Cargando…
Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report
BACKGROUND: Distally fixed cylindrical femoral stems extensively coated with porous materials are widely used in revision and total hip arthroplasty surgeries. Stem fracture is an uncommon complication; few case reports have been published. CASE PRESENTATION: We report the case of a 51-year-old male...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6421697/ https://www.ncbi.nlm.nih.gov/pubmed/30885178 http://dx.doi.org/10.1186/s12891-019-2489-0 |
_version_ | 1783404276941324288 |
---|---|
author | Zhu, Leibo He, Rongxin |
author_facet | Zhu, Leibo He, Rongxin |
author_sort | Zhu, Leibo |
collection | PubMed |
description | BACKGROUND: Distally fixed cylindrical femoral stems extensively coated with porous materials are widely used in revision and total hip arthroplasty surgeries. Stem fracture is an uncommon complication; few case reports have been published. CASE PRESENTATION: We report the case of a 51-year-old male exhibiting extensively porous-coated cylindrical femoral stems fracture after staged bilateral hip revision. His body mass index was 24.22 kg/m(2). The major risk factor was poor proximal bony support; and femoral stems with smaller diameter. CONCLUSIONS: Certain patients are at high risk of non-contemporaneous, bilateral femoral stem fractures. It remains unclear whether fracture of the contralateral femoral stem is an inevitable fatigue fracture or reflects the increased weight imposed on the contralateral hip after the first revision. We recommend that a strut bone graft be placed to support the proximal bone, and that non-modular tapered femoral stems be employed in such patients. |
format | Online Article Text |
id | pubmed-6421697 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-64216972019-03-28 Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report Zhu, Leibo He, Rongxin BMC Musculoskelet Disord Case Report BACKGROUND: Distally fixed cylindrical femoral stems extensively coated with porous materials are widely used in revision and total hip arthroplasty surgeries. Stem fracture is an uncommon complication; few case reports have been published. CASE PRESENTATION: We report the case of a 51-year-old male exhibiting extensively porous-coated cylindrical femoral stems fracture after staged bilateral hip revision. His body mass index was 24.22 kg/m(2). The major risk factor was poor proximal bony support; and femoral stems with smaller diameter. CONCLUSIONS: Certain patients are at high risk of non-contemporaneous, bilateral femoral stem fractures. It remains unclear whether fracture of the contralateral femoral stem is an inevitable fatigue fracture or reflects the increased weight imposed on the contralateral hip after the first revision. We recommend that a strut bone graft be placed to support the proximal bone, and that non-modular tapered femoral stems be employed in such patients. BioMed Central 2019-03-18 /pmc/articles/PMC6421697/ /pubmed/30885178 http://dx.doi.org/10.1186/s12891-019-2489-0 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Case Report Zhu, Leibo He, Rongxin Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report |
title | Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report |
title_full | Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report |
title_fullStr | Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report |
title_full_unstemmed | Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report |
title_short | Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report |
title_sort | non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6421697/ https://www.ncbi.nlm.nih.gov/pubmed/30885178 http://dx.doi.org/10.1186/s12891-019-2489-0 |
work_keys_str_mv | AT zhuleibo noncontemporaneousbilateralstemfracturesoccurringafterstagedbilateralhiprevisionusingextensivelyporouscoatedcylindricalfemoralstemsacasereport AT herongxin noncontemporaneousbilateralstemfracturesoccurringafterstagedbilateralhiprevisionusingextensivelyporouscoatedcylindricalfemoralstemsacasereport |