Cargando…
Correlation-Based Multiplexing of Complex Amplitude Data Pages in a Holographic Storage System Using Digital Holographic Techniques
Holographic recording media can store the amplitude and the phase, or the complex amplitude, of a beam on the basis of holography. Owing to this characteristic, digital data can be encoded onto the complex amplitude of a signal beam in holographic data storage. However, most of conventional holograp...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6418671/ https://www.ncbi.nlm.nih.gov/pubmed/30971047 http://dx.doi.org/10.3390/polym9080375 |
_version_ | 1783403784209170432 |
---|---|
author | Nobukawa, Teruyoshi Nomura, Takanori |
author_facet | Nobukawa, Teruyoshi Nomura, Takanori |
author_sort | Nobukawa, Teruyoshi |
collection | PubMed |
description | Holographic recording media can store the amplitude and the phase, or the complex amplitude, of a beam on the basis of holography. Owing to this characteristic, digital data can be encoded onto the complex amplitude of a signal beam in holographic data storage. However, most of conventional holographic storage systems encode digital data onto the amplitude alone because there are difficulties for modulating and detecting the phase. To solve the difficulties, a holographic storage system using digital holographic techniques has been proposed. With the help of digital holographic techniques, it is possible to modulate and detect the complex amplitude of a signal beam. Moreover, the proposed system can modulate the complex amplitude of a reference beam. In this paper, by making use of the capability, a correlation-based multiplexing with uncorrelated reference beams is demonstrated in the proposed system. Multiple holograms can be recorded in the same volume of a recording medium with no need for mechanical movements. Experimental results show that the proposed system with a correlation-based multiplexing can improve the storage capacity and can utilize the full potential of a recording medium without crosstalk noise stem from the optical setup. |
format | Online Article Text |
id | pubmed-6418671 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64186712019-04-02 Correlation-Based Multiplexing of Complex Amplitude Data Pages in a Holographic Storage System Using Digital Holographic Techniques Nobukawa, Teruyoshi Nomura, Takanori Polymers (Basel) Article Holographic recording media can store the amplitude and the phase, or the complex amplitude, of a beam on the basis of holography. Owing to this characteristic, digital data can be encoded onto the complex amplitude of a signal beam in holographic data storage. However, most of conventional holographic storage systems encode digital data onto the amplitude alone because there are difficulties for modulating and detecting the phase. To solve the difficulties, a holographic storage system using digital holographic techniques has been proposed. With the help of digital holographic techniques, it is possible to modulate and detect the complex amplitude of a signal beam. Moreover, the proposed system can modulate the complex amplitude of a reference beam. In this paper, by making use of the capability, a correlation-based multiplexing with uncorrelated reference beams is demonstrated in the proposed system. Multiple holograms can be recorded in the same volume of a recording medium with no need for mechanical movements. Experimental results show that the proposed system with a correlation-based multiplexing can improve the storage capacity and can utilize the full potential of a recording medium without crosstalk noise stem from the optical setup. MDPI 2017-08-18 /pmc/articles/PMC6418671/ /pubmed/30971047 http://dx.doi.org/10.3390/polym9080375 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Nobukawa, Teruyoshi Nomura, Takanori Correlation-Based Multiplexing of Complex Amplitude Data Pages in a Holographic Storage System Using Digital Holographic Techniques |
title | Correlation-Based Multiplexing of Complex Amplitude Data Pages in a Holographic Storage System Using Digital Holographic Techniques |
title_full | Correlation-Based Multiplexing of Complex Amplitude Data Pages in a Holographic Storage System Using Digital Holographic Techniques |
title_fullStr | Correlation-Based Multiplexing of Complex Amplitude Data Pages in a Holographic Storage System Using Digital Holographic Techniques |
title_full_unstemmed | Correlation-Based Multiplexing of Complex Amplitude Data Pages in a Holographic Storage System Using Digital Holographic Techniques |
title_short | Correlation-Based Multiplexing of Complex Amplitude Data Pages in a Holographic Storage System Using Digital Holographic Techniques |
title_sort | correlation-based multiplexing of complex amplitude data pages in a holographic storage system using digital holographic techniques |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6418671/ https://www.ncbi.nlm.nih.gov/pubmed/30971047 http://dx.doi.org/10.3390/polym9080375 |
work_keys_str_mv | AT nobukawateruyoshi correlationbasedmultiplexingofcomplexamplitudedatapagesinaholographicstoragesystemusingdigitalholographictechniques AT nomuratakanori correlationbasedmultiplexingofcomplexamplitudedatapagesinaholographicstoragesystemusingdigitalholographictechniques |