Cargando…

Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model

OBJECTIVE: The purpose of this study was to investigate whether three-dimensional (3D) magnetic resonance imaging could improve diagnostic accuracy for suspected posterior ligamentous complex (PLC) disruption. MATERIALS AND METHODS: We used 20 freshly harvested goat spine samples with 60 segments an...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Xuee, Wang, Jichen, Zhou, Dan, Feng, Chong, Dong, Zhiwen, Yu, Hanxiao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6424837/
https://www.ncbi.nlm.nih.gov/pubmed/30887746
http://dx.doi.org/10.3348/kjr.2018.0632
_version_ 1783404724654964736
author Zhu, Xuee
Wang, Jichen
Zhou, Dan
Feng, Chong
Dong, Zhiwen
Yu, Hanxiao
author_facet Zhu, Xuee
Wang, Jichen
Zhou, Dan
Feng, Chong
Dong, Zhiwen
Yu, Hanxiao
author_sort Zhu, Xuee
collection PubMed
description OBJECTIVE: The purpose of this study was to investigate whether three-dimensional (3D) magnetic resonance imaging could improve diagnostic accuracy for suspected posterior ligamentous complex (PLC) disruption. MATERIALS AND METHODS: We used 20 freshly harvested goat spine samples with 60 segments and intact surrounding soft tissue. The animals were aged 1–1.5 years and consisted of 8 males and 12 females, which were sexually mature but had not reached adult weights. We created a paraspinal contusion model by percutaneously injecting 10 mL saline into each side of the interspinous ligament (ISL). All segments underwent T2-weighted sagittal and coronal short inversion time inversion recovery (STIR) scans as well as coronal and sagittal 3D proton density-weighted spectrally selective inversion recovery (3D-PDW-SPIR) scans acquired at 1.5T. Following scanning, some ISLs were cut and then the segments were re-scanned using the same magnetic resonance (MR) techniques. Two radiologists independently assessed the MR images, and the reliability of ISL tear interpretation was assessed using the kappa coefficient. The chi-square test was used to compare the diagnostic accuracy of images obtained using the different MR techniques. RESULTS: The interobserver reliability for detecting ISL disruption was high for all imaging techniques (0.776–0.949). The sensitivity, specificity, and diagnostic accuracy of the coronal 3D-PDW-SPIR technique for detecting ISL tears were 100, 96.9, and 97.9%, respectively, which were significantly higher than those of the sagittal STIR (p = 0.000), coronal STIR (p = 0.000), and sagittal 3D-PDW-SPIR (p = 0.001) techniques. CONCLUSION: Compared to other MR methods, coronal 3D-PDW-SPIR provides a more accurate diagnosis of ISL disruption. Adding coronal 3D-PDW-SPIR to a routine MR protocol may help to identify PLC disruptions in cases with nearby contusion.
format Online
Article
Text
id pubmed-6424837
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-64248372019-04-01 Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model Zhu, Xuee Wang, Jichen Zhou, Dan Feng, Chong Dong, Zhiwen Yu, Hanxiao Korean J Radiol Musculoskeletal Imaging OBJECTIVE: The purpose of this study was to investigate whether three-dimensional (3D) magnetic resonance imaging could improve diagnostic accuracy for suspected posterior ligamentous complex (PLC) disruption. MATERIALS AND METHODS: We used 20 freshly harvested goat spine samples with 60 segments and intact surrounding soft tissue. The animals were aged 1–1.5 years and consisted of 8 males and 12 females, which were sexually mature but had not reached adult weights. We created a paraspinal contusion model by percutaneously injecting 10 mL saline into each side of the interspinous ligament (ISL). All segments underwent T2-weighted sagittal and coronal short inversion time inversion recovery (STIR) scans as well as coronal and sagittal 3D proton density-weighted spectrally selective inversion recovery (3D-PDW-SPIR) scans acquired at 1.5T. Following scanning, some ISLs were cut and then the segments were re-scanned using the same magnetic resonance (MR) techniques. Two radiologists independently assessed the MR images, and the reliability of ISL tear interpretation was assessed using the kappa coefficient. The chi-square test was used to compare the diagnostic accuracy of images obtained using the different MR techniques. RESULTS: The interobserver reliability for detecting ISL disruption was high for all imaging techniques (0.776–0.949). The sensitivity, specificity, and diagnostic accuracy of the coronal 3D-PDW-SPIR technique for detecting ISL tears were 100, 96.9, and 97.9%, respectively, which were significantly higher than those of the sagittal STIR (p = 0.000), coronal STIR (p = 0.000), and sagittal 3D-PDW-SPIR (p = 0.001) techniques. CONCLUSION: Compared to other MR methods, coronal 3D-PDW-SPIR provides a more accurate diagnosis of ISL disruption. Adding coronal 3D-PDW-SPIR to a routine MR protocol may help to identify PLC disruptions in cases with nearby contusion. The Korean Society of Radiology 2019-04 2019-03-11 /pmc/articles/PMC6424837/ /pubmed/30887746 http://dx.doi.org/10.3348/kjr.2018.0632 Text en Copyright © 2019 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Musculoskeletal Imaging
Zhu, Xuee
Wang, Jichen
Zhou, Dan
Feng, Chong
Dong, Zhiwen
Yu, Hanxiao
Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model
title Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model
title_full Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model
title_fullStr Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model
title_full_unstemmed Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model
title_short Coronal Three-Dimensional Magnetic Resonance Imaging for Improving Diagnostic Accuracy for Posterior Ligamentous Complex Disruption In a Goat Spine Injury Model
title_sort coronal three-dimensional magnetic resonance imaging for improving diagnostic accuracy for posterior ligamentous complex disruption in a goat spine injury model
topic Musculoskeletal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6424837/
https://www.ncbi.nlm.nih.gov/pubmed/30887746
http://dx.doi.org/10.3348/kjr.2018.0632
work_keys_str_mv AT zhuxuee coronalthreedimensionalmagneticresonanceimagingforimprovingdiagnosticaccuracyforposteriorligamentouscomplexdisruptioninagoatspineinjurymodel
AT wangjichen coronalthreedimensionalmagneticresonanceimagingforimprovingdiagnosticaccuracyforposteriorligamentouscomplexdisruptioninagoatspineinjurymodel
AT zhoudan coronalthreedimensionalmagneticresonanceimagingforimprovingdiagnosticaccuracyforposteriorligamentouscomplexdisruptioninagoatspineinjurymodel
AT fengchong coronalthreedimensionalmagneticresonanceimagingforimprovingdiagnosticaccuracyforposteriorligamentouscomplexdisruptioninagoatspineinjurymodel
AT dongzhiwen coronalthreedimensionalmagneticresonanceimagingforimprovingdiagnosticaccuracyforposteriorligamentouscomplexdisruptioninagoatspineinjurymodel
AT yuhanxiao coronalthreedimensionalmagneticresonanceimagingforimprovingdiagnosticaccuracyforposteriorligamentouscomplexdisruptioninagoatspineinjurymodel