Cargando…

Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method

OBJECTIVE: To evaluate whether computed tomography (CT) reconstruction algorithms affect the CT texture features of the liver parenchyma. MATERIALS AND METHODS: This retrospective study comprised 58 patients (normal liver, n = 34; chronic liver disease [CLD], n = 24) who underwent liver CT scans usi...

Descripción completa

Detalles Bibliográficos
Autores principales: Sung, Pamela, Lee, Jeong Min, Joo, Ijin, Lee, Sanghyup, Kim, Tae-Hyung, Ganeshan, Balaji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6424830/
https://www.ncbi.nlm.nih.gov/pubmed/30887738
http://dx.doi.org/10.3348/kjr.2018.0368
_version_ 1783404722985631744
author Sung, Pamela
Lee, Jeong Min
Joo, Ijin
Lee, Sanghyup
Kim, Tae-Hyung
Ganeshan, Balaji
author_facet Sung, Pamela
Lee, Jeong Min
Joo, Ijin
Lee, Sanghyup
Kim, Tae-Hyung
Ganeshan, Balaji
author_sort Sung, Pamela
collection PubMed
description OBJECTIVE: To evaluate whether computed tomography (CT) reconstruction algorithms affect the CT texture features of the liver parenchyma. MATERIALS AND METHODS: This retrospective study comprised 58 patients (normal liver, n = 34; chronic liver disease [CLD], n = 24) who underwent liver CT scans using a single CT scanner. All CT images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR) (iDOSE(4)), and model-based IR (IMR). On arterial phase (AP) and portal venous phase (PVP) CT imaging, quantitative texture analysis of the liver parenchyma using a single-slice region of interest was performed at the level of the hepatic hilum using a filtration-histogram statistic-based method with different filter values. Texture features were compared among the three reconstruction methods and between normal livers and those from CLD patients. Additionally, we evaluated the inter- and intra-observer reliability of the CT texture analysis by calculating intraclass correlation coefficients (ICCs). RESULTS: IR techniques affect various CT texture features of the liver parenchyma. In particular, model-based IR frequently showed significant differences compared to FBP or hybrid IR on both AP and PVP CT imaging. Significant variation in entropy was observed between the three reconstruction algorithms on PVP imaging (p < 0.05). Comparison between normal livers and those from CLD patients revealed that AP images depend more strongly on the reconstruction method used than PVP images. For both inter- and intra-observer reliability, ICCs were acceptable (> 0.75) for CT imaging without filtration. CONCLUSION: CT texture features of the liver parenchyma evaluated using the filtration-histogram method were significantly affected by the CT reconstruction algorithm used.
format Online
Article
Text
id pubmed-6424830
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-64248302019-04-01 Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method Sung, Pamela Lee, Jeong Min Joo, Ijin Lee, Sanghyup Kim, Tae-Hyung Ganeshan, Balaji Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To evaluate whether computed tomography (CT) reconstruction algorithms affect the CT texture features of the liver parenchyma. MATERIALS AND METHODS: This retrospective study comprised 58 patients (normal liver, n = 34; chronic liver disease [CLD], n = 24) who underwent liver CT scans using a single CT scanner. All CT images were reconstructed using filtered back projection (FBP), hybrid iterative reconstruction (IR) (iDOSE(4)), and model-based IR (IMR). On arterial phase (AP) and portal venous phase (PVP) CT imaging, quantitative texture analysis of the liver parenchyma using a single-slice region of interest was performed at the level of the hepatic hilum using a filtration-histogram statistic-based method with different filter values. Texture features were compared among the three reconstruction methods and between normal livers and those from CLD patients. Additionally, we evaluated the inter- and intra-observer reliability of the CT texture analysis by calculating intraclass correlation coefficients (ICCs). RESULTS: IR techniques affect various CT texture features of the liver parenchyma. In particular, model-based IR frequently showed significant differences compared to FBP or hybrid IR on both AP and PVP CT imaging. Significant variation in entropy was observed between the three reconstruction algorithms on PVP imaging (p < 0.05). Comparison between normal livers and those from CLD patients revealed that AP images depend more strongly on the reconstruction method used than PVP images. For both inter- and intra-observer reliability, ICCs were acceptable (> 0.75) for CT imaging without filtration. CONCLUSION: CT texture features of the liver parenchyma evaluated using the filtration-histogram method were significantly affected by the CT reconstruction algorithm used. The Korean Society of Radiology 2019-04 2019-02-25 /pmc/articles/PMC6424830/ /pubmed/30887738 http://dx.doi.org/10.3348/kjr.2018.0368 Text en Copyright © 2019 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Gastrointestinal Imaging
Sung, Pamela
Lee, Jeong Min
Joo, Ijin
Lee, Sanghyup
Kim, Tae-Hyung
Ganeshan, Balaji
Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method
title Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method
title_full Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method
title_fullStr Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method
title_full_unstemmed Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method
title_short Evaluation of the Impact of Iterative Reconstruction Algorithms on Computed Tomography Texture Features of the Liver Parenchyma Using the Filtration-Histogram Method
title_sort evaluation of the impact of iterative reconstruction algorithms on computed tomography texture features of the liver parenchyma using the filtration-histogram method
topic Gastrointestinal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6424830/
https://www.ncbi.nlm.nih.gov/pubmed/30887738
http://dx.doi.org/10.3348/kjr.2018.0368
work_keys_str_mv AT sungpamela evaluationoftheimpactofiterativereconstructionalgorithmsoncomputedtomographytexturefeaturesoftheliverparenchymausingthefiltrationhistogrammethod
AT leejeongmin evaluationoftheimpactofiterativereconstructionalgorithmsoncomputedtomographytexturefeaturesoftheliverparenchymausingthefiltrationhistogrammethod
AT jooijin evaluationoftheimpactofiterativereconstructionalgorithmsoncomputedtomographytexturefeaturesoftheliverparenchymausingthefiltrationhistogrammethod
AT leesanghyup evaluationoftheimpactofiterativereconstructionalgorithmsoncomputedtomographytexturefeaturesoftheliverparenchymausingthefiltrationhistogrammethod
AT kimtaehyung evaluationoftheimpactofiterativereconstructionalgorithmsoncomputedtomographytexturefeaturesoftheliverparenchymausingthefiltrationhistogrammethod
AT ganeshanbalaji evaluationoftheimpactofiterativereconstructionalgorithmsoncomputedtomographytexturefeaturesoftheliverparenchymausingthefiltrationhistogrammethod