Cargando…
The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty
PURPOSE: The aim of this study is to assess the accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty (TKA). MATERIALS AND METHODS: Twenty-seven TKAs using patient-specific instrument were reviewed. The intraoperative pin location determined by the pa...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Knee Society
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6425897/ https://www.ncbi.nlm.nih.gov/pubmed/30871288 http://dx.doi.org/10.5792/ksrr.18.038 |
_version_ | 1783404925103898624 |
---|---|
author | Kim, Kwangkyoun Kim, Jungsung Lee, Dokyoung Lim, Sohui Eom, Jiyoon |
author_facet | Kim, Kwangkyoun Kim, Jungsung Lee, Dokyoung Lim, Sohui Eom, Jiyoon |
author_sort | Kim, Kwangkyoun |
collection | PubMed |
description | PURPOSE: The aim of this study is to assess the accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty (TKA). MATERIALS AND METHODS: Twenty-seven TKAs using patient-specific instrument were reviewed. The intraoperative pin location determined by the patient-specific guide was recorded using imageless navigation software. Data recorded included tibial coronal alignment and posterior slope, femoral coronal alignment and sagittal alignment, and transepicondylar axis. A discrepancy within ±3° in each plane was considered an acceptable result. RESULTS: On the tibia, an acceptable alignment was obtained in 24 (88.1%) in the coronal plane and 21 (77.8%) in the sagittal plane. On the femur, a satisfactory alignment was obtained in 25 (92.6%) in the coronal plane and 24 (88.1%) in the sagittal plane. Based on the transepicondylar axis, a satisfactory alignment was obtained in 23 (85.1%). CONCLUSIONS: Satisfactory alignment was obtained in more than 85% of each plane of the femur and in the coronal plane of the tibia and relative to the transepicondylar axis. Sufficeint experience and precise preoperative planning are required to improve the accuracy of sagittal alignment of the tibia. |
format | Online Article Text |
id | pubmed-6425897 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Korean Knee Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-64258972019-03-27 The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty Kim, Kwangkyoun Kim, Jungsung Lee, Dokyoung Lim, Sohui Eom, Jiyoon Knee Surg Relat Res Original Article PURPOSE: The aim of this study is to assess the accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty (TKA). MATERIALS AND METHODS: Twenty-seven TKAs using patient-specific instrument were reviewed. The intraoperative pin location determined by the patient-specific guide was recorded using imageless navigation software. Data recorded included tibial coronal alignment and posterior slope, femoral coronal alignment and sagittal alignment, and transepicondylar axis. A discrepancy within ±3° in each plane was considered an acceptable result. RESULTS: On the tibia, an acceptable alignment was obtained in 24 (88.1%) in the coronal plane and 21 (77.8%) in the sagittal plane. On the femur, a satisfactory alignment was obtained in 25 (92.6%) in the coronal plane and 24 (88.1%) in the sagittal plane. Based on the transepicondylar axis, a satisfactory alignment was obtained in 23 (85.1%). CONCLUSIONS: Satisfactory alignment was obtained in more than 85% of each plane of the femur and in the coronal plane of the tibia and relative to the transepicondylar axis. Sufficeint experience and precise preoperative planning are required to improve the accuracy of sagittal alignment of the tibia. Korean Knee Society 2019-03 2019-03-01 /pmc/articles/PMC6425897/ /pubmed/30871288 http://dx.doi.org/10.5792/ksrr.18.038 Text en Copyright © 2019 Korean Knee Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Kwangkyoun Kim, Jungsung Lee, Dokyoung Lim, Sohui Eom, Jiyoon The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty |
title | The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty |
title_full | The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty |
title_fullStr | The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty |
title_full_unstemmed | The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty |
title_short | The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty |
title_sort | accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6425897/ https://www.ncbi.nlm.nih.gov/pubmed/30871288 http://dx.doi.org/10.5792/ksrr.18.038 |
work_keys_str_mv | AT kimkwangkyoun theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty AT kimjungsung theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty AT leedokyoung theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty AT limsohui theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty AT eomjiyoon theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty AT kimkwangkyoun accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty AT kimjungsung accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty AT leedokyoung accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty AT limsohui accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty AT eomjiyoon accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty |