Cargando…

A Novel Calibration Method of Articulated Laser Sensor for Trans-Scale 3D Measurement

The articulated laser sensor is a new kind of trans-scale and non-contact measurement instrument in regular-size space and industrial applications. These sensors overcome many deficiencies and application limitations of traditional measurement methods. The articulated laser sensor consists of two ar...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Jiehu, Wu, Bin, Duan, Xiaodeng, Xue, Ting
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427677/
https://www.ncbi.nlm.nih.gov/pubmed/30832441
http://dx.doi.org/10.3390/s19051083
_version_ 1783405265471668224
author Kang, Jiehu
Wu, Bin
Duan, Xiaodeng
Xue, Ting
author_facet Kang, Jiehu
Wu, Bin
Duan, Xiaodeng
Xue, Ting
author_sort Kang, Jiehu
collection PubMed
description The articulated laser sensor is a new kind of trans-scale and non-contact measurement instrument in regular-size space and industrial applications. These sensors overcome many deficiencies and application limitations of traditional measurement methods. The articulated laser sensor consists of two articulated laser sensing modules, and each module is made up of two rotary tables and one collimated laser. The three axes represent a non-orthogonal shaft architecture. The calibration method of system parameters for traditional instruments is no longer suitable. A novel high-accuracy calibration method of an articulated laser sensor for trans-scale 3D measurement is proposed. Based on perspective projection models and image processing techniques, the calibration method of the laser beam is the key innovative aspect of this study and is introduced in detail. The experimental results show that a maximum distance error of 0.05 mm was detected with the articulated laser sensor. We demonstrate that the proposed high-accuracy calibration method is feasible and effective, particularly for the calibration of laser beams.
format Online
Article
Text
id pubmed-6427677
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-64276772019-04-15 A Novel Calibration Method of Articulated Laser Sensor for Trans-Scale 3D Measurement Kang, Jiehu Wu, Bin Duan, Xiaodeng Xue, Ting Sensors (Basel) Article The articulated laser sensor is a new kind of trans-scale and non-contact measurement instrument in regular-size space and industrial applications. These sensors overcome many deficiencies and application limitations of traditional measurement methods. The articulated laser sensor consists of two articulated laser sensing modules, and each module is made up of two rotary tables and one collimated laser. The three axes represent a non-orthogonal shaft architecture. The calibration method of system parameters for traditional instruments is no longer suitable. A novel high-accuracy calibration method of an articulated laser sensor for trans-scale 3D measurement is proposed. Based on perspective projection models and image processing techniques, the calibration method of the laser beam is the key innovative aspect of this study and is introduced in detail. The experimental results show that a maximum distance error of 0.05 mm was detected with the articulated laser sensor. We demonstrate that the proposed high-accuracy calibration method is feasible and effective, particularly for the calibration of laser beams. MDPI 2019-03-03 /pmc/articles/PMC6427677/ /pubmed/30832441 http://dx.doi.org/10.3390/s19051083 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kang, Jiehu
Wu, Bin
Duan, Xiaodeng
Xue, Ting
A Novel Calibration Method of Articulated Laser Sensor for Trans-Scale 3D Measurement
title A Novel Calibration Method of Articulated Laser Sensor for Trans-Scale 3D Measurement
title_full A Novel Calibration Method of Articulated Laser Sensor for Trans-Scale 3D Measurement
title_fullStr A Novel Calibration Method of Articulated Laser Sensor for Trans-Scale 3D Measurement
title_full_unstemmed A Novel Calibration Method of Articulated Laser Sensor for Trans-Scale 3D Measurement
title_short A Novel Calibration Method of Articulated Laser Sensor for Trans-Scale 3D Measurement
title_sort novel calibration method of articulated laser sensor for trans-scale 3d measurement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6427677/
https://www.ncbi.nlm.nih.gov/pubmed/30832441
http://dx.doi.org/10.3390/s19051083
work_keys_str_mv AT kangjiehu anovelcalibrationmethodofarticulatedlasersensorfortransscale3dmeasurement
AT wubin anovelcalibrationmethodofarticulatedlasersensorfortransscale3dmeasurement
AT duanxiaodeng anovelcalibrationmethodofarticulatedlasersensorfortransscale3dmeasurement
AT xueting anovelcalibrationmethodofarticulatedlasersensorfortransscale3dmeasurement
AT kangjiehu novelcalibrationmethodofarticulatedlasersensorfortransscale3dmeasurement
AT wubin novelcalibrationmethodofarticulatedlasersensorfortransscale3dmeasurement
AT duanxiaodeng novelcalibrationmethodofarticulatedlasersensorfortransscale3dmeasurement
AT xueting novelcalibrationmethodofarticulatedlasersensorfortransscale3dmeasurement