Cargando…
Hemoperitoneum: a complication of loop electrosurgical excision procedure
Loop electrosurgical excision procedure (LEEP) is commonly performed for the management of cervical intraepithelial neoplasia. Although LEEP is considered to be a relatively simple procedure, several unexpected complications have been reported in the literature. Herein, we report a case of hemoperit...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology; Korean Urogynecologic Society
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6422840/ https://www.ncbi.nlm.nih.gov/pubmed/30918883 http://dx.doi.org/10.5468/ogs.2019.62.2.138 |
_version_ | 1783404422060048384 |
---|---|
author | Cho, Angela Park, Sunwha Park, Soyun Kang, Hye Sim Shim, Soon Sup Park, Chul Min Kim, Sung Yob |
author_facet | Cho, Angela Park, Sunwha Park, Soyun Kang, Hye Sim Shim, Soon Sup Park, Chul Min Kim, Sung Yob |
author_sort | Cho, Angela |
collection | PubMed |
description | Loop electrosurgical excision procedure (LEEP) is commonly performed for the management of cervical intraepithelial neoplasia. Although LEEP is considered to be a relatively simple procedure, several unexpected complications have been reported in the literature. Herein, we report a case of hemoperitoneum caused by uterine perforation following LEEP. Blood collection in pelvic cavity and two small defects of the uterus were confirmed by diagnostic laparoscopy. The defects were sutured and the patient recovered well after the operation. |
format | Online Article Text |
id | pubmed-6422840 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology; Korean Urogynecologic Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-64228402019-03-27 Hemoperitoneum: a complication of loop electrosurgical excision procedure Cho, Angela Park, Sunwha Park, Soyun Kang, Hye Sim Shim, Soon Sup Park, Chul Min Kim, Sung Yob Obstet Gynecol Sci Case Report Loop electrosurgical excision procedure (LEEP) is commonly performed for the management of cervical intraepithelial neoplasia. Although LEEP is considered to be a relatively simple procedure, several unexpected complications have been reported in the literature. Herein, we report a case of hemoperitoneum caused by uterine perforation following LEEP. Blood collection in pelvic cavity and two small defects of the uterus were confirmed by diagnostic laparoscopy. The defects were sutured and the patient recovered well after the operation. Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology; Korean Urogynecologic Society 2019-03 2019-02-11 /pmc/articles/PMC6422840/ /pubmed/30918883 http://dx.doi.org/10.5468/ogs.2019.62.2.138 Text en Copyright © 2019 Korean Society of Obstetrics and Gynecology http://creativecommons.org/licenses/by-nc/3.0/ Articles published in Obstet Gynecol Sci are open-access, distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Cho, Angela Park, Sunwha Park, Soyun Kang, Hye Sim Shim, Soon Sup Park, Chul Min Kim, Sung Yob Hemoperitoneum: a complication of loop electrosurgical excision procedure |
title | Hemoperitoneum: a complication of loop electrosurgical excision procedure |
title_full | Hemoperitoneum: a complication of loop electrosurgical excision procedure |
title_fullStr | Hemoperitoneum: a complication of loop electrosurgical excision procedure |
title_full_unstemmed | Hemoperitoneum: a complication of loop electrosurgical excision procedure |
title_short | Hemoperitoneum: a complication of loop electrosurgical excision procedure |
title_sort | hemoperitoneum: a complication of loop electrosurgical excision procedure |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6422840/ https://www.ncbi.nlm.nih.gov/pubmed/30918883 http://dx.doi.org/10.5468/ogs.2019.62.2.138 |
work_keys_str_mv | AT choangela hemoperitoneumacomplicationofloopelectrosurgicalexcisionprocedure AT parksunwha hemoperitoneumacomplicationofloopelectrosurgicalexcisionprocedure AT parksoyun hemoperitoneumacomplicationofloopelectrosurgicalexcisionprocedure AT kanghyesim hemoperitoneumacomplicationofloopelectrosurgicalexcisionprocedure AT shimsoonsup hemoperitoneumacomplicationofloopelectrosurgicalexcisionprocedure AT parkchulmin hemoperitoneumacomplicationofloopelectrosurgicalexcisionprocedure AT kimsungyob hemoperitoneumacomplicationofloopelectrosurgicalexcisionprocedure |