Cargando…

Fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report

BACKGROUND: Atrial fibrillation (AF) ablation has been shown to be possible using minimal or no fluoroscopic imaging for guidance. However, the techniques previously described focus on radiofrequency ablation or rely on the use of resource-heavy technology such as intra-cardiac echocardiography. We...

Descripción completa

Detalles Bibliográficos
Autores principales: Balmforth, Damian Charles, Smith, Andrew, Schilling, Richard, O’Brien, Ben
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6426113/
https://www.ncbi.nlm.nih.gov/pubmed/31020213
http://dx.doi.org/10.1093/ehjcr/yty137
_version_ 1783404954324566016
author Balmforth, Damian Charles
Smith, Andrew
Schilling, Richard
O’Brien, Ben
author_facet Balmforth, Damian Charles
Smith, Andrew
Schilling, Richard
O’Brien, Ben
author_sort Balmforth, Damian Charles
collection PubMed
description BACKGROUND: Atrial fibrillation (AF) ablation has been shown to be possible using minimal or no fluoroscopic imaging for guidance. However, the techniques previously described focus on radiofrequency ablation or rely on the use of resource-heavy technology such as intra-cardiac echocardiography. We describe the first reported case in the literature of successful fluoroscopy-free AF cryoablation guided solely by transoesophageal echocardiography (TOE). CASE SUMMARY: A 65-year-old gentleman underwent cryoablation of paroxysmal AF using TOE guidance only with no use of fluoroscopy. Transoesophageal echocardiography was used in all stages of the procedure including guidance for transseptal puncture, ensuring balloon position in the pulmonary veins, and checking for post-procedure pericardial effusion. After 5 months of follow-up, the patient remains in sinus rhythm and has discontinued all antiarrhythmic and anticoagulant medication. DISCUSSION: This case demonstrates for the first time the feasibility of fluoroscopy-free cryoablation using only TOE for guidance.
format Online
Article
Text
id pubmed-6426113
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-64261132019-04-24 Fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report Balmforth, Damian Charles Smith, Andrew Schilling, Richard O’Brien, Ben Eur Heart J Case Rep Case Reports BACKGROUND: Atrial fibrillation (AF) ablation has been shown to be possible using minimal or no fluoroscopic imaging for guidance. However, the techniques previously described focus on radiofrequency ablation or rely on the use of resource-heavy technology such as intra-cardiac echocardiography. We describe the first reported case in the literature of successful fluoroscopy-free AF cryoablation guided solely by transoesophageal echocardiography (TOE). CASE SUMMARY: A 65-year-old gentleman underwent cryoablation of paroxysmal AF using TOE guidance only with no use of fluoroscopy. Transoesophageal echocardiography was used in all stages of the procedure including guidance for transseptal puncture, ensuring balloon position in the pulmonary veins, and checking for post-procedure pericardial effusion. After 5 months of follow-up, the patient remains in sinus rhythm and has discontinued all antiarrhythmic and anticoagulant medication. DISCUSSION: This case demonstrates for the first time the feasibility of fluoroscopy-free cryoablation using only TOE for guidance. Oxford University Press 2018-11-26 /pmc/articles/PMC6426113/ /pubmed/31020213 http://dx.doi.org/10.1093/ehjcr/yty137 Text en © The Author(s) 2018. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Reports
Balmforth, Damian Charles
Smith, Andrew
Schilling, Richard
O’Brien, Ben
Fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report
title Fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report
title_full Fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report
title_fullStr Fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report
title_full_unstemmed Fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report
title_short Fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report
title_sort fluoroscopy-free cryoablation of atrial fibrillation guided solely by transoesophageal echocardiography: a case report
topic Case Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6426113/
https://www.ncbi.nlm.nih.gov/pubmed/31020213
http://dx.doi.org/10.1093/ehjcr/yty137
work_keys_str_mv AT balmforthdamiancharles fluoroscopyfreecryoablationofatrialfibrillationguidedsolelybytransoesophagealechocardiographyacasereport
AT smithandrew fluoroscopyfreecryoablationofatrialfibrillationguidedsolelybytransoesophagealechocardiographyacasereport
AT schillingrichard fluoroscopyfreecryoablationofatrialfibrillationguidedsolelybytransoesophagealechocardiographyacasereport
AT obrienben fluoroscopyfreecryoablationofatrialfibrillationguidedsolelybytransoesophagealechocardiographyacasereport