Cargando…

Comparison between pulse wave velocities measured using Complior and measured using Biopac

Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoele...

Descripción completa

Detalles Bibliográficos
Autores principales: van Velzen, Marit H. N., Stolker, Robert Jan, Loeve, Arjo J., Niehof, Sjoerd P., Mik, Egbert G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6420418/
https://www.ncbi.nlm.nih.gov/pubmed/29876710
http://dx.doi.org/10.1007/s10877-018-0165-9
_version_ 1783404078205763584
author van Velzen, Marit H. N.
Stolker, Robert Jan
Loeve, Arjo J.
Niehof, Sjoerd P.
Mik, Egbert G.
author_facet van Velzen, Marit H. N.
Stolker, Robert Jan
Loeve, Arjo J.
Niehof, Sjoerd P.
Mik, Egbert G.
author_sort van Velzen, Marit H. N.
collection PubMed
description Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed around the neck and the wrist. The Biopac system is an easier to use alternative that uses ECG and simple optical sensors to measure the PWV between the heart and the fingertips, and thus extends a bit more to the peripheral vasculature compared to the Complior system. The goal of this study was to test under various conditions to what extent these systems provide comparable and correlating values. 25 Healthy volunteers, 20–30 years old, were measured in four sequential position: sitting, lying, standing and sitting. The results showed that the Biopac system measured consistently and significantly lower PWV values than the Complior system, for all positions. Correlation values and Bland–Altman plots showed that despite the difference in PWV magnitudes obtained by the two systems the measurements did agree well. Which implies that as long as the differences in PWV magnitudes are taken into account, either system could be used to measure PWV changes over time. However, when basing diagnosis on absolute PWV values, one should be very much aware of how the PWV was measured and with what system.
format Online
Article
Text
id pubmed-6420418
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-64204182019-04-03 Comparison between pulse wave velocities measured using Complior and measured using Biopac van Velzen, Marit H. N. Stolker, Robert Jan Loeve, Arjo J. Niehof, Sjoerd P. Mik, Egbert G. J Clin Monit Comput Original Research Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed around the neck and the wrist. The Biopac system is an easier to use alternative that uses ECG and simple optical sensors to measure the PWV between the heart and the fingertips, and thus extends a bit more to the peripheral vasculature compared to the Complior system. The goal of this study was to test under various conditions to what extent these systems provide comparable and correlating values. 25 Healthy volunteers, 20–30 years old, were measured in four sequential position: sitting, lying, standing and sitting. The results showed that the Biopac system measured consistently and significantly lower PWV values than the Complior system, for all positions. Correlation values and Bland–Altman plots showed that despite the difference in PWV magnitudes obtained by the two systems the measurements did agree well. Which implies that as long as the differences in PWV magnitudes are taken into account, either system could be used to measure PWV changes over time. However, when basing diagnosis on absolute PWV values, one should be very much aware of how the PWV was measured and with what system. Springer Netherlands 2018-06-06 2019 /pmc/articles/PMC6420418/ /pubmed/29876710 http://dx.doi.org/10.1007/s10877-018-0165-9 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
van Velzen, Marit H. N.
Stolker, Robert Jan
Loeve, Arjo J.
Niehof, Sjoerd P.
Mik, Egbert G.
Comparison between pulse wave velocities measured using Complior and measured using Biopac
title Comparison between pulse wave velocities measured using Complior and measured using Biopac
title_full Comparison between pulse wave velocities measured using Complior and measured using Biopac
title_fullStr Comparison between pulse wave velocities measured using Complior and measured using Biopac
title_full_unstemmed Comparison between pulse wave velocities measured using Complior and measured using Biopac
title_short Comparison between pulse wave velocities measured using Complior and measured using Biopac
title_sort comparison between pulse wave velocities measured using complior and measured using biopac
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6420418/
https://www.ncbi.nlm.nih.gov/pubmed/29876710
http://dx.doi.org/10.1007/s10877-018-0165-9
work_keys_str_mv AT vanvelzenmarithn comparisonbetweenpulsewavevelocitiesmeasuredusingcompliorandmeasuredusingbiopac
AT stolkerrobertjan comparisonbetweenpulsewavevelocitiesmeasuredusingcompliorandmeasuredusingbiopac
AT loevearjoj comparisonbetweenpulsewavevelocitiesmeasuredusingcompliorandmeasuredusingbiopac
AT niehofsjoerdp comparisonbetweenpulsewavevelocitiesmeasuredusingcompliorandmeasuredusingbiopac
AT mikegbertg comparisonbetweenpulsewavevelocitiesmeasuredusingcompliorandmeasuredusingbiopac