Cargando…

Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging

OBJECTIVE: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. MATERIALS AND METHODS: Thirty-seven (mean age, 71.3 ± 10 yea...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Yuehua, Yuan, Mingyuan, Yu, Mengmeng, Lu, Zhigang, Shen, Chengxing, Wang, Yining, Lu, Bin, Zhang, Jiayin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6424835/
https://www.ncbi.nlm.nih.gov/pubmed/30887744
http://dx.doi.org/10.3348/kjr.2018.0399
_version_ 1783404724190445568
author Li, Yuehua
Yuan, Mingyuan
Yu, Mengmeng
Lu, Zhigang
Shen, Chengxing
Wang, Yining
Lu, Bin
Zhang, Jiayin
author_facet Li, Yuehua
Yuan, Mingyuan
Yu, Mengmeng
Lu, Zhigang
Shen, Chengxing
Wang, Yining
Lu, Bin
Zhang, Jiayin
author_sort Li, Yuehua
collection PubMed
description OBJECTIVE: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. MATERIALS AND METHODS: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48–88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBF(ratio) was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBF(ratio) of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. RESULTS: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7–6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stent-vessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. CONCLUSION: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.
format Online
Article
Text
id pubmed-6424835
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-64248352019-04-01 Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging Li, Yuehua Yuan, Mingyuan Yu, Mengmeng Lu, Zhigang Shen, Chengxing Wang, Yining Lu, Bin Zhang, Jiayin Korean J Radiol Cardiovascular Imaging OBJECTIVE: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. MATERIALS AND METHODS: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48–88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBF(ratio) was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBF(ratio) of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. RESULTS: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7–6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stent-vessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. CONCLUSION: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose. The Korean Society of Radiology 2019-04 2019-02-25 /pmc/articles/PMC6424835/ /pubmed/30887744 http://dx.doi.org/10.3348/kjr.2018.0399 Text en Copyright © 2019 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Cardiovascular Imaging
Li, Yuehua
Yuan, Mingyuan
Yu, Mengmeng
Lu, Zhigang
Shen, Chengxing
Wang, Yining
Lu, Bin
Zhang, Jiayin
Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging
title Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging
title_full Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging
title_fullStr Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging
title_full_unstemmed Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging
title_short Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging
title_sort prevalence of decreased myocardial blood flow in symptomatic patients with patent coronary stents: insights from low-dose dynamic ct myocardial perfusion imaging
topic Cardiovascular Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6424835/
https://www.ncbi.nlm.nih.gov/pubmed/30887744
http://dx.doi.org/10.3348/kjr.2018.0399
work_keys_str_mv AT liyuehua prevalenceofdecreasedmyocardialbloodflowinsymptomaticpatientswithpatentcoronarystentsinsightsfromlowdosedynamicctmyocardialperfusionimaging
AT yuanmingyuan prevalenceofdecreasedmyocardialbloodflowinsymptomaticpatientswithpatentcoronarystentsinsightsfromlowdosedynamicctmyocardialperfusionimaging
AT yumengmeng prevalenceofdecreasedmyocardialbloodflowinsymptomaticpatientswithpatentcoronarystentsinsightsfromlowdosedynamicctmyocardialperfusionimaging
AT luzhigang prevalenceofdecreasedmyocardialbloodflowinsymptomaticpatientswithpatentcoronarystentsinsightsfromlowdosedynamicctmyocardialperfusionimaging
AT shenchengxing prevalenceofdecreasedmyocardialbloodflowinsymptomaticpatientswithpatentcoronarystentsinsightsfromlowdosedynamicctmyocardialperfusionimaging
AT wangyining prevalenceofdecreasedmyocardialbloodflowinsymptomaticpatientswithpatentcoronarystentsinsightsfromlowdosedynamicctmyocardialperfusionimaging
AT lubin prevalenceofdecreasedmyocardialbloodflowinsymptomaticpatientswithpatentcoronarystentsinsightsfromlowdosedynamicctmyocardialperfusionimaging
AT zhangjiayin prevalenceofdecreasedmyocardialbloodflowinsymptomaticpatientswithpatentcoronarystentsinsightsfromlowdosedynamicctmyocardialperfusionimaging