagnostic of ZIKV in both human and mosquito samples. However, the technique presents high cost and limitations for Point-of-care (POC) diagnostics, which hampers its application for a large number of samples in entomological surveillance programs. Here, we developed and validated a one-step reverse transcription LAMP (RT-LAMP) platform for detection of ZIKV in mosquito samples. The RT-LAMP assay was highly specific for ZIKV and up to 10,000 times more sensitive than qRT-PCR. Assay validation was performed using 60 samples from Aedes aegypti and Culex quinquefasciatus mosquitoes collected in Pernambuco State, Brazil, which is at the epicenter of the Zika epidemic. The RT-LAMP had a sensitivity of 100%, specificity of 91.18%, and overall accuracy of 95.24%. Thus, our POC diagnostics is a powerful and inexpensive tool to monitor ZIKV in mosquito populations and will allow developing countries to establish better control strategies for this devastating pathogen. Nature Publishing Group UK 2019-03-14 /pmc/articles/PMC6418238/ /pubmed/30872672 http://dx.doi.org/10.1038/s41598-019-40960-5 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Silva, Severino Jefferson Ribeiro da Paiva, Marcelo Henrique Santos Guedes, Duschinka Ribeiro Duarte Krokovsky, Larissa Melo, Fábio Lopes de Silva, Maria Almerice Lopes da Silva, Adalúcia da Ayres, Constância Flávia Junqueira Pena, Lindomar J. Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil |
title | Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil |
title_full | Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil |
title_fullStr | Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil |
title_full_unstemmed | Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil |
title_short | Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil |
title_sort | development and validation of reverse transcription loop-mediated isothermal amplification (rt-lamp) for rapid detection of zikv in mosquito samples from brazil |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6418238/ https://www.ncbi.nlm.nih.gov/pubmed/30872672 http://dx.doi.org/10.1038/s41598-019-40960-5 |
work_keys_str_mv | AT silvaseverinojeffersonribeiroda developmentandvalidationofreversetranscriptionloopmediatedisothermalamplificationrtlampforrapiddetectionofzikvinmosquitosamplesfrombrazil AT paivamarcelohenriquesantos developmentandvalidationofreversetranscriptionloopmediatedisothermalamplificationrtlampforrapiddetectionofzikvinmosquitosamplesfrombrazil AT guedesduschinkaribeiroduarte developmentandvalidationofreversetranscriptionloopmediatedisothermalamplificationrtlampforrapiddetectionofzikvinmosquitosamplesfrombrazil AT krokovskylarissa developmentandvalidationofreversetranscriptionloopmediatedisothermalamplificationrtlampforrapiddetectionofzikvinmosquitosamplesfrombrazil AT melofabiolopesde developmentandvalidationofreversetranscriptionloopmediatedisothermalamplificationrtlampforrapiddetectionofzikvinmosquitosamplesfrombrazil AT silvamariaalmericelopesda developmentandvalidationofreversetranscriptionloopmediatedisothermalamplificationrtlampforrapiddetectionofzikvinmosquitosamplesfrombrazil AT silvaadaluciada developmentandvalidationofreversetranscriptionloopmediatedisothermalamplificationrtlampforrapiddetectionofzikvinmosquitosamplesfrombrazil AT ayresconstanciaflaviajunqueira developmentandvalidationofreversetranscriptionloopmediatedisothermalamplificationrtlampforrapiddetectionofzikvinmosquitosamplesfrombrazil AT penalindomarj developmentandvalidationofreversetranscriptionloopmediatedisothermalamplificationrtlampforrapiddetectionofzikvinmosquitosamplesfrombrazil |