Cargando…

Non-Contact Radiofrequency Inductive Sensor for the Dielectric Characterization of Burn Depth in Organic Tissues

A flat circular transmission line-based 300 MHz resonator was implemented for the non-contact assessment of burn depths in biological tissues. Used as a transmit-and-receive sensor, it was placed at a 2 mm distance from organic material test samples (pork fillet samples) which were previously burned...

Descripción completa

Detalles Bibliográficos
Autores principales: Dinh, Thi Hong Nhung, Serfaty, Stéphane, Joubert, Pierre-Yves
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427200/
https://www.ncbi.nlm.nih.gov/pubmed/30861994
http://dx.doi.org/10.3390/s19051220
_version_ 1783405157196759040
author Dinh, Thi Hong Nhung
Serfaty, Stéphane
Joubert, Pierre-Yves
author_facet Dinh, Thi Hong Nhung
Serfaty, Stéphane
Joubert, Pierre-Yves
author_sort Dinh, Thi Hong Nhung
collection PubMed
description A flat circular transmission line-based 300 MHz resonator was implemented for the non-contact assessment of burn depths in biological tissues. Used as a transmit-and-receive sensor, it was placed at a 2 mm distance from organic material test samples (pork fillet samples) which were previously burned on their surface in various heating conditions involving different temperatures, durations, and procedures. Data extracted from the sensor by means of a distant monitoring coil were found to clearly correlate with the depth of burn observed in the tissue samples (up to 40% sensor output changes for a 7 mm burn depth) and with the heating conditions (around 5% sensor output changes observed in samples burned with identical heating procedures but at two different temperatures—75 °C and 150 °C—and around 40% sensor output changes observed between samples heated at the same temperature but with different heating procedures). These results open the way for the development of easy-to-implement assessment and monitoring techniques for burns, e.g., integrated in wearable medical dressing-like monitoring devices.
format Online
Article
Text
id pubmed-6427200
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64272002019-04-15 Non-Contact Radiofrequency Inductive Sensor for the Dielectric Characterization of Burn Depth in Organic Tissues Dinh, Thi Hong Nhung Serfaty, Stéphane Joubert, Pierre-Yves Sensors (Basel) Article A flat circular transmission line-based 300 MHz resonator was implemented for the non-contact assessment of burn depths in biological tissues. Used as a transmit-and-receive sensor, it was placed at a 2 mm distance from organic material test samples (pork fillet samples) which were previously burned on their surface in various heating conditions involving different temperatures, durations, and procedures. Data extracted from the sensor by means of a distant monitoring coil were found to clearly correlate with the depth of burn observed in the tissue samples (up to 40% sensor output changes for a 7 mm burn depth) and with the heating conditions (around 5% sensor output changes observed in samples burned with identical heating procedures but at two different temperatures—75 °C and 150 °C—and around 40% sensor output changes observed between samples heated at the same temperature but with different heating procedures). These results open the way for the development of easy-to-implement assessment and monitoring techniques for burns, e.g., integrated in wearable medical dressing-like monitoring devices. MDPI 2019-03-11 /pmc/articles/PMC6427200/ /pubmed/30861994 http://dx.doi.org/10.3390/s19051220 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dinh, Thi Hong Nhung
Serfaty, Stéphane
Joubert, Pierre-Yves
Non-Contact Radiofrequency Inductive Sensor for the Dielectric Characterization of Burn Depth in Organic Tissues
title Non-Contact Radiofrequency Inductive Sensor for the Dielectric Characterization of Burn Depth in Organic Tissues
title_full Non-Contact Radiofrequency Inductive Sensor for the Dielectric Characterization of Burn Depth in Organic Tissues
title_fullStr Non-Contact Radiofrequency Inductive Sensor for the Dielectric Characterization of Burn Depth in Organic Tissues
title_full_unstemmed Non-Contact Radiofrequency Inductive Sensor for the Dielectric Characterization of Burn Depth in Organic Tissues
title_short Non-Contact Radiofrequency Inductive Sensor for the Dielectric Characterization of Burn Depth in Organic Tissues
title_sort non-contact radiofrequency inductive sensor for the dielectric characterization of burn depth in organic tissues
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427200/
https://www.ncbi.nlm.nih.gov/pubmed/30861994
http://dx.doi.org/10.3390/s19051220
work_keys_str_mv AT dinhthihongnhung noncontactradiofrequencyinductivesensorforthedielectriccharacterizationofburndepthinorganictissues
AT serfatystephane noncontactradiofrequencyinductivesensorforthedielectriccharacterizationofburndepthinorganictissues
AT joubertpierreyves noncontactradiofrequencyinductivesensorforthedielectriccharacterizationofburndepthinorganictissues