Cargando…

Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function

Ordinal scales with low resolution are used to assess arm function in clinic. These scales may be improved by adding objective kinematic measures. The aim was to analyze within-subject, inter-rater and overall reliability (i.e., including within-subject and inter-rater reliability) and check the sys...

Descripción completa

Detalles Bibliográficos
Autores principales: Öhberg, Fredrik, Bäcklund, Tomas, Sundström, Nina, Grip, Helena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427602/
https://www.ncbi.nlm.nih.gov/pubmed/30870999
http://dx.doi.org/10.3390/s19051241
_version_ 1783405248395608064
author Öhberg, Fredrik
Bäcklund, Tomas
Sundström, Nina
Grip, Helena
author_facet Öhberg, Fredrik
Bäcklund, Tomas
Sundström, Nina
Grip, Helena
author_sort Öhberg, Fredrik
collection PubMed
description Ordinal scales with low resolution are used to assess arm function in clinic. These scales may be improved by adding objective kinematic measures. The aim was to analyze within-subject, inter-rater and overall reliability (i.e., including within-subject and inter-rater reliability) and check the system’s validity of kinematic measures from inertial sensors for two such protocols on one person. Twenty healthy volunteers repeatedly performed two tasks, finger-to-nose and drinking, during two test sessions with two different raters. Five inertial sensors, on the forearms, upper arms and xiphoid process were used. Comparisons against an optical camera system evaluated the measurement validity. Cycle time, range of motion (ROM) in shoulder and elbow were calculated. Bland–Altman plots and linear mixed models including the generalizability (G) coefficient evaluated the reliability of the measures. Within-subject reliability was good to excellent in both tests (G = 0.80–0.97) and may serve as a baseline when assessing upper extremities in future patient groups. Overall reliability was acceptable to excellent (G = 0.77–0.94) for all parameters except elbow axial rotation in finger-to-nose task and both elbow axial rotation and flexion/extension in drinking task, mainly due to poor inter-rater reliability in these parameters. The low to good reliability for elbow ROM probably relates to high within-subject variability. The sensors provided good to excellent measures of cycle time and shoulder ROM in non-disabled individuals and thus have the potential to improve today’s assessment of arm function.
format Online
Article
Text
id pubmed-6427602
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64276022019-04-15 Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function Öhberg, Fredrik Bäcklund, Tomas Sundström, Nina Grip, Helena Sensors (Basel) Article Ordinal scales with low resolution are used to assess arm function in clinic. These scales may be improved by adding objective kinematic measures. The aim was to analyze within-subject, inter-rater and overall reliability (i.e., including within-subject and inter-rater reliability) and check the system’s validity of kinematic measures from inertial sensors for two such protocols on one person. Twenty healthy volunteers repeatedly performed two tasks, finger-to-nose and drinking, during two test sessions with two different raters. Five inertial sensors, on the forearms, upper arms and xiphoid process were used. Comparisons against an optical camera system evaluated the measurement validity. Cycle time, range of motion (ROM) in shoulder and elbow were calculated. Bland–Altman plots and linear mixed models including the generalizability (G) coefficient evaluated the reliability of the measures. Within-subject reliability was good to excellent in both tests (G = 0.80–0.97) and may serve as a baseline when assessing upper extremities in future patient groups. Overall reliability was acceptable to excellent (G = 0.77–0.94) for all parameters except elbow axial rotation in finger-to-nose task and both elbow axial rotation and flexion/extension in drinking task, mainly due to poor inter-rater reliability in these parameters. The low to good reliability for elbow ROM probably relates to high within-subject variability. The sensors provided good to excellent measures of cycle time and shoulder ROM in non-disabled individuals and thus have the potential to improve today’s assessment of arm function. MDPI 2019-03-12 /pmc/articles/PMC6427602/ /pubmed/30870999 http://dx.doi.org/10.3390/s19051241 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Öhberg, Fredrik
Bäcklund, Tomas
Sundström, Nina
Grip, Helena
Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
title Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
title_full Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
title_fullStr Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
title_full_unstemmed Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
title_short Portable Sensors Add Reliable Kinematic Measures to the Assessment of Upper Extremity Function
title_sort portable sensors add reliable kinematic measures to the assessment of upper extremity function
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427602/
https://www.ncbi.nlm.nih.gov/pubmed/30870999
http://dx.doi.org/10.3390/s19051241
work_keys_str_mv AT ohbergfredrik portablesensorsaddreliablekinematicmeasurestotheassessmentofupperextremityfunction
AT backlundtomas portablesensorsaddreliablekinematicmeasurestotheassessmentofupperextremityfunction
AT sundstromnina portablesensorsaddreliablekinematicmeasurestotheassessmentofupperextremityfunction
AT griphelena portablesensorsaddreliablekinematicmeasurestotheassessmentofupperextremityfunction