Cargando…

Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia

Studies over the past decade have reported that the use of highly porous sockets in total hip arthroplasty (THA) results in osseointegration and long-term implant stability. However, some reports have raised concerns regarding radiographic evidence of poor osseointegration with features of fibrous t...

Descripción completa

Detalles Bibliográficos
Autores principales: Imai, Hiroshi, Miyawaki, Joji, Kamada, Tomomi, Maruishi, Akira, Takeba, Jun, Miura, Hiromasa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Paris 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6422951/
https://www.ncbi.nlm.nih.gov/pubmed/30488136
http://dx.doi.org/10.1007/s00590-018-2351-3
_version_ 1783404447824609280
author Imai, Hiroshi
Miyawaki, Joji
Kamada, Tomomi
Maruishi, Akira
Takeba, Jun
Miura, Hiromasa
author_facet Imai, Hiroshi
Miyawaki, Joji
Kamada, Tomomi
Maruishi, Akira
Takeba, Jun
Miura, Hiromasa
author_sort Imai, Hiroshi
collection PubMed
description Studies over the past decade have reported that the use of highly porous sockets in total hip arthroplasty (THA) results in osseointegration and long-term implant stability. However, some reports have raised concerns regarding radiographic evidence of poor osseointegration with features of fibrous tissue ingrowth. The purpose of this study was to compare clinical and radiographic assessments of highly porous sockets with those of hydroxyapatite (HA)-coated porous sockets in THA for hip dysplasia (DDH) at least 1 year after surgery. A total of 127 patients (136 hips) were recruited for the study. Of these, 94 patients (101 hips) received highly porous sockets with clustered screws, while 33 patients (35 hips) received HA-coated porous sockets with clustered screws. There was no difference in clinical outcomes between the two types of sockets. All HA-coated porous sockets were radiographically stable, without radiolucent lines. Fifteen hips had radiolucent lines in two or three DeLee and Charnley zones, accompanied by sclerotic lines along the circumferences of the highly porous sockets. A significant difference in the height of the preoperative osteophyte of the anterior acetabular wall was observed between 86 hips with one or no radiolucent lines and 15 hips with two or three radiolucent lines. In cases of DDH with atrophic bone remodeling pattern, highly porous sockets with multiple screws may be used, while HA-coated porous sockets with clustered screws result in better sealing of the bone–component interface.
format Online
Article
Text
id pubmed-6422951
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Paris
record_format MEDLINE/PubMed
spelling pubmed-64229512019-04-05 Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia Imai, Hiroshi Miyawaki, Joji Kamada, Tomomi Maruishi, Akira Takeba, Jun Miura, Hiromasa Eur J Orthop Surg Traumatol Original Article • HIP - ARTHROPLASTY Studies over the past decade have reported that the use of highly porous sockets in total hip arthroplasty (THA) results in osseointegration and long-term implant stability. However, some reports have raised concerns regarding radiographic evidence of poor osseointegration with features of fibrous tissue ingrowth. The purpose of this study was to compare clinical and radiographic assessments of highly porous sockets with those of hydroxyapatite (HA)-coated porous sockets in THA for hip dysplasia (DDH) at least 1 year after surgery. A total of 127 patients (136 hips) were recruited for the study. Of these, 94 patients (101 hips) received highly porous sockets with clustered screws, while 33 patients (35 hips) received HA-coated porous sockets with clustered screws. There was no difference in clinical outcomes between the two types of sockets. All HA-coated porous sockets were radiographically stable, without radiolucent lines. Fifteen hips had radiolucent lines in two or three DeLee and Charnley zones, accompanied by sclerotic lines along the circumferences of the highly porous sockets. A significant difference in the height of the preoperative osteophyte of the anterior acetabular wall was observed between 86 hips with one or no radiolucent lines and 15 hips with two or three radiolucent lines. In cases of DDH with atrophic bone remodeling pattern, highly porous sockets with multiple screws may be used, while HA-coated porous sockets with clustered screws result in better sealing of the bone–component interface. Springer Paris 2018-11-28 2019 /pmc/articles/PMC6422951/ /pubmed/30488136 http://dx.doi.org/10.1007/s00590-018-2351-3 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article • HIP - ARTHROPLASTY
Imai, Hiroshi
Miyawaki, Joji
Kamada, Tomomi
Maruishi, Akira
Takeba, Jun
Miura, Hiromasa
Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia
title Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia
title_full Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia
title_fullStr Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia
title_full_unstemmed Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia
title_short Radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia
title_sort radiolucency around highly porous sockets and hydroxyapatite-coated porous sockets in total hip arthroplasty for hip dysplasia
topic Original Article • HIP - ARTHROPLASTY
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6422951/
https://www.ncbi.nlm.nih.gov/pubmed/30488136
http://dx.doi.org/10.1007/s00590-018-2351-3
work_keys_str_mv AT imaihiroshi radiolucencyaroundhighlyporoussocketsandhydroxyapatitecoatedporoussocketsintotalhiparthroplastyforhipdysplasia
AT miyawakijoji radiolucencyaroundhighlyporoussocketsandhydroxyapatitecoatedporoussocketsintotalhiparthroplastyforhipdysplasia
AT kamadatomomi radiolucencyaroundhighlyporoussocketsandhydroxyapatitecoatedporoussocketsintotalhiparthroplastyforhipdysplasia
AT maruishiakira radiolucencyaroundhighlyporoussocketsandhydroxyapatitecoatedporoussocketsintotalhiparthroplastyforhipdysplasia
AT takebajun radiolucencyaroundhighlyporoussocketsandhydroxyapatitecoatedporoussocketsintotalhiparthroplastyforhipdysplasia
AT miurahiromasa radiolucencyaroundhighlyporoussocketsandhydroxyapatitecoatedporoussocketsintotalhiparthroplastyforhipdysplasia