Cargando…
Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
Ordinal scales with low resolution are used to assess arm function in clinic. These scales may be improved by adding objective kinematic measures. The aim was to analyze within-subject, inter-rater and overall reliability (i.e., including within-subject and inter-rater reliability) and check the sys...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427602/ https://www.ncbi.nlm.nih.gov/pubmed/30870999 http://dx.doi.org/10.3390/s19051241 |
_version_ | 1783405248395608064 |
---|---|
author | Öhberg, Fredrik Bäcklund, Tomas Sundström, Nina Grip, Helena |
author_facet | Öhberg, Fredrik Bäcklund, Tomas Sundström, Nina Grip, Helena |
author_sort | Öhberg, Fredrik |
collection | PubMed |
description | Ordinal scales with low resolution are used to assess arm function in clinic. These scales may be improved by adding objective kinematic measures. The aim was to analyze within-subject, inter-rater and overall reliability (i.e., including within-subject and inter-rater reliability) and check the system’s validity of kinematic measures from inertial sensors for two such protocols on one person. Twenty healthy volunteers repeatedly performed two tasks, finger-to-nose and drinking, during two test sessions with two different raters. Five inertial sensors, on the forearms, upper arms and xiphoid process were used. Comparisons against an optical camera system evaluated the measurement validity. Cycle time, range of motion (ROM) in shoulder and elbow were calculated. Bland–Altman plots and linear mixed models including the generalizability (G) coefficient evaluated the reliability of the measures. Within-subject reliability was good to excellent in both tests (G = 0.80–0.97) and may serve as a baseline when assessing upper extremities in future patient groups. Overall reliability was acceptable to excellent (G = 0.77–0.94) for all parameters except elbow axial rotation in finger-to-nose task and both elbow axial rotation and flexion/extension in drinking task, mainly due to poor inter-rater reliability in these parameters. The low to good reliability for elbow ROM probably relates to high within-subject variability. The sensors provided good to excellent measures of cycle time and shoulder ROM in non-disabled individuals and thus have the potential to improve today’s assessment of arm function. |
format | Online Article Text |
id | pubmed-6427602 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-64276022019-04-15 Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function Öhberg, Fredrik Bäcklund, Tomas Sundström, Nina Grip, Helena Sensors (Basel) Article Ordinal scales with low resolution are used to assess arm function in clinic. These scales may be improved by adding objective kinematic measures. The aim was to analyze within-subject, inter-rater and overall reliability (i.e., including within-subject and inter-rater reliability) and check the system’s validity of kinematic measures from inertial sensors for two such protocols on one person. Twenty healthy volunteers repeatedly performed two tasks, finger-to-nose and drinking, during two test sessions with two different raters. Five inertial sensors, on the forearms, upper arms and xiphoid process were used. Comparisons against an optical camera system evaluated the measurement validity. Cycle time, range of motion (ROM) in shoulder and elbow were calculated. Bland–Altman plots and linear mixed models including the generalizability (G) coefficient evaluated the reliability of the measures. Within-subject reliability was good to excellent in both tests (G = 0.80–0.97) and may serve as a baseline when assessing upper extremities in future patient groups. Overall reliability was acceptable to excellent (G = 0.77–0.94) for all parameters except elbow axial rotation in finger-to-nose task and both elbow axial rotation and flexion/extension in drinking task, mainly due to poor inter-rater reliability in these parameters. The low to good reliability for elbow ROM probably relates to high within-subject variability. The sensors provided good to excellent measures of cycle time and shoulder ROM in non-disabled individuals and thus have the potential to improve today’s assessment of arm function. MDPI 2019-03-12 /pmc/articles/PMC6427602/ /pubmed/30870999 http://dx.doi.org/10.3390/s19051241 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Öhberg, Fredrik Bäcklund, Tomas Sundström, Nina Grip, Helena Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function |
title | Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function |
title_full | Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function |
title_fullStr | Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function |
title_full_unstemmed | Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function |
title_short | Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function |
title_sort | portable sensors add reliable kinematic measures to the assessment of upper extremity function |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427602/ https://www.ncbi.nlm.nih.gov/pubmed/30870999 http://dx.doi.org/10.3390/s19051241 |
work_keys_str_mv | AT ohbergfredrik portablesensorsaddreliablekinematicmeasurestotheassessmentofupperextremityfunction AT backlundtomas portablesensorsaddreliablekinematicmeasurestotheassessmentofupperextremityfunction AT sundstromnina portablesensorsaddreliablekinematicmeasurestotheassessmentofupperextremityfunction AT griphelena portablesensorsaddreliablekinematicmeasurestotheassessmentofupperextremityfunction |