Cargando…

Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report

BACKGROUND: Distally fixed cylindrical femoral stems extensively coated with porous materials are widely used in revision and total hip arthroplasty surgeries. Stem fracture is an uncommon complication; few case reports have been published. CASE PRESENTATION: We report the case of a 51-year-old male...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Leibo, He, Rongxin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6421697/
https://www.ncbi.nlm.nih.gov/pubmed/30885178
http://dx.doi.org/10.1186/s12891-019-2489-0
_version_ 1783404276941324288
author Zhu, Leibo
He, Rongxin
author_facet Zhu, Leibo
He, Rongxin
author_sort Zhu, Leibo
collection PubMed
description BACKGROUND: Distally fixed cylindrical femoral stems extensively coated with porous materials are widely used in revision and total hip arthroplasty surgeries. Stem fracture is an uncommon complication; few case reports have been published. CASE PRESENTATION: We report the case of a 51-year-old male exhibiting extensively porous-coated cylindrical femoral stems fracture after staged bilateral hip revision. His body mass index was 24.22 kg/m(2). The major risk factor was poor proximal bony support; and femoral stems with smaller diameter. CONCLUSIONS: Certain patients are at high risk of non-contemporaneous, bilateral femoral stem fractures. It remains unclear whether fracture of the contralateral femoral stem is an inevitable fatigue fracture or reflects the increased weight imposed on the contralateral hip after the first revision. We recommend that a strut bone graft be placed to support the proximal bone, and that non-modular tapered femoral stems be employed in such patients.
format Online
Article
Text
id pubmed-6421697
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-64216972019-03-28 Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report Zhu, Leibo He, Rongxin BMC Musculoskelet Disord Case Report BACKGROUND: Distally fixed cylindrical femoral stems extensively coated with porous materials are widely used in revision and total hip arthroplasty surgeries. Stem fracture is an uncommon complication; few case reports have been published. CASE PRESENTATION: We report the case of a 51-year-old male exhibiting extensively porous-coated cylindrical femoral stems fracture after staged bilateral hip revision. His body mass index was 24.22 kg/m(2). The major risk factor was poor proximal bony support; and femoral stems with smaller diameter. CONCLUSIONS: Certain patients are at high risk of non-contemporaneous, bilateral femoral stem fractures. It remains unclear whether fracture of the contralateral femoral stem is an inevitable fatigue fracture or reflects the increased weight imposed on the contralateral hip after the first revision. We recommend that a strut bone graft be placed to support the proximal bone, and that non-modular tapered femoral stems be employed in such patients. BioMed Central 2019-03-18 /pmc/articles/PMC6421697/ /pubmed/30885178 http://dx.doi.org/10.1186/s12891-019-2489-0 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Case Report
Zhu, Leibo
He, Rongxin
Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report
title Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report
title_full Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report
title_fullStr Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report
title_full_unstemmed Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report
title_short Non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report
title_sort non-contemporaneous bilateral stem fractures occurring after staged bilateral hip revision using extensively porous-coated cylindrical femoral stems: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6421697/
https://www.ncbi.nlm.nih.gov/pubmed/30885178
http://dx.doi.org/10.1186/s12891-019-2489-0
work_keys_str_mv AT zhuleibo noncontemporaneousbilateralstemfracturesoccurringafterstagedbilateralhiprevisionusingextensivelyporouscoatedcylindricalfemoralstemsacasereport
AT herongxin noncontemporaneousbilateralstemfracturesoccurringafterstagedbilateralhiprevisionusingextensivelyporouscoatedcylindricalfemoralstemsacasereport