Cargando…

The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty

PURPOSE: The aim of this study is to assess the accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty (TKA). MATERIALS AND METHODS: Twenty-seven TKAs using patient-specific instrument were reviewed. The intraoperative pin location determined by the pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Kwangkyoun, Kim, Jungsung, Lee, Dokyoung, Lim, Sohui, Eom, Jiyoon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Knee Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6425897/
https://www.ncbi.nlm.nih.gov/pubmed/30871288
http://dx.doi.org/10.5792/ksrr.18.038
_version_ 1783404925103898624
author Kim, Kwangkyoun
Kim, Jungsung
Lee, Dokyoung
Lim, Sohui
Eom, Jiyoon
author_facet Kim, Kwangkyoun
Kim, Jungsung
Lee, Dokyoung
Lim, Sohui
Eom, Jiyoon
author_sort Kim, Kwangkyoun
collection PubMed
description PURPOSE: The aim of this study is to assess the accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty (TKA). MATERIALS AND METHODS: Twenty-seven TKAs using patient-specific instrument were reviewed. The intraoperative pin location determined by the patient-specific guide was recorded using imageless navigation software. Data recorded included tibial coronal alignment and posterior slope, femoral coronal alignment and sagittal alignment, and transepicondylar axis. A discrepancy within ±3° in each plane was considered an acceptable result. RESULTS: On the tibia, an acceptable alignment was obtained in 24 (88.1%) in the coronal plane and 21 (77.8%) in the sagittal plane. On the femur, a satisfactory alignment was obtained in 25 (92.6%) in the coronal plane and 24 (88.1%) in the sagittal plane. Based on the transepicondylar axis, a satisfactory alignment was obtained in 23 (85.1%). CONCLUSIONS: Satisfactory alignment was obtained in more than 85% of each plane of the femur and in the coronal plane of the tibia and relative to the transepicondylar axis. Sufficeint experience and precise preoperative planning are required to improve the accuracy of sagittal alignment of the tibia.
format Online
Article
Text
id pubmed-6425897
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Korean Knee Society
record_format MEDLINE/PubMed
spelling pubmed-64258972019-03-27 The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty Kim, Kwangkyoun Kim, Jungsung Lee, Dokyoung Lim, Sohui Eom, Jiyoon Knee Surg Relat Res Original Article PURPOSE: The aim of this study is to assess the accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty (TKA). MATERIALS AND METHODS: Twenty-seven TKAs using patient-specific instrument were reviewed. The intraoperative pin location determined by the patient-specific guide was recorded using imageless navigation software. Data recorded included tibial coronal alignment and posterior slope, femoral coronal alignment and sagittal alignment, and transepicondylar axis. A discrepancy within ±3° in each plane was considered an acceptable result. RESULTS: On the tibia, an acceptable alignment was obtained in 24 (88.1%) in the coronal plane and 21 (77.8%) in the sagittal plane. On the femur, a satisfactory alignment was obtained in 25 (92.6%) in the coronal plane and 24 (88.1%) in the sagittal plane. Based on the transepicondylar axis, a satisfactory alignment was obtained in 23 (85.1%). CONCLUSIONS: Satisfactory alignment was obtained in more than 85% of each plane of the femur and in the coronal plane of the tibia and relative to the transepicondylar axis. Sufficeint experience and precise preoperative planning are required to improve the accuracy of sagittal alignment of the tibia. Korean Knee Society 2019-03 2019-03-01 /pmc/articles/PMC6425897/ /pubmed/30871288 http://dx.doi.org/10.5792/ksrr.18.038 Text en Copyright © 2019 Korean Knee Society This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Kwangkyoun
Kim, Jungsung
Lee, Dokyoung
Lim, Sohui
Eom, Jiyoon
The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty
title The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty
title_full The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty
title_fullStr The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty
title_full_unstemmed The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty
title_short The Accuracy of Alignment Determined by Patient-Specific Instrumentation System in Total Knee Arthroplasty
title_sort accuracy of alignment determined by patient-specific instrumentation system in total knee arthroplasty
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6425897/
https://www.ncbi.nlm.nih.gov/pubmed/30871288
http://dx.doi.org/10.5792/ksrr.18.038
work_keys_str_mv AT kimkwangkyoun theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty
AT kimjungsung theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty
AT leedokyoung theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty
AT limsohui theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty
AT eomjiyoon theaccuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty
AT kimkwangkyoun accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty
AT kimjungsung accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty
AT leedokyoung accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty
AT limsohui accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty
AT eomjiyoon accuracyofalignmentdeterminedbypatientspecificinstrumentationsystemintotalkneearthroplasty