Cargando…
Highly Responsive and Ultrasensitive Non-Enzymatic Electrochemical Glucose Sensor Based on Au Foam
Glucose concentration is an important physiological index, therefore methods for sensitive detection of glucose are important. In this study, Au foam was prepared by electrodeposition with a dynamic gas template on an Au nanoparticle/Si substrate. The Au foam showed ultrasensitivity, high selectivit...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427456/ https://www.ncbi.nlm.nih.gov/pubmed/30857279 http://dx.doi.org/10.3390/s19051203 |
_version_ | 1783405214843273216 |
---|---|
author | Shen, Nannan Xu, Haijun Zhao, Weichen Zhao, Yongmei Zhang, Xin |
author_facet | Shen, Nannan Xu, Haijun Zhao, Weichen Zhao, Yongmei Zhang, Xin |
author_sort | Shen, Nannan |
collection | PubMed |
description | Glucose concentration is an important physiological index, therefore methods for sensitive detection of glucose are important. In this study, Au foam was prepared by electrodeposition with a dynamic gas template on an Au nanoparticle/Si substrate. The Au foam showed ultrasensitivity, high selectivity, and long-term stability in the quantitative detection of glucose. The foam was used as an electrode, and the amperometric response indicated excellent catalytic activity in glucose oxidation, with a linear response across the concentration range 0.5 μM to 12 mM, and a limit of detection of 0.14 μM. High selectivity for interfering molecules at six times the normal level and long-term stability for 30 days were obtained. The results for electrochemical detection with Au foam of glucose in human serum were consistent with those obtained with a sensor based on surface-enhanced Raman spectroscopy and a commercial sensor. This proves that this method can be used with real samples. These results show that Au foam has great potential for use as a non-enzymatic glucose sensor. |
format | Online Article Text |
id | pubmed-6427456 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64274562019-04-15 Highly Responsive and Ultrasensitive Non-Enzymatic Electrochemical Glucose Sensor Based on Au Foam Shen, Nannan Xu, Haijun Zhao, Weichen Zhao, Yongmei Zhang, Xin Sensors (Basel) Article Glucose concentration is an important physiological index, therefore methods for sensitive detection of glucose are important. In this study, Au foam was prepared by electrodeposition with a dynamic gas template on an Au nanoparticle/Si substrate. The Au foam showed ultrasensitivity, high selectivity, and long-term stability in the quantitative detection of glucose. The foam was used as an electrode, and the amperometric response indicated excellent catalytic activity in glucose oxidation, with a linear response across the concentration range 0.5 μM to 12 mM, and a limit of detection of 0.14 μM. High selectivity for interfering molecules at six times the normal level and long-term stability for 30 days were obtained. The results for electrochemical detection with Au foam of glucose in human serum were consistent with those obtained with a sensor based on surface-enhanced Raman spectroscopy and a commercial sensor. This proves that this method can be used with real samples. These results show that Au foam has great potential for use as a non-enzymatic glucose sensor. MDPI 2019-03-09 /pmc/articles/PMC6427456/ /pubmed/30857279 http://dx.doi.org/10.3390/s19051203 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Shen, Nannan Xu, Haijun Zhao, Weichen Zhao, Yongmei Zhang, Xin Highly Responsive and Ultrasensitive Non-Enzymatic Electrochemical Glucose Sensor Based on Au Foam |
title | Highly Responsive and Ultrasensitive Non-Enzymatic Electrochemical Glucose Sensor Based on Au Foam |
title_full | Highly Responsive and Ultrasensitive Non-Enzymatic Electrochemical Glucose Sensor Based on Au Foam |
title_fullStr | Highly Responsive and Ultrasensitive Non-Enzymatic Electrochemical Glucose Sensor Based on Au Foam |
title_full_unstemmed | Highly Responsive and Ultrasensitive Non-Enzymatic Electrochemical Glucose Sensor Based on Au Foam |
title_short | Highly Responsive and Ultrasensitive Non-Enzymatic Electrochemical Glucose Sensor Based on Au Foam |
title_sort | highly responsive and ultrasensitive non-enzymatic electrochemical glucose sensor based on au foam |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427456/ https://www.ncbi.nlm.nih.gov/pubmed/30857279 http://dx.doi.org/10.3390/s19051203 |
work_keys_str_mv | AT shennannan highlyresponsiveandultrasensitivenonenzymaticelectrochemicalglucosesensorbasedonaufoam AT xuhaijun highlyresponsiveandultrasensitivenonenzymaticelectrochemicalglucosesensorbasedonaufoam AT zhaoweichen highlyresponsiveandultrasensitivenonenzymaticelectrochemicalglucosesensorbasedonaufoam AT zhaoyongmei highlyresponsiveandultrasensitivenonenzymaticelectrochemicalglucosesensorbasedonaufoam AT zhangxin highlyresponsiveandultrasensitivenonenzymaticelectrochemicalglucosesensorbasedonaufoam |