Hemoperitoneum: a complication of loop electrosurgical excision procedure

Loop electrosurgical excision procedure (LEEP) is commonly performed for the management of cervical intraepithelial neoplasia. Although LEEP is considered to be a relatively simple procedure, several unexpected complications have been reported in the literature. Herein, we report a case of hemoperit...

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, Angela, Park, Sunwha, Park, Soyun, Kang, Hye Sim, Shim, Soon Sup, Park, Chul Min, Kim, Sung Yob
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology; Korean Urogynecologic Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6422840/
https://www.ncbi.nlm.nih.gov/pubmed/30918883
http://dx.doi.org/10.5468/ogs.2019.62.2.138
Descripción
Sumario:Loop electrosurgical excision procedure (LEEP) is commonly performed for the management of cervical intraepithelial neoplasia. Although LEEP is considered to be a relatively simple procedure, several unexpected complications have been reported in the literature. Herein, we report a case of hemoperitoneum caused by uterine perforation following LEEP. Blood collection in pelvic cavity and two small defects of the uterus were confirmed by diagnostic laparoscopy. The defects were sutured and the patient recovered well after the operation.