Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems

BACKGROUND AND PURPOSE: Although the clock drawing test (CDT) is a widely used cognitive screening instrument, there have been inconsistent findings regarding its utility with various scoring systems in patients with mild cognitive impairment (MCI) or dementia. The present study aimed to identify wh...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Sangsoon, Jahng, Seungmin, Yu, Kyung-Ho, Lee, Byung-Chul, Kang, Yeonwook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Dementia Association 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6428010/
https://www.ncbi.nlm.nih.gov/pubmed/30906399
http://dx.doi.org/10.12779/dnd.2018.17.3.100
_version_ 1783405337299124224
author Kim, Sangsoon
Jahng, Seungmin
Yu, Kyung-Ho
Lee, Byung-Chul
Kang, Yeonwook
author_facet Kim, Sangsoon
Jahng, Seungmin
Yu, Kyung-Ho
Lee, Byung-Chul
Kang, Yeonwook
author_sort Kim, Sangsoon
collection PubMed
description BACKGROUND AND PURPOSE: Although the clock drawing test (CDT) is a widely used cognitive screening instrument, there have been inconsistent findings regarding its utility with various scoring systems in patients with mild cognitive impairment (MCI) or dementia. The present study aimed to identify whether patients with MCI or dementia exhibited impairment on the CDT using three different scoring systems, and to determine which scoring system is more useful for detecting MCI and mild dementia. METHODS: Patients with amnestic mild cognitive impairment (aMCI), vascular mild cognitive impairment (VaMCI), mild Alzheimer's disease (AD), mild vascular dementia (VaD), and cognitively normal older adults (CN) were included. All participants were administered the CDT, the Korean-Mini Mental State Examination (K-MMSE), and the Clinical Dementia Rating scale. The CDT was scored using the 3-, 5-, and 15-point scoring systems. RESULTS: On all three scoring systems, all patient groups demonstrated significantly lower scores than the CN. However, while there were no significant differences among patients with aMCI, VaMCI, and AD, those with VaD exhibited the lowest scores. Area under the Receiver Operating Characteristic curves revealed that the three CDT scoring systems were comparable with the K-MMSE in differentiating aMCI, VaMCI, and VaD from CN. In differentiating AD from CN, however, the CDT using the 15-point scoring system demonstrated the most comparable discriminability with K-MMSE. CONCLUSIONS: The results demonstrated that the CDT is a useful cognitive screening tool that is comparable with the Mini-Mental State Examination, and that simple CDT scoring systems are sufficient for differentiating patients with MCI and mild dementia from CN.
format Online
Article
Text
id pubmed-6428010
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Korean Dementia Association
record_format MEDLINE/PubMed
spelling pubmed-64280102019-03-22 Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems Kim, Sangsoon Jahng, Seungmin Yu, Kyung-Ho Lee, Byung-Chul Kang, Yeonwook Dement Neurocogn Disord Original Article BACKGROUND AND PURPOSE: Although the clock drawing test (CDT) is a widely used cognitive screening instrument, there have been inconsistent findings regarding its utility with various scoring systems in patients with mild cognitive impairment (MCI) or dementia. The present study aimed to identify whether patients with MCI or dementia exhibited impairment on the CDT using three different scoring systems, and to determine which scoring system is more useful for detecting MCI and mild dementia. METHODS: Patients with amnestic mild cognitive impairment (aMCI), vascular mild cognitive impairment (VaMCI), mild Alzheimer's disease (AD), mild vascular dementia (VaD), and cognitively normal older adults (CN) were included. All participants were administered the CDT, the Korean-Mini Mental State Examination (K-MMSE), and the Clinical Dementia Rating scale. The CDT was scored using the 3-, 5-, and 15-point scoring systems. RESULTS: On all three scoring systems, all patient groups demonstrated significantly lower scores than the CN. However, while there were no significant differences among patients with aMCI, VaMCI, and AD, those with VaD exhibited the lowest scores. Area under the Receiver Operating Characteristic curves revealed that the three CDT scoring systems were comparable with the K-MMSE in differentiating aMCI, VaMCI, and VaD from CN. In differentiating AD from CN, however, the CDT using the 15-point scoring system demonstrated the most comparable discriminability with K-MMSE. CONCLUSIONS: The results demonstrated that the CDT is a useful cognitive screening tool that is comparable with the Mini-Mental State Examination, and that simple CDT scoring systems are sufficient for differentiating patients with MCI and mild dementia from CN. Korean Dementia Association 2018-09 2018-12-09 /pmc/articles/PMC6428010/ /pubmed/30906399 http://dx.doi.org/10.12779/dnd.2018.17.3.100 Text en © 2018 Korean Dementia Association https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Sangsoon
Jahng, Seungmin
Yu, Kyung-Ho
Lee, Byung-Chul
Kang, Yeonwook
Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems
title Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems
title_full Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems
title_fullStr Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems
title_full_unstemmed Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems
title_short Usefulness of the Clock Drawing Test as a Cognitive Screening Instrument for Mild Cognitive Impairment and Mild Dementia: an Evaluation Using Three Scoring Systems
title_sort usefulness of the clock drawing test as a cognitive screening instrument for mild cognitive impairment and mild dementia: an evaluation using three scoring systems
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6428010/
https://www.ncbi.nlm.nih.gov/pubmed/30906399
http://dx.doi.org/10.12779/dnd.2018.17.3.100
work_keys_str_mv AT kimsangsoon usefulnessoftheclockdrawingtestasacognitivescreeninginstrumentformildcognitiveimpairmentandmilddementiaanevaluationusingthreescoringsystems
AT jahngseungmin usefulnessoftheclockdrawingtestasacognitivescreeninginstrumentformildcognitiveimpairmentandmilddementiaanevaluationusingthreescoringsystems
AT yukyungho usefulnessoftheclockdrawingtestasacognitivescreeninginstrumentformildcognitiveimpairmentandmilddementiaanevaluationusingthreescoringsystems
AT leebyungchul usefulnessoftheclockdrawingtestasacognitivescreeninginstrumentformildcognitiveimpairmentandmilddementiaanevaluationusingthreescoringsystems
AT kangyeonwook usefulnessoftheclockdrawingtestasacognitivescreeninginstrumentformildcognitiveimpairmentandmilddementiaanevaluationusingthreescoringsystems