Cargando…

Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications

In this paper, an indirect method of measuring an analyte concentration in a test solution using the resonant frequency change of a Helmholtz resonator is proposed, using a novel architecture of Helmholtz resonator filled with two kinds of fluids (fixed fluid and test solution). Since the analyte co...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Yugang, Park, Yong-Hwa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427302/
https://www.ncbi.nlm.nih.gov/pubmed/30841646
http://dx.doi.org/10.3390/s19051127
_version_ 1783405178401062912
author Chen, Yugang
Park, Yong-Hwa
author_facet Chen, Yugang
Park, Yong-Hwa
author_sort Chen, Yugang
collection PubMed
description In this paper, an indirect method of measuring an analyte concentration in a test solution using the resonant frequency change of a Helmholtz resonator is proposed, using a novel architecture of Helmholtz resonator filled with two kinds of fluids (fixed fluid and test solution). Since the analyte concentration yields changes of density and sound speed of the test solution, the resonant frequency of the proposed Helmholtz resonator is affected by the analyte concentration of the test solution. From this effect, the analyte concentration of the test solution can be measured by the spectrum of acoustic resonance of the Helmholtz resonator. The experiment was done using a 3D-printed Helmholtz resonator system with an acoustic power source and detectors, which is consistent with analytical results and showed that the analyte concentration can be measured with higher sensitivity compared to conventional cantilever-type sensors. As an example application, the possibility of measuring glucose concentration of human blood was demonstrated, showing higher sensitivity and relatively low frequency range compared to previous resonance based methods.
format Online
Article
Text
id pubmed-6427302
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64273022019-04-15 Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications Chen, Yugang Park, Yong-Hwa Sensors (Basel) Article In this paper, an indirect method of measuring an analyte concentration in a test solution using the resonant frequency change of a Helmholtz resonator is proposed, using a novel architecture of Helmholtz resonator filled with two kinds of fluids (fixed fluid and test solution). Since the analyte concentration yields changes of density and sound speed of the test solution, the resonant frequency of the proposed Helmholtz resonator is affected by the analyte concentration of the test solution. From this effect, the analyte concentration of the test solution can be measured by the spectrum of acoustic resonance of the Helmholtz resonator. The experiment was done using a 3D-printed Helmholtz resonator system with an acoustic power source and detectors, which is consistent with analytical results and showed that the analyte concentration can be measured with higher sensitivity compared to conventional cantilever-type sensors. As an example application, the possibility of measuring glucose concentration of human blood was demonstrated, showing higher sensitivity and relatively low frequency range compared to previous resonance based methods. MDPI 2019-03-05 /pmc/articles/PMC6427302/ /pubmed/30841646 http://dx.doi.org/10.3390/s19051127 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chen, Yugang
Park, Yong-Hwa
Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications
title Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications
title_full Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications
title_fullStr Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications
title_full_unstemmed Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications
title_short Measurement of an Analyte Concentration in Test Solution by Using Helmholtz Resonator for Biosensor Applications
title_sort measurement of an analyte concentration in test solution by using helmholtz resonator for biosensor applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427302/
https://www.ncbi.nlm.nih.gov/pubmed/30841646
http://dx.doi.org/10.3390/s19051127
work_keys_str_mv AT chenyugang measurementofananalyteconcentrationintestsolutionbyusinghelmholtzresonatorforbiosensorapplications
AT parkyonghwa measurementofananalyteconcentrationintestsolutionbyusinghelmholtzresonatorforbiosensorapplications